Knowledge Base ›
EV Chargers
Sungrow AC011E-01
Official manufacturer
GLOBAL
verified Sept. 3, 2026
Identity
| category |
ev_chargers
|
| device_type |
AC EV charger (wallbox), tethered
|
| generation |
E-01
|
| manufacturer |
Sungrow
|
| model |
AC011E-01
|
| product_family |
Sungrow AC Charger (E-01 series)
|
| product_name |
AC011E-01
|
| region |
GLOBAL
|
| region_variants |
AC011E-01 (advanced version) and AC011E-01 L1 (standard version) are covered by the same user manual
|
| sibling_models |
['AC007E-01', 'AC011E-01 L1']
|
Electrical
| ac_input_voltage |
400 Vac (+/- 20%)
|
| adjustable_current_range |
UNKNOWN
|
| earthing_system |
UNKNOWN
|
| grid_connection |
3-phase
|
| max_charging_current_a |
16
|
| max_input_current_a |
16
|
| nominal_frequency |
50/60 Hz
|
| rated_power_kw |
11
|
| standby_consumption |
< 5 W
|
Physical / mechanical
| ac_cable_specification |
2.5 mm^2 x 5
|
| cable_variant |
tethered cable
|
| charging_cable_length_m |
7
|
| connector_type |
AC Type 2
|
| dimensions_w_h_d_mm |
205 x 310 x 92
|
| weight_kg |
3.8
|
Installation
| commissioning_app |
iSolarCloud (AC011E-01)
|
| max_units_networked |
UNKNOWN
|
| meter_requirement |
DTSU666 Smart Energy Meter (optional) required for dynamic load management
|
| mounting |
Wall-mounting (default); Stand column (optional)
|
Environment
| cooling |
UNKNOWN
|
| humidity |
5-95 % non-condensing
|
| max_altitude_m |
2000
|
| operating_temperature_c |
-30 to 50
|
Interfaces & connectors
| authentication |
RFID card; app
|
| bluetooth |
UNKNOWN
|
| cellular_4g |
UNKNOWN
|
| charging_modes |
Eco charging / Fast charging / Scheduled charging / Customized charging
|
| communication |
WLAN (ESP32 module); RS485 (to Sungrow inverter)
|
| dynamic_load_balancing |
ALM (adaptive load management)
|
| ethernet |
UNKNOWN
|
| isolarcloud_integration |
iSolarCloud app
|
| ocpp_version |
OCPP 1.6 J
|
| pv_surplus_charging |
UNKNOWN
|
| rfid |
Mifare ISO 14443 A (two RFID cards included)
|
Protection
| charging_standard |
UNKNOWN
|
| external_rcd_requirement |
Type A RCD, 30 mA, 25 A / 400 V, externally installed
|
| ik_rating |
IK08
|
| integrated_protections |
Integrated DC residual current detection 6 mA; overload; over-temperature; leakage current detection; surge protection AC Type II; ground fault
|
| ip_rating |
IP65
|
Certifications
| marks |
UNKNOWN
|
| standards |
EN 300 328, EN 300 330, EN 301 489-1/3/17, EN IEC 61000-6-1/3, EN IEC 61851-1/21, EN IEC 62311
|
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| manufacturer_legal_entity_as_printed | Sungrow Power Supply Co., Ltd. |