SolaX Power Triple Power T-BAT-SYS-HV 5.8 (T58)
Official manufacturer global verified Aug. 31, 2026
Product-page hero image, visually verified as a product photo of the T-BAT stack
Identity
| category | batteries |
| ean | UNKNOWN |
| generation | V3 |
| manufacturer | Solax Power |
| market_version | UNKNOWN |
| model | Triple Power T-BAT-SYS-HV 5.8 (T58) |
| mpn | T-BAT H 5.8(H) V3 (module) / HV11550(H) V3 (BMS) |
| product_family | SolaX Triple Power T-BAT-SYS-HV (T58) high-voltage stack; BMS unit HV11550(H) V3 plus 1-5 x T-BAT H 5.8 modules |
| product_revision | V3 (HV11550(H) V3 BMS; T-BAT H 5.8(H) V3 modules) |
| product_status | active |
| region | global |
| release_year | UNKNOWN |
| sku | UNKNOWN |
| system_range | T-BAT H 5.8(H) V3 through T-BAT H 34.6(H) V3 (5.8 kWh ~ 34.6 kWh) |
Electrical
| chemistry | LFP |
| communication_can | True |
| communication_rs485 | True |
| firmware_requirements | UNKNOWN |
| max_continuous_charge_current_a | 25 |
| max_continuous_discharge_current_a | 25 |
| max_continuous_power_kw | 2.9 |
| max_parallel_units | 12 (datasheet: 'Max expandable to 12 units with 69.1kWh capacity' with dual-port inverters) |
| max_series_units | 5 |
| min_series_units_hv | 1 |
| nominal_energy_kwh | 5.8 |
| nominal_voltage_v | 115.2 |
| officially_supported_inverter_brands | ['SolaX Power'] |
| officially_supported_inverter_models | ['HV11550(H) V3'] |
| peak_current_a | 35 |
| supported_inverter_protocols | ['CAN 2.0', 'RS485'] |
| usable_energy_kwh | 5.5 |
| voltage_class | HV |
| voltage_range_v | 100-130 |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | UNKNOWN |
| depth_mm | 150 |
| dimension_note | Datasheet row reads 'Dimension (W*H*D) 474 x 715 x 150 mm' for all modules; the installation manual's dimension drawing shows 707 mm across, 474 mm, 150 mm and a 715 mm overall figure - see data_conflicts |
| enclosure_material | UNKNOWN |
| height_mm | 715 |
| housing_color | UNKNOWN |
| mounting_bolt_size | M8 expansion bolt x2 (wall/floor bracket); M6x14 external hexagon combination bolt x2; M5 ground screw |
| mounting_hole_diameter_mm | 10 |
| mounting_hole_spacing_mm | vertical spacing between stacked units 240-320 mm (recommended 280 mm) |
| mounting_plate_dimensions_mm | UNKNOWN |
| mounting_type | ['wall', 'floor'] |
| screw_sizes | M8, M6, M5 |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | power cable connectors, 8-pin communication connectors (RS485 A/B), PE terminal, POWER button, heat port (heating models) |
| torque_specs |
M8 expansion bolt 15 +/- 1 N.m; M6x14 combination bolt 3 +/- 0.3 N.m; M5 ground connection 1.0 +/- 0.1 N.m
T-BAT-SYS-HV-5.8 Installation Manual Version 3.0 — installation manual mounting section: M8 15 +/- 1 N.m, M6 3 +/- 0.3 N.m, ground M5 1.0 +/- 0.1 N.m
|
| weight_kg | 59.5 +/- 1 (battery module); 61.5 +/- 1 (BMS unit) |
| width_mm | 474 |
Installation
| altitude_derating_note | UNKNOWN |
| clearance_bottom_mm | UNKNOWN |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm | UNKNOWN |
| clearance_right_mm | UNKNOWN |
| clearance_top_mm | UNKNOWN |
| cooling_airflow_requirements | natural cooling |
| direct_sunlight_restriction | avoid direct sunlight - 'Exposure to direct sunlight raises temperature inside battery'; also avoid rain, snow, combustibles, antennas, explosives and corrosives |
| drill_hole_depth_mm | > 50 |
| drill_hole_diameter_mm | 10 |
| indoor_outdoor | IP66; avoid direct sunlight, rain and snow |
| installation_humidity_range | 4 ~ 100 %RH |
| installation_temperature_range_c | -30 ~ +55 |
| load_bearing_requirement | bearing capacity >= (BMS weight + battery weight x 2) x 4 |
| max_installation_altitude_m | 2000 |
| minimum_wall_run_mm | 610 for a single BMS (wall mounting); 540 for floor mounting |
| minimum_wall_thickness_mm |
100
T-BAT-SYS-HV-5.8 Installation Manual Version 3.0 — installation manual: 'Solid brick or concrete wall with a minimum thickness of 100 mm'
|
| mounting_orientation | upright; wall-mounted or floor-mounted stack |
| orientation_allowed | ['wall mounting', 'floor mounting'] |
| orientation_forbidden | UNKNOWN |
| surface_requirements | solid brick or concrete wall with a minimum thickness of 100 mm; for floor mounting a 30-40 mm cushion (foam or similar) beneath the unit |
| two_person_lift_required | UNKNOWN (module mass 59.5-61.5 kg) |
| unit_vertical_spacing_mm | 240-320 (recommended 280) |
| ventilation_requirements | UNKNOWN |
Environment
| cooling_method | natural |
| corrosion_class | UNKNOWN |
