Identity

category current_transformers
manufacturer Schneider Electric
model METSECT5HJ060
product_status active
region GLOBAL
variant —

Electrical

accuracy_class 0.5
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
aperture_mm 42.4 (ø)
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
bidirectional True
burden_va 2.5
conductor_size_mm cable diameter 42.4
PowerLogic Split Core Current Transformer - Type HJ, for cable diameter 42.4mm, 0600A / 5A
ct_internal_type HJ
ct_type split_core
PowerLogic Split Core Current Transformer - Type HJ, for cable diameter 42.4mm, 0600A / 5A
dielectric_strength 3 kV, 50 Hz for one minute
dielectric_test_voltage 3 kV, 50 Hz, one minute
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
frequency_hz 50/60 (47-63) disputed
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
installation_category III
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
insulation_class E
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
insulation_voltage_v 720
max_current_a 65.0
measurement_type Current Transformer (CT)
phase_count 1
pollution_degree 2
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
primary_current_a 600
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
rated_burden_va 2.5
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
rated_insulation_voltage_v 720
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
ratio 600/5 A
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
secondary_current_a 5
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
secondary_output 5 A
short_time_thermal_current 60 × Ip (max 60 kA) for 1 second
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
voltage_rating_v 230.0
window_dimensions_mm 42.4 x 85 (internal profile)

Physical / mechanical

mounting DIN-rail

Environment

ip_rating IP20
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
operating_temperature_max_c 50
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
operating_temperature_min_c -5
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
operating_temperature_range_c -5 to +50

Interfaces & connectors

communication RS485 Modbus RTU

Protection

protection_degree_ip IP20

Certifications

certifications IEC 61869-1, IEC 61869-2, VDE 0414
standards ['IEC 61869-1', 'IEC 61869-2', 'VDE 0414']
PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01

Documents

datasheet Schneider Electric Current transformer T1 METSECT5HJ060 product datasheet
installation_manual Instruction sheet 7EN02-0479-01.pdf
manual PowerLogic Split Core Current Transformers Type G / Type H - Instruction sheet 7EN02-0479-01
product_page METSECT5HJ060 product page (Split-core IEC current transformer, 600 A primary / 5 A secondary, 42.4 mm cable diameter)
product_page PowerLogic Split Core Current Transformer - Type HJ, for cable diameter 42.4mm, 0600A / 5A

Recorded conflicts

electrical.frequency_hz Review required
50/60 (47-63) — stored value
50 / 60 (range 47-63) — incoming package
Detected during import deep-enrich-pass2-2026-09-batch15

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

builder_completenesscomplete
region_notesIEC reference sold worldwide; opened on se.com Singapore, which serves the same IEC reference as the global (ww) catalogue.