Knowledge Base ›
EV Chargers
Sungrow IDC30E
Official manufacturer
GLOBAL
verified Sept. 3, 2026
Identity
| category |
ev_chargers
|
| device_type |
DC fast EV charger, 30 kW
|
| manufacturer |
Sungrow
|
| model |
IDC30E
|
| product_family |
Sungrow DC Charger (isolated air-cooling)
|
| product_name |
IDC30E
|
| region |
GLOBAL
|
| region_variants |
An AU-specific datasheet (DS_20240722_IDC30E_AU_Datasheet_V3_EN) exists but was not fetched, so AU values are not recorded
|
Electrical
| dc_output_voltage_range |
200 Vdc - 1000 Vdc
|
| earthing_system |
TN-C, TN-S, TN-C-S, TT
|
| frequency_range |
45 Hz - 65 Hz
|
| grid_connection |
3 / N / PE, 380 Vac / 400 Vac (+/- 10 %)
|
| max_efficiency |
96.5 %
|
| max_input_current_a |
52
|
| max_output_current_a |
80
|
| nominal_frequency |
50 Hz / 60 Hz
|
| power_factor |
>= 0.99
|
| rated_input_current_a |
46
|
| rated_power_kw |
30
|
| thdi |
< 5 % at full output power
|
Physical / mechanical
| cable_variant |
tethered cable
|
| charging_cable_length_m |
5
|
| connector_type |
CCS2
|
| dimensions_w_h_d_mm |
500 x 800 x 288
|
| display |
7-inch colour touch screen
|
| number_of_outputs |
1
|
| weight_kg |
55
|
Installation
| commissioning_app |
iEnergyCharge management platform
|
| meter_requirement |
UNKNOWN
|
| mounting |
Wall-mounting (default); Stand column, trolley (optional)
|
Environment
| anti_corrosion |
C5
|
| cooling |
Smart forced air cooling
|
| humidity |
5 % - 95 % non-condensing
|
| max_altitude_m |
2000
|
| noise |
<= 50 dB(A)
|
| operating_temperature_c |
-35 to 55
|
Interfaces & connectors
| authentication |
RFID-card, Plug & Play, Auto-charge, Plug & Charge, Payment terminal (optional)
|
| communication |
4G, Ethernet, WLAN
|
| isolarcloud_integration |
UNKNOWN
|
| language |
English (default), others by firmware upgrade
|
| ocpp_version |
OCPP 1.6 J, Ready for OCPP 2.0.1
|
| rfid |
ISO / IEC 14443 A / B, ISO / IEC 15693
|
Protection
| external_rcd_requirement |
UNKNOWN
|
| ik_rating |
IK10
|
| integrated_protections |
Over/under voltage; over-current; short-circuit; over-temperature; surge protection; emergency stop (integrated)
|
| ip_rating |
IP65
|
Certifications
| marks |
CE, CB, UKCA, RCM, ADQCC, MoIAT, PEA, SASO, MEW
|
| standards |
UNKNOWN
|
Documents
datasheet
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
IDC30E AU Datasheet V3 EN — located, not retrieved
rev V3
user_manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
IDC30E User Manual — located, not retrieved
rev UNKNOWN
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| manufacturer_legal_entity_as_printed | Sungrow Power Supply Co., Ltd. |
Build a system with this product