ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseBattery Management Systems

Victron Energy Lynx Smart BMS 500

Official manufacturer global verified Sept. 2, 2026

Identity

category battery_management_systems
manufacturer Victron Energy B.V.
model Lynx Smart BMS 500
product_family Lynx Smart BMS
product_status active
region global
sku UNKNOWN

Electrical

battery_voltage_range_vdc 9 - 60 VDC
contactor_continuous_rating_a 500
contactor_peak_rating 600 A for 5 minutes
power_consumption_off_mode 0.3 mA for all system voltages
power_consumption_on_mode Approximately 2.6 W (217 mA at 12 V)
power_consumption_standby Approximately 0.6 W (50 mA at 12 V)
pre_charge_minimum_load 10 Ω and above for 12 V; 20 Ω and above for 24 V and 48 V
reverse_polarity_protection No
supply_voltage_range_vdc 9 - 60 Vdc
supported_system_voltages_v 12, 24 or 48 V

Physical / mechanical

busbar_dimensions_mm 8 x 30
busbar_material Tinned copper
busbar_terminals M10
busbar_torque 33 Nm
depth_mm 80
dimensions_h_w_d_mm 190 x 180 x 80
enclosure_material ABS
height_mm 190
weight_kg 1.9
width_mm 180

Installation

lynx_distributor_modules Up to 4 Lynx Distributor modules via RJ10
max_batteries_supported 20
max_energy_storage up to 84 kWh in a 12 V system
supported_battery_types Victron Lithium Smart batteries (LiFePO4 12,8 V / 25,6 V)

Environment

humidity_non_condensing Max. 95 %
operating_temperature -40 °C to +60 °C
protection_class_ip IP22
storage_temperature -40 °C to +60 °C

Interfaces & connectors

battery_bms_connector M8 circular 3-pole battery connectors (male + female)
bluetooth Bluetooth for VictronConnect app
bms_can UNKNOWN
io_connector Removable multi-connector
lynx_distributor_link RJ10
nmea2000 NMEA 2000 capable
ve_bus UNKNOWN
ve_can RJ45 VE.Can ports (with RJ45 terminator)
ve_direct UNKNOWN

Protection

allow_to_charge_output 0.5 A at 60 Vdc, protected by resettable fuse
allow_to_discharge_output 0.5 A at 60 Vdc, protected by resettable fuse
aux_output 1.1 A continuous, protected by resettable fuse
battery_monitor Integrated battery monitor displaying state of charge percentage
contactor_function Built-in contactor functioning as fallback safety mechanism and remote-controllable main switch
dvcc DVCC compatible
pre_alarm Pre-alarm signal capability (documented on product page; not itemised as a spec row)
programmable_relay_spdt 2 A at 60 Vdc

Certifications

standards ['EN-IEC 63000:2018', 'EN-IEC 61000-6-3:2007/A1:2011/AC:2012', 'NEN-EN-ISO 9001:2015']

Warranty & service

summary UNKNOWN

Documents

datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} BMS overview — located, not retrieved
datasheet Lynx Smart BMS
installation-manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Lynx Smart BMS 500 enclosure dimensions — located, not retrieved
user-manual Lithium Battery Smart manual - 3. System design and BMS selection guide
user-manual Lynx Smart BMS manual - Technical specifications
user-manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Lynx Smart BMS rev 17 - 01/2026 (PDF) — located, not retrieved

Recorded conflicts

physical.busbar_terminals Review required
M10 for both 500 A and 1000 A — Lynx Smart BMS manual - Technical specifications
500 A version uses M8, 1000 A version uses M10 — Lithium Battery Smart manual - 3. System design and BMS selection guide

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

BusbarTinned copper, 8 x 30mm
Lynx Distributor linksRJ10, up to 4 modules
Power (OFF mode)0.3mA for all system voltages
Pre-charge minimum load10Ω and above for 12V; 20Ω and above for 24V and 48V
Reverse polarity protectionNo

Build a system with this product