go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
Official manufacturer EU (Austria) verified Sept. 2, 2026
go-e Charger Gemini product page, image 'go-e-charger-gemini-11-kw-mit-kabel'
go-e Charger Gemini product page, image 'go-e-charger-gemini-seitenansicht' (side view)
Identity
| cable_or_socket | Type 2 socket (EN 62196-2) with mechanical locking device; fixed 1.8 m supply cable |
| category | ev_chargers |
| ean | UNKNOWN |
| manufacturer | go-e GmbH |
| market_version | EU. Manual/datasheet: 'The go-e Charger Gemini must not be used in the following countries: Sweden, Denmark, Netherlands, France, Italy and United Kingdom.' |
| model | go-eCharger Gemini (11kW and 22kW variants) |
| mpn | UNKNOWN |
| product_family | go-e Charger Gemini / Gemini 2.0 |
| product_status | active |
| region | EU (Austria) |
| sku | UNKNOWN |
| variants | 11 kW (16 A, 3-phase) and 22 kW (32 A, 3-phase) |
Electrical
| adjustable_current_range_a | 6-16A or 6-32A depending on variant, 1A increments |
| api_cloud | True |
| api_local | True |
| dynamic_load_balancing | True |
| home_assistant_integration | via-integration (HACS 'goecharger-api2', local HTTP/WebSocket API v2) |
| max_current_a | 16 (11kW) / 32 (22kW) |
| max_power_kw | 11 / 22 |
| meter_integration | Built-in energy meter; open local API/Modbus TCP/MQTT for external meter/PV data. Specific certified third-party meter brand list not itemized. |
| modbus_support | True |
| mqtt_support | True |
| ocpp_support | OCPP 1.6 (requires WiFi) |
| phase_type | single-phase or three-phase |
| solar_surplus_charging | True |
| supported_inverter_ems_integrations | Broad third-party/open-source EMS support via open local API (used by evcc, openWB, ioBroker); no named inverter-brand certifications in the datasheet |
Physical / mechanical
| cable_length_m | 1.8 |
| depth_mm | 110 |
| enclosure_material | high-performance plastic |
| height_mm | 260 |
| housing_color | UNKNOWN |
| mounting_bolt_size |
5x dowel 8 x 40 mm, 4x wall-bracket screws 4.5 x 50 mm
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — manual p.17: '5x Dowel 8 x 40 mm, 4x Screws for wall bracket 4.5 x 50 mm'
|
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_type | ['wall'] |
| shipping_weight_kg | UNKNOWN |
| supply_cable_spec | 11 kW: 1.8 m, 5 x 2.5 mm2 (type H07BQ-F); 22 kW: 1.8 m, 5 x 6 mm2 (type H07BQ-F) |
| torque_specs | UNKNOWN |
| weight_kg | 1.85 (11 kW) / 2.34 (22 kW) |
| width_mm | 155 |
Installation
| direct_sunlight_restriction | must not be installed in direct sunlight |
| grid_types | TT / TN / IT (deactivatable ground check for IT grid - Norway mode) |
| indoor_outdoor | Indoors and outdoors, without direct sunlight |
| max_installation_altitude_m | 2000 |
| mounting_height_mm |
approx. 1000 to 1450 mm above the ground
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — manual p.17: 'approx. 1.00 to 1.45 meters above the ground'
|
| mounting_orientation | 'The go-e Charger must be mounted vertically in the wall bracket on a flat wall' |
| orientation_allowed | ['vertical'] |
| required_rcd_type | separate upstream residual current circuit breaker at least type A (I-dn = 30 mA AC) |
| required_upstream_breaker |
'Miniature circuit breakers with characteristic B or C for 16 or 32 amperes are permissible: 3- or 4-pole for three-phase connection, 2-pole for single-phase connection'
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — manual p.19
|
Environment
| cooling_method | UNKNOWN |
| ik_rating |
IK08
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — manual p.12-13: 'IK08'
|
| ip_rating |
IP65 (official installation and operating manual)
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — installation and operating manual p.12-13 technical data: 'IP65'
|
| max_altitude_m | 2000 |
| operating_temperature_c | -25 to +40 |
| pollution_degree | II |
| relative_humidity | not more than 95 % (non-condensing) |
| storage_temperature_c | -40 to +85 |
Interfaces & connectors
| bluetooth | UNKNOWN |
| cellular | 4G LTE / 2G EDGE (Gemini 2.0 only) |
| cloud_api | HTTP Cloud API |
| connector_type | Type 2 socket (EN 62196-2) with mechanical locking device |
| ethernet | not fitted |
| load_balancing |
static load balancing: yes; dynamic load balancing with go-e Controller: yes
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — manual p.14-15 smart features table
|
| local_api | local HTTP API over WiFi/hotspot |
| meter_inputs | integrated electricity meter (total kWh and total per RFID chip); external measurement via go-e Controller |
| modbus_rtu | UNKNOWN |
| modbus_tcp | yes (WiFi only) |
| mqtt | MQTT API (WiFi only) |
| ocpp | OCPP 1.6 (marked in the manual as a Gemini 2.0 feature; the Gemini datasheet lists OCPP 1.6 without that restriction - see data_conflicts) |
| protocol_notes | PV surplus charging requires the go-e Controller (internet connection required for the Controller). go-e states 'The go-e Controller is compatible with all kinds of PV inverters and AC electricity storage solutions' and that 'Direct measurement of inverter production is not required for PV optimisation'; 'DC battery systems can't be measured'. Third-party PV-surplus routes named by go-e: Clever-PV and Solar Manager; 'some integrations do not use our API but OCPP for PV surplus'. |
