Official manufacturerGlobal (12/24/48V DC systems)verified Sept. 2, 2026
PRODUCT PHOTO
Identity
category
dc_distribution
manufacturer
Victron Energy B.V.
model
Lynx Distributor
product_family
Lynx Distribution System
product_status
active
product_status_evidence
Listed as a current product in the DC distribution systems category on victronenergy.com.
region
Global (12/24/48V DC systems)
sku
UNKNOWN
sku_note
No article/order code appears in the fetched manual or product page text. Sold in M8 and M10 busbar versions.
variants
M8 and M10 busbar versions; the manual publishes a single shared specification table for both.
Electrical
continuous_current_rating
1000Adc continuous
current_rating_statement
'The Lynx Distributor, Lynx Shunt VE.Can, Lynx Class-T Power In and the Lynx Power In are rated for a nominal current of 1000A for 12, 24 or 48 System voltages.'
reverse_polarity_protection
Yes (excluding RJ10 connections)
self_consumption
Maximum 100mA (with all LEDs illuminated)
supported_system_voltages
12, 24 or 48V
voltage_range
9 - 60Vdc
Physical / mechanical
busbar_dimensions_hxw
8 x 30mm
busbar_material
Tinned copper
dimensions_hxwxd
290 x 170 x 80 mm
enclosure_material
ABS
protection_class
IP22
weight
2.2 kg
Installation
bolt_torque
UNKNOWN
busbar_connection
M8 or M10 (version dependent)
fuse_connection
M8
fuse_type
MEGA fuses - 'These spaces have been designed to fit MEGA fuses.' Use 36V-rated MEGA fuses for 12V and 24V systems and 58V-rated MEGA fuses for 48V systems.
fuses_included
UNKNOWN
maximum_total_fuse_rating
'The total value of the fuses of all circuits should not be more than the current rating of the Lynx module or the Lynx model with the lowest current rating in case of multiple Lynx modules are used.'
number_of_dc_circuits
4
number_of_fuse_positions
Four - the Lynx Distributor contains spaces for four fuses, one per DC circuit
Environment
humidity
Max. 95% (non-condensing)
operating_temperature_range
-40°C to +60°C
storage_temperature_range
-40°C to +60°C
Interfaces & connectors
bluetooth
Not present on this module
fuse_monitoring
Per-fuse LED. 'When a fuse blows, the red fuse LED will illuminate, the power LED will turn red, and an alarm message is sent to a connected Lynx Smart BMS.'
rj10
40 cm RJ10 cable (included). 'The RJ10 cable supplies power to the Lynx Distributor from a Lynx Smart BMS or Lynx Shunt VE.Can and transfers data between the Lynx Distributor and the Lynx Smart BMS.' For standalone operation pin 1 connects to 5V (4.5V-5.5V) and pin 4 to GND.
ve_can
Not present on this module
Protection
fuse_blown_indication
Red fuse LED plus red power LED plus alarm message to a connected Lynx Smart BMS
reverse_polarity_protection
Yes (excluding RJ10 connections)
Certifications
standards
['UNKNOWN - a Declaration of Conformity PDF covering Lynx DC distribution is published but was not fetched, so no standard is claimed']
Warranty & service
summary
5-year standard warranty with global repair service
Documents
certificate
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Declaration of Conformity - Lynx DC distribution (2023-08-28) — located, not retrieved
drawing
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Distributor enclosure dimensions (M10) — located, not retrieved
drawing
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Distributor enclosure dimensions (M8) — located, not retrieved
manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}