⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Communication Modules

Victron Energy VE.Direct to RS232 interface

Official manufacturer GLOBAL verified Sept. 23, 2026

Identity

category communication_modules
manufacturer Victron Energy
model VE.Direct to RS232 interface
product_status active
region GLOBAL
variant —

Electrical

manufacturer_part_number ASS030520500
official_product_url https://www.victronenergy.com/accessories/ve-direct-to-rs232-interface
VE.Direct to RS232 interface — inventory record source_url
supply_voltage 100-240 V AC
supported_inverter_families products with a VE.Direct connection
VE.Direct to RS232 interface

Physical / mechanical

mounting DIN-rail

Interfaces & connectors

bluetooth True
can True
cellular True
documented_ports [{'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'VE.Direct', 'port_type': 'VE.Direct', 'direction': 'bidirectional', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'product page', 'quote': 'Connect products with a VE.Direct connection and an RS232 connection'}, {'port_role': 'RS232', 'port_label_from_manual': 'RS232', 'port_type': 'RS232', 'direction': 'bidirectional', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'product page', 'quote': 'Connect products with a VE.Direct connection and an RS232 connection'}]
ethernet True
external_interface RS232 disputed
VE.Direct to RS232 interface
host_interface VE.Direct disputed
VE.Direct to RS232 interface
interfaces RS485, Ethernet, Wi-Fi
rs232 True
VE.Direct to RS232 interface
rs485 True
supported_devices_max 32
wi_fi True

Documents

certificate Certificate Safety IEC 60335-1 - 19 interfaces
certificate Declaration of Conformity - Interfaces
product_page VE.Direct to RS232 interface

Recorded conflicts

interfaces.external_interface Review required
RS232 — stored value
VE.Direct — Connect products with a VE.Direct connection and an RS232 connection with Victron's VE.Direct to RS232 interface.
Detected during import deep-enrich-2026-09-batch08
interfaces.host_interface Review required
VE.Direct — stored value
RS232 — Connect products with a VE.Direct connection and an RS232 connection with Victron's VE.Direct to RS232 interface.
Detected during import deep-enrich-2026-09-batch08

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

builder_completenesspartial
region_notesOne worldwide Victron product page.
withheld:bluetoothfalse
withheld:canfalse
withheld:cellular_4gfalse
withheld:cloud_requiredfalse
withheld:ethernetfalse
withheld:local_accesstrue
withheld:rs485false
withheld:usbfalse
withheld:wififalse