ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseExternal MPPT Controllers

Victron Energy BlueSolar MPPT 150/35

Official manufacturer global verified Sept. 2, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category external_mppt_controllers
ean UNKNOWN
generation UNKNOWN
manufacturer Victron Energy B.V.
market_version UNKNOWN
model BlueSolar MPPT 150/35
mpn SCC020035000
product_family BlueSolar MPPT 150/35 & 150/45
product_status active
region global
release_year UNKNOWN
sku SCC020035000
sku_source 'SCC020035000 BlueSolar MPPT 150/35'

Electrical

battery_voltage_auto_select 12 / 24 / 48 V auto select; 36 V manual select
battery_voltage_locator Manual: 'Battery voltage 12V / 24V / 48V Auto select, 36V: Manual select'
battery_voltage_options_v [12, 24, 36, 48]
charge_algorithm Multi-stage adaptive, eight pre-programmed algorithms or user defined
charge_voltage_absorption_v Default: 14,4 / 28,8 / 43,2 / 57,6 V (adjustable)
charge_voltage_equalization_v 16.2 / 32.4 / 48.6 / 64.8 V (adjustable); disabled by default
charge_voltage_float_v Default: 13,8 / 27,6 / 41,4 / 55,2 V (adjustable)
internal_temperature_sensor Yes (datasheet feature list: 'Internal temperature sensor')
load_output_continuous_current_a none - this model has no load output
max_charge_current_a 35
max_charge_current_locator Datasheet 'Rated charge current'; manual 'Maximum battery current'
max_pv_open_circuit_voltage_locator Datasheet: 'Maximum PV open circuit voltage 150 V absolute maximum coldest conditions / 145 V start-up and operating maximum'
max_pv_open_circuit_voltage_v 150
max_pv_power_locator 'Nominal PV power, 12 V / 24 V / 36 V / 48 V'
max_pv_power_w_by_battery_voltage {'12': 500, '24': 1000, '36': 1500, '48': 2000}
max_pv_short_circuit_current_a 40
mppt_operating_voltage_max_locator Datasheet 'Maximum PV open circuit voltage ... 145 V start-up and operating maximum' (the manual prints only 150 V - see data_conflicts)
mppt_operating_voltage_max_v 145
mppt_operating_voltage_min_note 'PV voltage must exceed battery voltage plus 5V to initiate operation; minimum sustained PV voltage is battery voltage plus 1V'
num_trackers UNKNOWN
num_trackers_note Victron does not publish a 'number of MPP trackers' row for this model in any document fetched this session; the unit has a single PV input pair. Recorded as UNKNOWN rather than assumed. (For the 150/60 and larger families the manual does state MC4 connector pairs are internally parallel-connected to a single MPPT tracker.)
peak_efficiency_pct 98
self_consumption 12 V: 20 mA / 24 V: 15 mA / 48 V: 10 mA
temperature_compensation -16 mV / -32 mV / -64 mV / degC

Physical / mechanical

bracket_dimensions_mm 186 x 176 (dimension drawing outline)
depth_mm 70
dimensions_locator 'Dimensions (h x w x d) 130 x 186 x 70 mm'
enclosure_material UNKNOWN
height_mm 130
housing_color Blue (RAL 5012)
mounting_hole_diameter_mm R4 corner radius on the drawing
mounting_hole_spacing_mm 132 x 122
mounting_type ['wall']
power_terminals 16 mm2 / AWG6
shipping_weight_kg UNKNOWN
weight_kg 1.25
width_mm 186
wire_cross_section_mm2 16 mm2 / AWG6

Installation

altitude_derating_note 5000m (full rated output up to 2000m)
indoor_outdoor Indoor type 1, unconditioned
max_installation_altitude_m 5000
mounting_orientation UNKNOWN

Environment

cooling_method UNKNOWN (no fan row published)
ip_rating IP43 (electronic), IP22 (connection area)
max_altitude_m 5000
nema_rating UNKNOWN
operating_temperature_c -30 to +60 (full rated output up to 40)
pollution_degree PD2
relative_humidity 95 %, non-condensing
storage_temperature_c UNKNOWN

Interfaces & connectors

battery_terminal_type screw terminal, 16 mm2 / AWG6
bluetooth No - not built in. BlueSolar datasheet: 'VE.Direct Bluetooth Smart dongle needed'
ethernet UNKNOWN
load_output False
pv_connector_type screw terminal, 16 mm2 / AWG6
relay_outputs UNKNOWN (not published for this family)
remote_on_off UNKNOWN
rs485 UNKNOWN
ve_can False
ve_direct Yes - 1 x VE.Direct port
wifi UNKNOWN

Protection

over_temperature Yes
over_voltage UNKNOWN
pv_reverse_polarity Yes
short_circuit Output short circuit
under_voltage UNKNOWN

Certifications

standards ['EN/IEC 62109-1', 'UL 1741', 'CSA C22.2 NO.107.1-16', 'Kiwa Primara certificate 15-057-02, IEC 62109-1:2010 / EN 62109-1:2010, issued 2021-04-26, applicant Victron Energy B.V., De Paal 35, 1351 JG Almere, The Netherlands']

Warranty & service

summary UNKNOWN

Documents

certificate Certificate Safety EN/IEC 62109-1 — BlueSolar & SmartSolar MPPT 100/50, 150/35 & 150/45 (Kiwa Primara 15-057-02)
datasheet BlueSolar Charge Controller MPPT 150/35 & 150/45 — datasheet
dimension-drawing Dimension drawing BlueSolar & SmartSolar MPPT 100/50, 150/35, 150/45

Recorded conflicts

electrical.max_pv_open_circuit_voltage_v / mppt_operating_voltage_max_v Review required
150 V absolute maximum coldest conditions; 145 V start-up and operating maximum — document[0]
150 V absolute; 145 V operating maximum — document[0]

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Advanced partial shading detectionBlueSolar / SmartSolar MPPT algorithm feature
ColourBlue (RAL 5012)
Environmental conditionIndoor type 1, unconditioned
Internal temperature sensorYes
Pollution degreePD2

Build a system with this product