| rfid | 13.56 MHz; management of RFID chips/cards, up to 10 users per charger |
| rs485 | UNKNOWN |
| wifi | 802.11 b/g/n 2.4 GHz, frequency band 2412-2472 MHz |
Controls & display
| buttons | UNKNOWN |
| display_type | none (LED ring) |
| leds | LED ring, brightness adjustable (standby 3.1 W LEDs dark to 5.2 W LEDs bright) |
| local_display | False |
| mobile_app | go-eCharger app (local via WiFi hotspot or worldwide via WiFi) |
| web_interface | local web interface over the charger hotspot |
Protection
| anti_theft | charging cable locking device |
| dc_leakage_detection | 6 mA DC |
| ground_fault_protection | ground check for TT and TN grids (deactivatable for IT grid - Norway mode) |
| over_temperature | temperature sensors regulate the charging current in case of overtemperature |
| over_voltage | phase and voltage testing |
| overvoltage_category | UNKNOWN |
| protection_class | I |
| residual_current_monitoring |
RCD protection module with DC current detection, I-dn = 20 mA AC and 6 mA DC
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — manual p.13/p.19: 'IDn = 20mA AC and 6 mA DC'
|
| under_voltage | phase and voltage testing |
| welded_relay_detection | UNKNOWN |
Certifications
| emc | [] |
| grid_codes | [] |
| other | [] |
| regional | ['CE (Directive 2014/53/EU)'] |
| safety | ['EN IEC 61851-1:2019', 'EN 62196-2 (Type 2 socket)'] |
Warranty & service
| conditions | '36 months (deviating from this in UK 60 months) from receipt of the goods after the first purchase'. Covers material and functional defects; excludes improper use, installation errors, modifications, or device opening. |
| design_life_years | UNKNOWN |
| extended_options_years | UNKNOWN |
| standard_years |
3
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual — manual p.36
|
Documents
compatibility-list
Integrations (go-e partner list)
installation-manual
go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual
press-release
go-e steps up cooperation with Fronius (press release)
product-page
PV Surplus Charging (go-e solutions page)
product-page
go-eCharger product page
Recorded conflicts
interfaces.ocpp Review required
OCPP 1.6 available on go-e Charger Gemini — go-e Charger Gemini Datasheet (distributor CDN), fetched 2026-09-02
OCPP 1.6 marked with an asterisk meaning 'Gemini 2.0 only' — go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual p.12-15, fetched 2026-09-02
the combined Gemini / Gemini 2.0 manual flags OCPP and cellular connectivity as Gemini 2.0 features; the older single-product datasheet does not distinguish. Needs confirmation of which hardware generation the DB record covers.
environment.ip_rating Review required
IP55 — go-e Charger Gemini Datasheet hosted on distributor CDN cdn.bitelec.ch, fetched 2026-09-02
IP65 — go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual, go-e.com/fileadmin, p.12-13, fetched 2026-09-02; also 'IP65' on the go-e product page
the distributor-hosted datasheet is an older revision (V 1.0 / V 2.0 DE); go-e's own manual and current product page both state IP65. Stored value = IP65 (better-sourced).
interfaces.ocpp Review required
OCPP 1.6 available on go-e Charger Gemini — go-e Charger Gemini Datasheet (distributor CDN), fetched 2026-09-02
OCPP 1.6 marked with an asterisk meaning 'Gemini 2.0 only' — go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual p.12-15, fetched 2026-09-02
the combined Gemini / Gemini 2.0 manual flags OCPP and cellular connectivity as Gemini 2.0 features; the older single-product datasheet does not distinguish. Needs confirmation of which hardware generation the DB record covers.
environment.ip_rating Review required
IP55 — go-e Charger Gemini Datasheet hosted on distributor CDN cdn.bitelec.ch, fetched 2026-09-02
IP65 — go-e Charger Gemini & Gemini 2.0 Installation and Operating Manual, go-e.com/fileadmin, p.12-13, fetched 2026-09-02; also 'IP65' on the go-e product page
the distributor-hosted datasheet is an older revision (V 1.0 / V 2.0 DE); go-e's own manual and current product page both state IP65. Stored value = IP65 (better-sourced).
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Adjustable current step size | 6-16 A (11 kW) or 6-32 A (22 kW) in 1 A steps |
| Charging modes | kWh limit mode / ECO mode / Planned charge mode |
| Dynamic energy tariffs | Dynamic energy tariffs yes; Flexible energy tariffs with intelligent charging management (Gemini 2.0) |
| Geographic restriction | The go-e Charger Gemini must not be used in the following countries: Sweden, Denmark, Netherlands, France, Italy and United Kingdom. |
| Officially listed integration partners (PV/EMS) | clever-PV, Perific, Jedlix, gridX, Nexxtlab, Last Mile Solutions, TAP Electric, Enode, Eniris, Reduxi, Ostrom, Embion, EcoFlow, Scopt, Habitaio, Hedengren, Enphase Energy, TEKKO, Consolinno, Kiwigrid, neoom, Loxone, Monta, E-Flux, eCarUp, Sparklin, EVesto, eParking, vaylens, chargecloud |
| PV surplus third-party routes | Clever-PV and Solar Manager; 'some integrations do not use our API but OCPP for PV surplus' |
| RFID user management | Management of RFID chips/cards (up to 10 users per charger) |