Identity

category external_mppt_controllers
ean —
generation —
manufacturer Victron Energy B.V. disputed
market_version —
model BlueSolar MPPT 100/30
mpn SCC020030200
product_family BlueSolar MPPT 100/30 & 100/50
product_status active
region global
release_year —
sku SCC020030200
sku_source 'SCC020030200 BlueSolar MPPT 100/30'

Electrical

battery_voltage_auto_select True
battery_voltage_locator 'Battery voltage: 12/24V Auto Select'
battery_voltage_nominal_v 12/24/36/48V Auto
battery_voltage_options_v [12, 24]
charge_algorithm Multi-stage adaptive (eight pre-programmed algorithms) or user defined algorithm
charge_voltage_absorption_v Default: 14.4 V / 28.8 V (adjustable)
charge_voltage_equalization_v 16.2 V / 28.8 V (adjustable) as printed in the SmartSolar manual; disabled by default
charge_voltage_float_v Default: 13.8 V / 27.6 V (adjustable)
load_output_continuous_current_a none - this model has no load output
max_charge_current_a 30
max_charge_current_locator 'Rated charge current' (datasheet)
max_efficiency_pct 98.0
max_pv_open_circuit_voltage_locator 'Maximum PV open circuit voltage' = 100 V
max_pv_open_circuit_voltage_v 100
max_pv_power_locator 'Nominal PV power, 12 V' / 'Nominal PV power, 24 V'
max_pv_power_w_by_battery_voltage {'12': 440, '24': 880}
max_pv_short_circuit_current_a 35
max_pv_short_circuit_current_locator 'Max. PV short circuit current'
mppt_operating_voltage_max_v —
mppt_operating_voltage_min_note 'PV voltage must exceed battery voltage + 5V to start; minimum thereafter is battery voltage + 1V'
num_trackers —
num_trackers_note Victron does not publish a 'number of MPP trackers' row for this model in any document fetched this session; the unit has a single PV input pair. Recorded as UNKNOWN rather than assumed. (For the 150/60 and larger families the manual does state MC4 connector pairs are internally parallel-connected to a single MPPT tracker.)
official_manual_url https://www.victronenergy.com/upload/documents/Manual_BlueSolar_100-30__100-50/29694-MPPT_solar_charger_manual-pdf-en.pdf
MPPT solar charger manual BlueSolar MPPT 100/30 & 100/50 Rev 12 - 06/2026 — search-index listing (query: Victron BlueSolar MPPT 100/30 100/50 150/35 150/45 manual pdf); document located, not fetched
peak_efficiency_pct 98
self_consumption 12 V: 30 mA / 24 V: 20 mA
temperature_compensation 12 V: -16 mV/degC / 24 V: -32 mV/degC

Physical / mechanical

bracket_dimensions_mm 176 x 186 x 71.5 (overall outline including mounting flanges, dimension drawing)
depth_mm 70
dimensions_locator 'Dimensions (h x w x d) 130 x 186 x 70 mm'
enclosure_material —
height_mm 130
housing_color Blue (RAL 5012)
mounting_hole_diameter_mm 5 (100/30 drawing, corner radius R4)
mounting_hole_spacing_mm 122 x 131 (100/30 drawing) / 132 x 122 (100/50-150/35-150/45 drawing)
mounting_type ['wall']
power_terminals 16 mm2 / AWG6
shipping_weight_kg —
weight_kg 1.3
width_mm 186
wire_cross_section_mm2 16 mm2 / AWG6

Installation

altitude_derating_note UNKNOWN - not published in the BlueSolar datasheet
indoor_outdoor —
max_installation_altitude_m —
mounting_orientation —

Environment

cooling_method —
ip_rating IP43 (electronics), IP22 (connection area)
max_altitude_m —
nema_rating —
operating_temperature_c -30 to +60 (full rated output up to 40)
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0
pollution_degree —
relative_humidity 95%, non-condensing
storage_temperature_c —

Interfaces & connectors

battery_terminal_type screw terminal, 16 mm2 / AWG6
bluetooth No - not built in. Datasheet 'Bluetooth: VE.Direct Bluetooth Smart dongle needed'
communication VE.Direct / Bluetooth
ethernet —
load_output False
pv_connector_type screw terminal, 16 mm2 / AWG6
relay_outputs —
remote_on_off —
rs485 —
ve_can False
ve_direct Yes - 'Data communication port: VE.Direct'
wifi —

Protection

over_temperature Yes
over_voltage —
pv_reverse_polarity UNKNOWN - the SmartSolar manual lists only 'Output short circuit, over temperature' for this family, while the BlueSolar datasheet lists 'PV reverse polarity, output short circuit, over-temperature'
short_circuit Output short circuit
under_voltage —

Certifications

standards ['EN/IEC 62109-1', 'UL 1741', 'CSA C22.2 NO.107.1-16']

Warranty & service

summary —

Documents

datasheet BlueSolar Charge Controllers MPPT 100/30 & 100/50 — datasheet
dimension-drawing Dimension drawing BlueSolar & SmartSolar MPPT 100/30
product-page BlueSolar MPPT 100/30 & 100/50 — official product page
technical-manual MPPT solar charger manual BlueSolar MPPT 100/30 & 100/50 Rev 12 - 06/2026

Recorded conflicts

identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import system-topology-2026-09-batch02

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Charge algorithmMulti-stage adaptive (eight pre-programmed algorithms) or user defined algorithm
ColourBlue (RAL 5012)
Environmental conditionIndoor type 1, unconditioned
Pollution degreeUNKNOWN