Identity

category current_transformers
manufacturer Schneider Electric
model METSECT5HG010
product_status active
region GLOBAL

Electrical

accuracy_class 3
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
bidirectional True
conductor_size_mm cable diameter 32.5
PowerLogic Split Core Current Transformer - Type HG, for cable diameter 32.5mm, 0100A / 5A
ct_type split_core
PowerLogic Split Core Current Transformer - Type HG, for cable diameter 32.5mm, 0100A / 5A
dielectric_test_voltage 3 kV, 50 Hz, one minute
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
frequency_hz 50/60 (47-63)
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
installation_category III
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
insulation_class E
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
max_current_a 65.0
measurement_type Current Transformer (CT)
phase_count 1
pollution_degree 2
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
primary_current_a 100
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
rated_burden_va 1.5
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
rated_insulation_voltage_v 720
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
ratio 100/5 A
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
secondary_current_a 5
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
short_time_thermal_current 60 × Ip (max 60 kA) for 1 second
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
voltage_rating_v 230.0

Physical / mechanical

mounting DIN-rail

Environment

ip_rating IP20
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
operating_temperature_max_c 50
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
operating_temperature_min_c -5
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01

Interfaces & connectors

communication RS485 Modbus RTU

Certifications

standards ['IEC 61869-1', 'IEC 61869-2', 'VDE 0414']
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01

Documents

installation_manual Instruction sheet 7EN02-0479-01.pdf
manual PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
product_page METSECT5HG010 product page (IEC open-core current transformer, ratio 100A/5A, 1.5VA, class 3, cable)
product_page PowerLogic Split Core Current Transformer - Type HG, for cable diameter 32.5mm, 0100A / 5A