Seeed Studio SenseCAP S2100
Manufacturer documented GLOBAL
Identity
| category | data_loggers |
| manufacturer | Seeed Studio |
| model | SenseCAP S2100 |
| mpn | 114992872 |
| product_family | SenseCAP S210x |
| region | GLOBAL |
| series | SenseCAP |
Electrical
| battery_backup |
True
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 22
|
| battery_capacity_ah |
19 Ah
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 66
|
| battery_life_years |
10 years
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 65
|
| battery_rechargeable |
False
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 66
|
| battery_type |
Standard D-size SOCl2 Battery
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 67
|
| bluetooth |
True
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 50
|
| current_input_count |
2
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 39
|
| current_input_range |
4 to 20 mA mA
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 39
|
| current_input_resolution |
0.001 mA mA
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/tutorial/How_to_Configure_the_Analog_Sensor_for_S2100_Data_Logger.md — line 69
|
| dc_power_supply_v |
12 V
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 77
|
| digital_input_count |
1
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 87
|
| digital_input_modes |
level or pulse
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 87
|
| frequency_plan_count |
7
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/tutorial/How_to_Configure_the_Analog_Sensor_for_S2100_Data_Logger.md — line 140
|
| lora_frequency_range |
863MHz ~928MHz MHz
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 28
|
| lorawan_class |
Class A
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 49
|
| lorawan_frequency_plans |
IN865/EU868/US915/AU915/ AS923
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 51
|
| lorawan_version |
v1.0.3
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 49
|
| max_tx_power_dbm |
19 dBm
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 52
|
| microcontroller |
Wio-E5
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 48
|
| ota_update |
True
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 22
|
| remote_management |
SenseCAP Mate APP and SenseCAP Portal
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 31
|
| rx_sensitivity |
-136dBm@SF12 BW=125KHz
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 53
|
| sensor_supply_voltage_options |
3V/5V/12V V
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/tutorial/How_to_Configure_the_Counter&GPIO_Sensor_for_S2100_Data_Logger.md — line 234
|
| voltage_input_count |
2
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 40
|
| voltage_input_range |
0 to 10V V
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 40
|
| voltage_input_resolution |
0.01 mV mV
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/tutorial/How_to_Configure_the_Analog_Sensor_for_S2100_Data_Logger.md — line 71
|
Physical / mechanical
| weight_g |
280 g
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 58
|
Environment
| ip_rating |
IP66
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 55
|
| operating_temperature_max_c |
85 °C
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 56
|
| operating_temperature_min_c |
-40 °C
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 56
|
| relative_humidity |
0 to 100 %RH (non-condensing)
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 57
|
Interfaces & connectors
| communication_distance_line_of_sight_km |
10 km
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 29
|
| communication_distance_urban_km |
2 km
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 29
|
| concurrent_interface_mode |
single-channel collector
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 83
|
| device_type | Battery/12V powered IP66 LoRaWAN data logger for RS485 Modbus-RTU, analog (4-20mA/0-10V) and GPIO sensors |
| modbus_rtu |
True
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 41
|
| rs485 |
True
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 41
|
| rs485_max_measurements |
10
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/tutorial/How_to_Configure_the_12V_RS485_Sensor_for_S2100_Data_Logger.md — line 219
|
Certifications
| certifications |
CE / FCC / RoHS
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/Data_Logger.md — line 59
|
Documents
product-page
SenseCAP S2100 LoRaWAN Data Logger (Seeed shop)
technical-manual
SenseCAP S2100 LoRaWAN Data Logger wiki
technical-manual
SenseCAP S2100 — sites/en/docs/Sensor/SenseCAP/SenseCAP_Data_Logger/tutorial/How_to_Configure_the_12V_RS485_Sensor_for_S2100_Data_Logger.md