ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseBattery Control Units

Dyness Tower BDU control module (ES-BC-EU)

Verified distributor global (EN documentation) verified Sept. 2, 2026

Identity

category battery_control_units
ean UNKNOWN
generation UNKNOWN
hardware_revision UNKNOWN
legacy_name UNKNOWN
manufacturer Dyness (Dyness Digital Energy Technology Co., LTD)
market_version EN
model Tower BDU control module (ES-BC-EU)
mpn ES-BC-EU
product_family Dyness Tower (T7-T21) system components
product_status UNKNOWN
product_status_detail current
product_status_evidence Stocked and listed by the EU distributor 7SUN (57 units in stock) as of 2026-09-02; the Tower series it serves has a live official product page.
region global (EN documentation)
release_year UNKNOWN
sku UNKNOWN
subcategory battery control unit / BDU for a stacked high-voltage battery tower (stack BMS + DC breaker + external DC terminals + inverter communication port)
variant_note CONTROL UNIT only - no stored energy. The part designation 'ES-BC-EU' comes from the 7SUN distributor listing 'Control module - DYNESS - BDU - ES-BC-EU'; it is not printed in the fetched Dyness user manual. Pairs with 2-6 HV9637 modules to form a Tower T7/T10/T14/T17/T21.

Electrical

cell_chemistry UNKNOWN
cell_type UNKNOWN
continuous_charge_current_a 18.5
continuous_discharge_current_a 18.5
continuous_power_kw UNKNOWN
cycle_life UNKNOWN
depth_of_discharge_pct UNKNOWN
max_charge_current_a 37
max_charge_power_kw UNKNOWN
max_discharge_current_a 37
max_discharge_power_kw UNKNOWN
max_parallel_units 12
max_series_units 6
modules_per_tower_max 6
modules_per_tower_min 2
nominal_capacity_ah UNKNOWN
nominal_energy_kwh NOT APPLICABLE - control unit, stores no energy
nominal_voltage_v UNKNOWN
operating_voltage_max_v 657
operating_voltage_min_v 168
parallel_supported True
peak_charge_current_a UNKNOWN
peak_discharge_current_a UNKNOWN
peak_power_kw UNKNOWN
round_trip_efficiency_pct UNKNOWN
series_supported True
system_energy_max_kwh 21.31
system_energy_min_kwh 7.1
usable_energy_kwh NOT APPLICABLE - control unit, stores no energy

Physical / mechanical

color UNKNOWN
cooling_method UNKNOWN
depth_mm UNKNOWN
enclosure_material UNKNOWN
height_mm UNKNOWN
installation_notes 7SUN lists the control module weight as 25.5 kg. Its dimensions are not published separately; the tower footprint is 504 x 380 mm.
ip_rating IP54 (tower system level)
mounting_type mounted on top of the stacked HV9637 modules
rack_units UNKNOWN
shipping_weight_kg UNKNOWN
weight_kg 25.5
width_mm UNKNOWN

Installation

indoor_outdoor installed at the top of the tower stack, inside the tower enclosure
notes Mandatory: exactly one control unit per tower, plus a base at the bottom of the stack. It stores no energy - all energy figures belong to the battery modules and to the assembled tower system.
parallel_hub_required False

Environment

indoor_outdoor inside the tower enclosure (IP54)
max_altitude_m UNKNOWN
operating_humidity UNKNOWN
operating_temperature_charge_max_c UNKNOWN
operating_temperature_charge_min_c UNKNOWN
operating_temperature_discharge_max_c UNKNOWN
operating_temperature_discharge_min_c UNKNOWN
operating_temperature_max_c UNKNOWN
operating_temperature_min_c UNKNOWN
pollution_degree UNKNOWN
storage_humidity UNKNOWN
storage_temperature_max_c UNKNOWN
storage_temperature_min_c UNKNOWN

Interfaces & connectors

bluetooth UNKNOWN
can True
communication_ports 'EXT-CAN/RS485' RJ45 to the inverter; 9-pin BDU port to the module stack; parallel ports for multi-cluster
dry_contact UNKNOWN
ethernet UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
protocol_notes EXT-CAN/RS485 pinout: PIN1 Orange/White 485_A, PIN2 Orange 485_B, PIN3 Green/White Reserved, PIN4 Blue CANH, PIN5 Blue/White CANL, PIN6 Green CANIN, PIN7 Brown/White CANOUT, PIN8 Brown NC. BDU port definition: 1 Negative output, 2 Positive output, 3 SWAKE, 4 SCANSG, 5 SCANL, 6 SCANH, 7 24V-, 8 24V+, 9 SCANOUT.
rs232 Datasheet-level 'CAN/RS485/RS232' claim; only CAN/RS485 pins are documented on the EXT port
rs485 True
usb UNKNOWN
wifi UNKNOWN

Protection

fire_suppression UNKNOWN
notes Tower manual protection chapter requires a 30-minute wait before resetting a tripped DC breaker.
overcurrent Integrated DC breaker (master switch / short-circuit protection)

Certifications

emc_certifications CE-EMC
safety_certifications IEC62619 / IEC63056 / IEC62477 / IEC62040 / IEC60730 / VDE2510-50 / UL1973 / UKCA
standards UN38.3/CE-EMC/IEC62040/IEC62619/IEC62477/IEC60730/IEC63056/UKCA/CEC Accredited/UL1973/VDE2510-50 (quoted at Tower system level)
transport_certifications UN38.3

Warranty & service

conditions UNKNOWN
summary 7SUN distributor listing: 'Warranty: 10 years'.
years 10

Documents

compatibility_list List of the Inverter Brands Compatible with Dyness Tower Series, last updated 06/05/2025 - distributor mirror on vanmeenen.com rev 250506
datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Dyness Tower datasheet EN 2025-04-22 (TowerDatasheetEN20250422-281.pdf) - official, linked from the Tower product page — located, not retrieved rev 2025-04-22
datasheet Dyness Tower datasheet-EN V1.0-20230704 - distributor mirror on estsolar.lt rev V1.0-20230704
distributor_listing 7SUN distributor listing: Control module - DYNESS - BDU - ES-BC-EU rev UNKNOWN
product_page Dyness Tower T14 product page on dyness.us (official Dyness USA store) rev UNKNOWN
product_page Dyness Tower official product page (HTML, dyness.com without www) rev UNKNOWN
retailer_article ONSA Plus retailer blog: 'The Dyness Tower is ending: move to Tower Pro and Stack' (published 30.06.2026) rev UNKNOWN
user_manual Tower USER MANUAL HV Battery System Tower - T7/T10/T14/T17/T21 192-576V (Tower 1.5g User Manual-EN) - distributor mirror on cdn.prod.website-files.com rev Tower 1.5g / V1

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

7SUN distributor internal SKU / EANSKU F12B2, EAN 2010000029497 (20-prefix restricted-circulation code, distributor internal barcode)
7SUN listed price327.33 EUR gross
Base (separate mandatory item)Tower base 504 x 380 x 186 mm, counted separately from the modules and the BDU. NOTE: this dimension is carried over from the existing ANMA canonical Tower T14 record (a prior agent's reading of the same Tower 1.5g user manual); it was NOT returned by this session's fetch of that manual, so treat it as unconfirmed in this batch.
WAKE signalling'SWAKE' pin on the BDU port and composite connectors
identity.product_statuscurrent
manufacturer_legal_entity_as_printedDyness Digital Energy Technology Co., LTD