⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Current Transformers (CT)

DENT Instruments CT-HSC-020-U

Official manufacturer GLOBAL verified Sept. 23, 2026

Identity

category current_transformers
manufacturer DENT Instruments
model CT-HSC-020-U
product_status active
region GLOBAL
variant —

Electrical

accuracy_class No IEC class printed; ratio error <0.5% from 0.25 to 40A AC (typical)
20A Mini Hinged CT Data Sheet
aperture_in 0.4
20A Mini Hinged CT Data Sheet
aperture_mm 10
20A Mini Hinged CT Data Sheet
bidirectional True
cable_length_m 3
20A Mini Hinged CT Data Sheet
ct_type split_core disputed
20A Mini Hinged CT Data Sheet
dielectric_strength 3520 VAC for 1 minute
20A Mini Hinged CT Data Sheet
dielectric_withstand_v 3520
20A Mini Hinged CT Data Sheet
flammability_rating UL 94 V-0
20A Mini Hinged CT Data Sheet
frequency_hz 50-400 disputed
20A Mini Hinged CT Data Sheet
housing_material White Nylon, UL 94 V-0
20A Mini Hinged CT Data Sheet
lead_description 600V, 20 gage
20A Mini Hinged CT Data Sheet
max_current_a 100.0
measurement_category CAT III disputed
20A Mini Hinged CT Data Sheet
measurement_type Current Transformer (CT)
measuring_range 0.25 to 40A AC
20A Mini Hinged CT Data Sheet
output_mv_per_a 16.65
20A Mini Hinged CT Data Sheet
phase_count 1
phase_error_deg <1.5° from 1 to 40A AC
20A Mini Hinged CT Data Sheet
phase_shift <1.5° from 1 to 40A AC
20A Mini Hinged CT Data Sheet
phase_shift_low_current <2° From 0.25 to 1A AC
20A Mini Hinged CT Data Sheet
primary_current_a 20
20A Mini Hinged CT Data Sheet
rated_insulation_voltage_v 600
20A Mini Hinged CT Data Sheet
ratio 20 A : 333 mV
20A Mini Hinged CT Data Sheet
ratio_error <0.5% from 0.25 to 40A AC (typical)
20A Mini Hinged CT Data Sheet
secondary_voltage_mv 333
20A Mini Hinged CT Data Sheet
voltage_rating_v 230.0
window_size 0.4" (10 mm)
20A Mini Hinged CT Data Sheet

Environment

operating_temperature_max_c 60
20A Mini Hinged CT Data Sheet
operating_temperature_min_c -15
20A Mini Hinged CT Data Sheet

Certifications

standards UL STD 61010-1, EN 60044-1, CAN/CSA STD C22.2 No. 61010-1 disputed
20A Mini Hinged CT Data Sheet

Documents

datasheet 20A Mini Hinged CT Data Sheet
datasheet AVAILABLE CURRENT TRANSFORMERS (DENT CT overview data sheet)

Recorded conflicts

certifications.standards Review required
UL STD 61010-1, EN 60044-1, CAN/CSA STD C22.2 No. 61010-1 — stored value
['UL STD 61010-1', 'CAN/CSA STD C22.2 No. 61010-1'] — Conforms to: UL STD 61010-1; Certified to: CAN/CSA STD C22.2 No. 61010-1
Detected during import deep-enrich-2026-09-batch09
electrical.measurement_category Review required
CAT III — stored value
Category III — 600 VAC, Category III
Detected during import deep-enrich-2026-09-batch09
electrical.frequency_hz Review required
50-400 — stored value
50 to 400 Hz — 50 to 400 Hz
Detected during import deep-enrich-2026-09-batch09
electrical.ct_type Review required
split_core — stored value
Mini Hinged CT — CT-HSC-020-U Mini Hinged CT
Detected during import deep-enrich-2026-09-batch09

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

builder_completenesscomplete
region_notesOne specification; the datasheet cites UL, CAN/CSA and EN conformity together and prints no market variant.