Electrical
| battery_voltage_range_vdc |
9 - 60 VDC
|
| contactor_continuous_rating_a |
1000
|
| contactor_peak_rating |
1200 A for 5 minutes
|
| power_consumption_off_mode |
0.3 mA for all system voltages
|
| power_consumption_on_mode |
Approximately 4.2 W (350 mA at 12 V)
|
| power_consumption_standby |
Approximately 0.6 W (50 mA at 12 V)
|
| pre_charge_minimum_load |
10 Ω and above for 12 V; 20 Ω and above for 24 V and 48 V
|
| reverse_polarity_protection |
No
|
| supply_voltage_range_vdc |
9 - 60 Vdc
|
| supported_system_voltages_v |
12, 24 or 48 V
|
Physical / mechanical
| busbar_dimensions_mm |
8 x 30
|
| busbar_material |
Tinned copper
|
| busbar_terminals |
M10
|
| busbar_torque |
33 Nm
|
| depth_mm |
100
|
| dimensions_h_w_d_mm |
230 x 180 x 100
|
| enclosure_material |
ABS
|
| height_mm |
230
|
| weight_kg |
2.7
|
| width_mm |
180
|
Installation
| lynx_distributor_modules |
Up to 4 Lynx Distributor modules via RJ10
|
| max_batteries_supported |
20
|
| max_energy_storage |
up to 84 kWh in a 12 V system
|
| supported_battery_types |
Victron Lithium Smart batteries (LiFePO4 12,8 V / 25,6 V)
|
Environment
| humidity_non_condensing |
Max. 95 %
|
| operating_temperature |
-40 °C to +60 °C
|
| protection_class_ip |
IP22
|
| storage_temperature |
-40 °C to +60 °C
|
Interfaces & connectors
| battery_bms_connector |
M8 circular 3-pole battery connectors (male + female)
|
| bluetooth |
Bluetooth for VictronConnect app
|
| bms_can |
UNKNOWN
|
| io_connector |
Removable multi-connector
|
| lynx_distributor_link |
RJ10
|
| nmea2000 |
NMEA 2000 capable
|
| ve_bus |
UNKNOWN
|
| ve_can |
RJ45 VE.Can ports (with RJ45 terminator)
|
| ve_direct |
UNKNOWN
|
Protection
| allow_to_charge_output |
0.5 A at 60 Vdc, protected by resettable fuse
|
| allow_to_discharge_output |
0.5 A at 60 Vdc, protected by resettable fuse
|
| aux_output |
1.1 A continuous, protected by resettable fuse
|
| battery_monitor |
Integrated battery monitor displaying state of charge percentage
|
| contactor_function |
Built-in 1000 A contactor as fallback safety mechanism and remote-controllable main switch
|
| dvcc |
DVCC compatible
|
| pre_alarm |
Pre-alarm signal capability (documented on product page)
|
| programmable_relay_spdt |
2 A at 60 Vdc
|
Certifications
| standards |
['EN-IEC 63000:2018', 'EN-IEC 61000-6-3:2007/A1:2011/AC:2012', 'NEN-EN-ISO 9001:2015']
|
Documents
installation-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Smart BMS 1000A (M10) enclosure dimensions — located, not retrieved
user-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Smart BMS rev 17 - 01/2026 (PDF) — located, not retrieved
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Busbar | Tinned copper, 8 x 30mm |
| Power (OFF mode) | 0.3mA for all system voltages |
Build a system with this product