ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseBattery Management Systems

Victron Energy VE.Bus BMS NG

Official manufacturer global verified Sept. 2, 2026

Identity

category battery_management_systems
manufacturer Victron Energy B.V.
model VE.Bus BMS NG
product_family VE.Bus BMS NG
product_status active
region global
sku UNKNOWN

Electrical

charge_disconnect_source_current_limit 10 mA
current_draw_low_cell_voltage 2 mA
current_draw_regular_operation 10 mA
current_draw_remote_off 1,50 mA
input_voltage_range_vdc 9 - 70 VDC
load_disconnect_source_current_limit 1 A
pre_alarm_output 1 A, not short circuit protected
supported_system_voltages_v 12, 24 or 48 V

Physical / mechanical

depth_mm 105.8
dimensions_h_w_d_mm 23,2 x 95,0 x 105,8
height_mm 23.2
weight_g 120
weight_kg 0.12
width_mm 95.0

Installation

max_batteries_12v_24v_systems 50
max_batteries_48v_systems 25
series_parallel 12 V, 24 V or 48 V via series/parallel connection; a maximum of 50 batteries when configuring a bank with 12 V or 24 V batteries, up to 25 batteries with 48 V batteries
supported_battery_types Victron Energy Lithium NG Batteries (12,8 V, 25,6 V and 51,2 V)

Environment

operating_temperature -20 to +50 °C
protection_class_ip IP20

Interfaces & connectors

aux_in Yes
bluetooth UNKNOWN
gx_power_output Yes
remote_panel_port Yes
ve_bus 2 x RJ45 sockets
ve_can UNKNOWN
ve_direct UNKNOWN

Protection

charge_disconnect Charge disconnect output, source current limit 10 mA
load_disconnect Load disconnect output, source current limit 1 A
pre_alarm Pre-alarm output 1 A, not short circuit protected

Certifications

standards ['EN 60950', 'EN 61000-6-3', 'EN 55014-1', 'EN 61000-6-2', 'EN 61000-6-1', 'EN 55014-2', 'EN 50498']

Warranty & service

summary UNKNOWN

Documents

datasheet VE.Bus BMS NG
datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} VE.Bus BMS NG product page — located, not retrieved

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Automotive standardEN 50498
Ports2 x RJ45 sockets; Remote panel port; Aux-in; GX-Power output
documented_relationship:bms_battery{"to_manufacturer": "Victron Energy", "to_model": "Lithium NG battery range (12,8 V / 25,6 V / 51,2 V)", "relationship_type": "bms_battery", "source": "Datasheet - VE.Bus BMS NG", "source_url": "https://www.victronenergy.com/upload/documents/Datasheet-VE-Bus-BMS-NG-EN.pdf", "confidence": "officially-verified", "notes": "Battery compatibility: 'Victron Energy Lithium NG Batteries' in 12.8V, 25.6V and 51.2V configurations"}
documented_relationship:inverter_bms{"to_manufacturer": "Victron Energy", "to_model": "MultiPlus / Quattro inverter-chargers", "relationship_type": "inverter_bms", "source": "Datasheet - VE.Bus BMS NG", "source_url": "https://www.victronenergy.com/upload/documents/Datasheet-VE-Bus-BMS-NG-EN.pdf", "confidence": "officially-verified", "notes": "Provides 2 x RJ45 VE.Bus sockets for inverter/charger control; the VE.Bus BMS family is documented as controlling MultiPlus/Quattro via VE.Bus"}