Knowledge Base › External MPPT Controllers
Victron Energy SmartSolar MPPT 100/15
Official manufacturer GLOBAL verified Sept. 20, 2026
Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Identity
| category | external_mppt_controllers |
| ean | — |
| generation | — |
| manufacturer | Victron Energy B.V. disputed |
| market_version | — |
| model | SmartSolar MPPT 100/15 |
| mpn | SCC110015060R |
| product_family | SmartSolar MPPT 75/10, 75/15, 100/15 & 100/20 |
| product_status | active |
| region | global |
| release_year | — |
| sku | SCC110015060R |
| sku_source | 'SCC110015060R SmartSolar MPPT 100/15 Retail' |
Electrical
| automatic_load_disconnect | Yes |
| battery_voltage_auto_select | True |
| battery_voltage_locator | 'Battery voltage (auto select)' |
| battery_voltage_nominal_v | 12/24V Auto |
| battery_voltage_options_v | [12, 24] |
| charge_algorithm | Multi-stage adaptive or user defined |
| charge_voltage_absorption_v | 14.4 / 28.8 V (adjustable) |
| charge_voltage_equalization_v | 16.2V / 32.4V / 64.8V (adjustable) - manual; equalization is by default disabled (manual footnote 3) |
| charge_voltage_float_v | 13.8 / 27.6 V (adjustable) |
| load_output_continuous_current_a | 15A |
| load_output_locator | Manual §9 'Continuous load current' |
| low_voltage_load_disconnect_v | 11.1V / 22.2V / 44.4V or 11.8V / 23.6V / 47.2V or BatteryLife |
| low_voltage_load_reconnect_v | 13.1V / 26.2V / 52.4V or 14V / 28V / 56V or BatteryLife |
| max_charge_current_a | 15 |
| max_charge_current_locator | Datasheet 'Rated charge current'; manual 'Maximum battery current' |
| max_efficiency_pct | 98.0 |
| max_pv_open_circuit_voltage_locator | 'Maximum PV open circuit voltage' = 100 V (no separate start-up/operating maximum is published for this family) |
| max_pv_open_circuit_voltage_v | 100 |
| max_pv_power_locator | 'Nominal PV power, 12 V' / 'Nominal PV power, 24 V' |
| max_pv_power_note | Manual footnote 1a: 'The solar charger will limit input power if more PV power is connected.' |
| max_pv_power_w_by_battery_voltage | {'12': 220, '24': 440} |
| max_pv_short_circuit_current_a | 15 |
| max_pv_short_circuit_current_datasheet_a | 15 |
| max_pv_short_circuit_current_manual_a | 15 |
| mppt_operating_voltage_max_v | — |
| mppt_operating_voltage_min_note | Manual footnote 1b: 'The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.' |
| num_trackers | — |
| num_trackers_note | Victron does not publish a 'number of MPP trackers' row for this model in any document fetched this session; the unit has a single PV input pair. Recorded as UNKNOWN rather than assumed. (For the 150/60 and larger families the manual does state MC4 connector pairs are internally parallel-connected to a single MPPT tracker.) |
| peak_efficiency_pct | 98 |
| self_consumption_datasheet | 26 / 20 / 19 mA (load on); 10 / 8 / 7 mA (load off) |
| self_consumption_manual | 12V: 20mA / 24V: 10mA |
| temperature_compensation | -16 mV/degC (12V) / -32 mV/degC (24V) |
Physical / mechanical
| depth_mm | 50 |
| dimensions_locator | 'Dimensions (h x w x d)' |
| enclosure_material | — |
| height_mm | 100 |
| housing_color | Blue (RAL 5012) |
| mounting_type | ['wall'] |
| power_terminals | 6 mm2 / AWG10 |
| shipping_weight_kg | — |
| torque_specs | — |
| weight_kg | 0.6 |
| width_mm | 113 |
| wire_cross_section_mm2 | 6 mm2 / AWG10 |
Installation
| altitude_derating_note | 5000m (full rated output up to 2000m) |
| indoor_outdoor | Indoor type 1, unconditioned (manual 'Environmental condition') |
| max_installation_altitude_m | 5000 |
| mounting_orientation | — |
Environment
| cooling_method | — |
| ip_rating | IP43 (electronic), IP22 (connection area) |
| max_altitude_m | 5000 |
| nema_rating | — |
| operating_temperature_c | -30 to +60 (full rated output up to 40) |
| operating_temperature_max_c | 60.0 |
| operating_temperature_min_c | -25.0 |
| pollution_degree | PD3 |
| relative_humidity | CONFLICT - 95% (datasheet) vs 100% (manual), both non-condensing |
| storage_temperature_c | — |
Interfaces & connectors
| battery_terminal_type | screw terminal, 6 mm2 / AWG10 |
| bluetooth | Yes - built in (SmartSolar); 'VE.Direct port, Bluetooth via VictronConnect app' |
| communication | VE.Direct / Bluetooth |
| ethernet | — |
| load_output | Yes - 15A continuous load current with automatic load disconnect / BatteryLife |
| pv_connector_type | screw terminal, 6 mm2 / AWG10 |
| relay_outputs | — |
| remote_on_off | — |
| rs485 | — |
| ve_can | False |
| ve_direct | Yes - 1 x VE.Direct port |
| wifi | — |
Protection
| over_temperature | Yes |
| over_voltage | — |
| pv_reverse_polarity | Yes |
| short_circuit | Output short circuit |
| under_voltage | — |
Certifications
| standards | ['EN/IEC 62109-1', 'UL 1741', 'CSA C22.2 NO.107.1-16'] |
Warranty & service
| summary | — |
Documents
dimension-drawing
Dimension drawing BlueSolar & SmartSolar MPPT 100/15
Recorded conflicts
battery_voltage_classes Review required
[12, 24, 48] —
[12, 24] —
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import system-topology-2026-09-batch02
physical.weight_kg / physical.dimensions Review required
0.65 kg, 100 x 131 x 60 mm — document[0]
0.6 kg, 100 x 113 x 50 mm — document[1]
electrical.self_consumption Review required
26 / 20 / 19 mA (load on); 10 / 8 / 7 mA (load off) — document[0]
12V: 20mA / 24V: 10mA — document[1]
environment.relative_humidity Review required
95 %, non-condensing — document[0]
100%, non-condensing — document[1]
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| 1b) | The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V. |
| 2) | A higher short circuit current may damage the solar charger in case of reverse polarity connection. |
| 3) | Equalization is by default disabled. |
| Automatic load disconnect | Yes |
| Environmental condition | Indoor type 1, unconditioned |
| Low voltage load disconnect | 11.1V / 22.2V / 44.4V or 11.8V / 23.6V / 47.2V or BatteryLife |
| Low voltage load reconnect | 13.1V / 26.2V / 52.4V or 14V / 28V / 56V or BatteryLife |
| Pollution degree | PD3 |