Identity

category external_mppt_controllers
ean —
generation —
manufacturer Victron Energy B.V. disputed
market_version —
model BlueSolar MPPT 250/70-Tr VE.Can
mpn —
product_family BlueSolar MPPT 250/70 up to 250/100 VE.Can
product_status active
region global
release_year —
sku —
variant_note Sold as -Tr (screw terminal) and -MC4 variants with different part numbers, dimensions and PV terminals; electrical specification is shared.

Electrical

battery_voltage_auto_select 12 / 24 / 48 V auto select; 36 V manual select
battery_voltage_locator 'Battery voltage 12/24/48 V Auto Select (36 V: manual)'
battery_voltage_nominal_v 12/24/36/48V Auto
battery_voltage_options_v [12, 24, 36, 48]
charge_algorithm Multi-stage adaptive (eight pre-programmed algorithms) or user defined
charge_voltage_absorption_v 14.4 / 28.8 / 43.2 / 57.6 V (adjustable)
charge_voltage_equalization_v 16.2 / 32.4 / 48.6 / 64.8 V (adjustable); disabled by default
charge_voltage_float_v 13.8 / 27.6 / 41.4 / 55.2 V (adjustable)
load_output_continuous_current_a none - this model has no load output
max_charge_current_a 70
max_charge_current_locator Datasheet 'Rated charge current'; manual 'Maximum battery current'
max_efficiency_pct 98.0
max_pv_current_per_mc4_connector_a 30
max_pv_current_per_mc4_connector_locator 'Maximum current per MC4 connector is 30A' - per-connector limit, NOT the array short-circuit rating
max_pv_open_circuit_voltage_locator 'Max. PV Open circuit Voltage (absolute maximum)' = 250 V - 'absolute maximum coldest conditions'
max_pv_open_circuit_voltage_v 250
max_pv_power_locator 'Nominal PV power, 12 V / 24 V / 36 V / 48 V'
max_pv_power_w_by_battery_voltage {'12': 1000, '24': 2000, '36': 3000, '48': 4000}
max_pv_short_circuit_current_a 35
max_pv_short_circuit_current_datasheet_a 35
max_pv_short_circuit_current_manual_a 35
mppt_operating_voltage_max_locator 'Max. PV Open circuit Voltage (start-up/operating)' = 245 V
mppt_operating_voltage_max_v 245
mppt_operating_voltage_min_note 'The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter minimum PV voltage is Vbat + 1V.'
num_trackers 1
num_trackers_locator Manual: MC4 connectors are internally parallel-connected to a single MPPT tracker
official_product_url https://www.victronenergy.com/solar-charge-controllers/bluesolar-mppt-150-35
BlueSolar MPPT 250/70 up to 250/100 VE.Can — Victron Energy product page
parallel_operation Yes, parallel synchronised operation via VE.Can (max. 25 units) or Bluetooth (max. 10 units)
peak_efficiency_pct 99
self_consumption less than 35 mA @ 12 V / 20 mA @ 48 V
temperature_compensation -16 mV/degC / -32 mV/degC / -48 mV/degC / -64 mV/degC (manual); datasheet prints -16 / -32 / -64 mV/degC

Physical / mechanical

bracket_dimensions_mm 249 x 227 x 101 (MC4 VE.Can L dimension drawing outline)
depth_mm 95
dimensions_locator 'Dimensions (h x w x d)': Tr 185x250x95 mm; MC4 215x250x95 mm
enclosure_material —
height_mm {'Tr': 185, 'MC4': 215}
housing_color Blue (RAL 5012)
mounting_hole_spacing_mm —
mounting_type ['wall']
power_terminals PV: 35 mm2 / AWG2 (Tr) or 2 pairs of MC4 connectors (MC4). Battery: 35 mm2 / AWG2
shipping_weight_kg —
weight_kg 3
width_mm 250
wire_cross_section_mm2 35 mm2 / AWG2

Installation

altitude_derating_note 5000m (full rated output up to 2000m)
indoor_outdoor Indoor, unconditioned
max_installation_altitude_m 5000
mounting_orientation —

Environment

cooling_method —
ip_rating IP43 (electronic components), IP22 (connection area)
max_altitude_m 5000
nema_rating —
operating_temperature_c -30 to +60 (full rated output up to 40)
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0
pollution_degree PD3
relative_humidity 95 %, non-condensing
storage_temperature_c —

Interfaces & connectors

battery_terminal_type screw terminal, 35 mm2 / AWG2
bluetooth No - not built in. BlueSolar datasheet 'Data communication: VE.Direct and VE.Can'; the manual's data-communication row does not list Bluetooth
communication VE.Direct / Bluetooth
ethernet —
load_output False
programmable_relay True
pv_connector_type Tr: screw terminal 35 mm2 / AWG2. MC4: 2 pairs of MC4 connectors
relay_outputs 1 programmable relay, DPST - AC rating 240 VAC / 4 A; DC rating 4 A up to 35 VDC, 1 A up to 60 VDC
remote_on_off Yes, 2-pole connector
rs485 —
ve_can Yes - 2 x paralleled RJ45 VE.Can ports
ve_direct Yes - VE.Direct port
wifi —

Protection

over_temperature Yes
over_voltage —
pv_reverse_polarity Yes
short_circuit Output short circuit
under_voltage —

Certifications

standards ['EN/IEC 62109-1', 'UL 1741', 'CSA C22.2 NO.107.1-16']

Warranty & service

summary —

Documents

datasheet BlueSolar Charge Controller MPPT 250/70, 150/100 & 250/100 VE.Can — datasheet
dimension-drawing Dimension drawing SmartSolar MPPT 150/250-70 MC4 VE.Can (L)
product_page BlueSolar MPPT 250/70 up to 250/100 VE.Can — Victron Energy product page
user-manual MPPT solar charger manual BlueSolar MPPT 150/70 up to 250/100 VE.Can — 9. Technical specifications

Recorded conflicts

electrical.max_pv_short_circuit_current_a (cross-family) Review required
35 — document[0]
70 —
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import wave6-2026-09-batch10
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import v1-freeze-2026-09-batch06
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import v1-freeze-2026-09-batch06
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import system-topology-2026-09-batch02
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import image-completion-2026-09-batch02

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Environmental conditionIndoor, unconditioned
Parallel operationYes, parallel synchronised operation with VE.Can (max. 25 units)
Pollution degreePD3
Programmable relayDPST AC rating: 240 VAC / 4 A; DC rating 4 A up to 35 VDC, 1 A up to 60 VDC
builder_completenesspartial