⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Gateways / Data Loggers

HMS Networks Anybus Communicator - Serial Master to Modbus TCP slave

Manufacturer documented GLOBAL

Identity

category gateways
manufacturer HMS Networks
manufacturer_part_number ABC3028-A
model Anybus Communicator - Serial Master to Modbus TCP slave
mpn ABC3028-A
product_family Anybus Communicator (gen 2)
product_status active
region GLOBAL
series Anybus Communicator
variant —

Electrical

country_of_origin Sweden
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Identification and Status, row 'Country of Origin'
current_consumption_max 125 mA @ 24 V DC (3 W)
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Current Consumption Max value at Vcc nom (mA)'
current_consumption_typical 90 mA @ 24 V DC (2.2 W)
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Current Consumption Type Value at Vcc Nom (mA)'
galvanic_isolation TRUE (the datasheet prints only the boolean 'Isolation: TRUE'; no test voltage and no isolated-domain list is printed)
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Isolation'
input_voltage_v 12-30 V DC
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Input Voltage (V)'
model_code 40-SER-ETH-B
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Identification and Status, row 'Model Code'
power_connector 3-pin, 5.08 Phoenix plug connector
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Power Connector'
predecessor_models AB7028-C; AB7028-C-5PACK
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Identification and Status, row 'Predecessor'
product_id ABC3028-A
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General / Identification and Status, row 'Product ID'
reset_button Factory reset push button
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Physical Features, row 'Push Buttons'
supply_voltage 100-240 V AC
warranty_years 5 years
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Warranty (years)'

Physical / mechanical

dimensions_mm 27 x 144 x 98 (W x H x D) mm
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, rows 'Net Width/Height/Depth (mm)'
housing_material PC ABS, UL 94 V0
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Housing Materials'
weight_g 150 g
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Net Weight (g)'

Installation

mounting DIN-rail (EN 50022 standard)
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Mounting'

Environment

ip_rating IP20
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Certifications and Standards, row 'Protection Class IP'
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0
operating_temperature_range_c -25 to +70 C
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, rows 'Operating Temperature C Min/Max'
storage_temperature_range_c -40 to +85 C
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, rows 'Storage Temperature C Min/Max'

Interfaces & connectors

device_type serial-to-Ethernet Modbus protocol gateway
ethernet_ports 2 x RJ45 (daisy chaining) plus a separate RJ45 configuration port
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Physical Features, row 'Connectors / Input / Output'
ethernet_speed 10/100 Mbit/s
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-TCP Features, row 'Modbus-TCP Bandwidth'
home_assistant_modbus_tcp_suitable True
home_assistant_suitability_basis The generated datasheet prints two separate role rows: 'Modbus-RTU Mode: Client / Master' (Serial Features / Modbus-RTU Features) and 'Modbus-TCP Mode: Slave / Server' (Modbus-TCP Features), with 4 concurrent Modbus TCP connections. The device therefore polls serial Modbus RTU slaves as master and presents the result to a standard Modbus TCP client as a server, which is what Home Assistant's modbus TCP integration needs. Caveat recorded from the same datasheet: this is a configured data-mapping gateway (fixed input/output data areas of 1500 bytes each), NOT a transparent request-forwarding RTU-over-TCP bridge - a Home Assistant client reads the gateway's mapped register area, not arbitrary slave registers. No default IP address and no Modbus TCP port number are printed on the datasheet.
interfaces RS485, Ethernet, Wi-Fi
max_modbus_tcp_connections 4
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-TCP Features, row 'Modbus-TCP Supported Functionality' ("4 connections")
modbus_rtu_data_size 1500 in / 1500 out bytes
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-RTU Features, rows 'Input Data Size' / 'Output Data Size'
modbus_rtu_functions 1, 2, 3, 4, 5, 6, 7, 8, 11, 12, 15, 16, 17, 20, 21, 22, 24
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-RTU Features, row 'Modbus-RTU Functions Supported'
modbus_rtu_role Client / Master (the gateway is the Modbus RTU master on the serial side)
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-RTU Features, row 'Modbus-RTU Mode'
modbus_tcp_functions 1, 2, 3, 4, 5, 6, 15, 16, 23, 43/14
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-TCP Features, row 'Modbus-TCP Functions Supported'
modbus_tcp_role Slave / Server (the gateway is the Modbus TCP server on the Ethernet side)
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-TCP Features, row 'Modbus-TCP Mode'
modbus_tcp_spec Modbus specification V1.1b3
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-TCP Features, row 'Modbus-TCP Supported Functionality'
rs232 true
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Serial Features, row 'Supported Functionality' (literal 'RS-232')
rs422 not stated - RS-422 is not named anywhere in the datasheet
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Serial Features, row 'Supported Functionality'
rs485 true
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Serial Features, row 'Supported Functionality' (literal 'RS485')
serial_baud_rates 1200; 1800; 2400; 4800; 7200; 9600; 14400; 19200; 35700; 38400; 57600; 115200; 128000 bit/s
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Serial Features, row 'Baud Rate'
serial_connector 1x 7-pin, 5.08 Phoenix plug connector
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Serial Features, row 'Connector'
serial_data_format 7 or 8 data bits; parity none/odd/even; 1 or 2 stop bits
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Modbus-RTU Features, row 'Modbus-RTU Supported Functionality'
serial_max_nodes 31
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Serial Features, rows 'Max Stations' and 'Max Nodes'
serial_port_count 1
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Physical Features, row 'Connectors / Input / Output'
serial_ports 1 x serial port on a 7-pin 5.08 mm pluggable screw connector; RS-232 and RS-485 named in the 'Supported Functionality' row. RS-422 is NOT named.
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Serial Features, rows 'Connector' and 'Supported Functionality'
supported_devices_max 32

Protection

reverse_polarity_protection Yes
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Reverse Polarity Protection'
short_circuit_protection Yes
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — General, row 'Short Circuit Protection'

Certifications

certifications CE, UL, KC, WEEE, EMC; UL file E214107 (UL 61010-1, CSA C22.2 No. 61010-1, UL 61010-2-201, CSA C22.2 No. 61010-2-201); EN 55016-2-3 Class A, EN 55032 Class A, EN 61000-4-2/-3/-4/-5/-6
HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave — Certifications and Standards + Environment

Documents

datasheet HMS generated datasheet (EN) - Anybus Communicator - Serial Master to Modbus TCP slave