| fan_replaceable | N/A (natural cooling) |
| heating_option | optional integrated heating ('H' models) extends the charge/discharge window down to -30 C |
| ik_rating | UNKNOWN |
| ip_rating |
IP66
SolaX T-BAT-SYS-HV-5.8 (T58) Datasheet (EN) — datasheet row 'IP66'; installation manual environment block 'IP66 -30 C +55 C, 4-100%RH, 2000 m'
|
| max_altitude_m | 2000 |
| nema_rating | UNKNOWN |
| noise_level_db | UNKNOWN |
| operating_temperature_c |
charge 0 ~ 55 (heating off) / -30 ~ 55 (heating on); discharge -20 ~ 55 (heating off) / -30 ~ 55 (heating on)
SolaX T-BAT-SYS-HV-5.8 (T58) Datasheet (EN) — datasheet charge/discharge temperature rows including the heating-on/off cases
|
| pollution_degree | UNKNOWN |
| relative_humidity | 4 ~ 100 % (Condensing) |
| salt_mist_resistance | UNKNOWN |
| storage_temperature_c | -20 ~ 30 (12 months) / 30 ~ 55 (6 months) |
| uv_resistance | UNKNOWN |
Interfaces & connectors
| battery_terminal_type | supplied power cables, 'B2ca' rated - 2 m in the BMS kit, 670 mm between battery packs |
| bluetooth | UNKNOWN |
| can | yes (CAN 2.0) |
| comms_connector | 8-pin connectors carrying RS485 A/B |
| ethernet | UNKNOWN |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| protocol_notes | Datasheet communication row: 'CAN 2.0 + RS485' |
| rs485 | yes |
| usb | UNKNOWN |
| wifi | UNKNOWN |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | POWER button (press ~3 seconds to switch on/off) |
| display_type | none (LED indicators only) |
| leds | Status LED - red/green alternating (on), green 1 s / off 4 s (standby), yellow (off), red (fault); S1 LED on each battery pack; 4 SOC LEDs indicating state-of-charge ranges |
| local_display | False |
| mobile_app | UNKNOWN |
| remote_display_option | UNKNOWN |
| status_indicators | SOC indication via 4 LEDs |
| touchscreen | False |
| web_interface | UNKNOWN |
Protection
| communication_loss_detection | yes (red LED for 10 minutes, then a 1 s on / 4 s off cycle) |
| over_current | UNKNOWN |
| over_temperature | UNKNOWN |
| over_voltage | UNKNOWN |
| protection_class | UNKNOWN |
| reverse_polarity | UNKNOWN |
| short_circuit | UNKNOWN |
| under_voltage | UNKNOWN |
Certifications
| emc | ['IEC61000-1', 'IEC61000-3'] |
| grid_codes | [] |
| other | ['UN38.3'] |
| regional | ['VDE2510'] |
| safety |
['IEC62619', 'IEC63056', 'IEC60730', 'IEC62040', 'EN62477']
SolaX T-BAT-SYS-HV-5.8 (T58) Datasheet (EN) — datasheet certification row 'IEC62619 / IEC63056 / IEC60730 / IEC62040 / IEC61000-1&-3 / EN62477 / VDE2510'
|
Warranty & service
| conditions | UNKNOWN |
| cycle_life |
> 6000 Cycles (95% DOD)
SolaX T-BAT-SYS-HV-5.8 (T58) Datasheet (EN) — datasheet row 'Cycle Life (95% DOD) > 6000 Cycles'
|
| design_life_years | 10 |
| extended_options_years | UNKNOWN |
| field_replaceable_parts | UNKNOWN |
| service_intervals | UNKNOWN |
| standard_years |
10
SolaX T-BAT-SYS-HV-5.8 (T58) Datasheet (EN) — datasheet rows 'Design Life 10 Years' and 'Warranty 10 Years'
|
Packaging & logistics
| gross_weight_kg | UNKNOWN |
| package_depth_mm | UNKNOWN |
| package_height_mm | UNKNOWN |
| package_width_mm | UNKNOWN |
| transport_restrictions |
UN38.3, Class 9 dangerous goods
SolaX T-BAT-SYS-HV-5.8 (T58) Datasheet (EN) — datasheet transport row 'Class 9' / 'UN38.3'
|
| units_per_pallet | UNKNOWN |
Documents
Recorded conflicts
physical dimensions Review required
474 x 715 x 150 mm (W*H*D, all modules) — official T58 datasheet dimension row
dimension drawing showing 707 mm, 474 mm, 150 mm and a 715 mm overall figure — official T-BAT-SYS-HV-5.8 Installation Manual Version 3.0
the datasheet row and the manual drawing appear to use different axis orders and/or measure the BMS+pack assembly rather than a single module; not resolved
physical dimensions Review required
474 x 715 x 150 mm (W*H*D, all modules) — official T58 datasheet dimension row
dimension drawing showing 707 mm, 474 mm, 150 mm and a 715 mm overall figure — official T-BAT-SYS-HV-5.8 Installation Manual Version 3.0
the datasheet row and the manual drawing appear to use different axis orders and/or measure the BMS+pack assembly rather than a single module; not resolved
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| BMS stacking restriction | Avoid configuring HV11550/HV11550 V2 as 4th or 5th |
| Depth of Discharge | 95 % |
| Load bearing requirement | Bearing capacity >= (BMS weight + battery weight x 2) x 4 |
| Max charge/discharge current | 25 A standard, 35 A max |
| Max power | 2.9 kW rated, 4 kW max |
| PE cable | 6 mm2 recommended |