Solis (Ginlong Technologies Co., Ltd.) S3-Logger
Official manufacturer GLOBAL verified Sept. 25, 2026
Identity
| category | data_loggers |
| manufacturer | Solis (Ginlong Technologies Co., Ltd.) |
| model | S3-Logger |
| product_status | active |
| region | GLOBAL |
| variant | — |
Electrical
| ethernet_port_count |
1
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| ethernet_spec |
LAN × 1, 10 / 100 Mbps adaptive, communication distance ≤ 100 m
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| export_control |
True
S3-Logger
|
| local_monitoring_supported |
True
S3-Logger
|
| max_connected_devices |
60
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| max_connected_inverters |
30
S3-Logger
|
| max_devices_per_rs485_port |
15
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| max_operating_altitude_m |
4000
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| official_product_url |
https://www.solisinverters.com/global/accessories12/S3-Logger_gl.html
S3-Logger — inventory record source_url
|
| power_consumption_w |
5
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| power_supply_ac |
100 ~ 240 V, 50 Hz / 60 Hz
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| power_supply_dc |
9 ~ 36 V
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| relative_humidity |
≤ 85%, Non-condensing
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| rs485_baud_rate |
1200 ~ 115200 bps
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| rs485_communication_distance_m |
1000
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| rs485_port_count |
4
S3-Logger
|
| supply_voltage | 100-240 V AC |
| supported_device_types |
['Solis inverters', 'Solis meters', 'third-party irradiance sensors', 'wind sensors', 'weather stations']
disputed
S3-Logger
|
Physical / mechanical
| dimensions_mm |
89 × 121 × 27
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| mounting | DIN-rail |
Environment
| ip_rating |
IP20
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| operating_temperature_max_c |
80
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| operating_temperature_min_c |
-40
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| storage_temperature_max_c |
80
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| storage_temperature_min_c |
-40
Solis S3-Logger Flyer / Datasheet AU V2.4
|
Interfaces & connectors
| documented_ports | [{'port_role': 'RS485', 'port_label_from_manual': 'RS485 COM', 'port_type': 'RS485', 'direction': 'BIDIRECTIONAL', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Communication', 'quote': 'RS485 COM 4, 1200 ~ 115200 bps, communication distance ≤ 1000 m'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'LAN', 'port_type': 'ETHERNET', 'direction': 'BIDIRECTIONAL', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Communication', 'quote': 'Ethernet communication LAN × 1, 10 / 100 Mbps adaptive, communication distance ≤ 100 m'}] |
| interfaces | RS485, Ethernet, Wi-Fi |
| protocols |
['Modbus-RTU', 'IEC60870-5-103', 'DLT645', 'Modbus-TCP', 'IEC60870-5-104']
Solis S3-Logger Flyer / Datasheet AU V2.4
|
| supported_devices_max | 32 |
Certifications
| certifications |
['CE', 'RoHS']
Solis S3-Logger Flyer / Datasheet AU V2.4
|
Documents
datasheet
S3-Logger AU Flyer V2.4
product_page
S3-Logger
product_page
Solis S3-Logger product page (Solis Australasia)
user_manual
S3-Logger User Manual
user_manual
Solis S3-Logger User Manual
Recorded conflicts
electrical.supported_device_types Review required
['Solis inverters', 'Solis meters', 'third-party irradiance sensors', 'wind sensors', 'weather stations'] — stored value
Solis inverter — Supported device type Solis inverter
Detected during import deep-enrich-2026-09-batch11
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| builder_completeness | partial |