ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseGateways / Data Loggers

Victron Energy Cerbo GX MK2

Official manufacturer global verified Sept. 2, 2026

Identity

category gateways
cpu UNKNOWN
generation second generation Cerbo GX, released 2023/2024
manufacturer Victron Energy B.V.
model Cerbo GX MK2
operating_system Venus OS
product_family GX (Venus OS communication centre / system monitoring)
product_status active
ram UNKNOWN
region global
sku BPP900450110 and BPP900451100 (identical products; difference is country of origin, India versus Malaysia)

Electrical

power_consumption_w UNKNOWN
pv_mppt_capability none - monitoring/control gateway only
supply_fuse inline 3.15 A slow-blow fuse included in supplied DC power cable
supply_voltage_range_v 8 - 70V DC

Physical / mechanical

dimensions_h_w_d_mm 78 x 154 x 48 mm
display no built-in display; optional GX Touch 50 / GX Touch 70
enclosure_material UNKNOWN
weight UNKNOWN

Installation

mounting Wall or DIN rail (35mm)
mounting_note DIN rail mounting requires additional accessory - DIN35 Adapter
power_in_port Power in port (8 - 70VDC)

Environment

humidity UNKNOWN
operating_temperature_range_c -20 to +50°C

Interfaces & connectors

bluetooth Bluetooth Smart - 2.402 - 2.48GHz | 5.2mW
bms_can_port No dedicated BMS-Can port; both VE.Can ports are fully configurable to multiple profiles including BMS-Can
digital_input_electrical Inputs are non-isolated. Each input includes an internal 10 kΩ pull-up resistor to 3.3 V. Can safely withstand input voltages up to 5 V.
digital_inputs 4 (with pulse counting)
ethernet 10/100 RJ45 socket - isolated except shield
hdmi HDMI port
microsd MicroSD Card Slot (max. 32GB)
modbus_tcp Yes - disabled by default; enabled under Settings -> Services
mqtt Yes - listed as a Settings -> Integrations item in the GX manual
relay_outputs 2 x NO/NC; DC up to 30VDC: 6A; DC up to 70VDC: 1A; AC: 6A, 125VAC
remote_console Yes
supported_protocols VE.Bus, VE.Direct, VE.Can (250 kbit/s), BMS-Can (500 kbit/s), RV-C, NMEA 2000, Modbus-TCP, MQTT, Marine MFD app integration, mDNS/SSDP/DNS-SD
tank_level_inputs 4 resistive; configurable European (0 - 180 Ohm), US (240 - 30 Ohm) or custom 0-300 Ohm
temperature_inputs 4 (requires ASS000001000 temperature sensor)
usb_ports 3x USB Host ports (fully functional)
ve_bus_ports 1 VE.Bus (2 paralleled RJ45 sockets)
ve_can_isolation VE.Can 1 isolated, VE.Can 2 non-isolated
ve_can_ports 2 - VE.Can 1: Yes - isolated; VE.Can 2: Yes - non-isolated
ve_can_profiles 2 x Fully configurable VE.Can ports supporting VE.Can (250 kbit/s), BMS-Can (500 kbit/s) and CAN-bus BMS profiles
ve_can_termination Terminate the VE.Can network at both ends using VE.Can terminator
ve_direct_ports 3 (max. possible VE.Direct devices: 15)
vrm Yes - VRM Portal data logging, default log interval 15 minutes
wifi WiFi 2.4GHz (802.11 b/g/n) incl. WiFi Access Point | Range: 2.412 - 2.462GHz | 88.1mW

Protection

ip_rating IP20

Certifications

standards ['Safety: IEC 62368-1', 'EMC: EN 301489-1, EN 301489-17', 'Automotive: ECE R10-6']

Warranty & service

summary 5-year standard warranty

Documents

installation-manual Cerbo GX Manual - 3. Installation (HTML5)
user-manual Cerbo GX Manual - 17. Digital Inputs (HTML5)
user-manual Cerbo GX Manual - 21. Technical specifications (HTML5), table 21.2 Cerbo GX MK2
user-manual Cerbo GX Manual - 5. Connecting Victron products (HTML5)
user-manual Victron GX product range (Venus OS comparison page, incl. footnote 26)

Recorded conflicts

interfaces.tank_level_inputs / interfaces.temperature_inputs / interfaces.digital_inputs Review required
4 resistive tank level inputs, 4 temperature sense inputs, 4 digital inputs (with pulse counting) — Cerbo GX Manual, table 21.2 Cerbo GX MK2 and 3. Installation 'Overview of connections - Cerbo GX MK2'
no tank level inputs, no temperature sense inputs, no digital inputs — Victron GX product range comparison table (venus-os:start) as rendered in one text-extraction pass

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

17. Digital Inputssecond-generation models: PN BPP900450110 and BPP900451100 support the Pulse Meter function
documented_relationship:gateway_device{"to_manufacturer": "Victron Energy", "to_model": "MultiPlus / Quattro / VE.Bus inverter-chargers", "relationship_type": "gateway_device", "bus": "VE.Bus", "source": "Cerbo GX Manual 5.1", "source_url": "https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html", "confidence": "officially-verified"}
footnote 22The digital inputs on the Ekrano GX, Cerbo GX MK2 and Venus GX can also be used for pulse counting. The digital inputs on the Cerbo GX and other devices are not able to do pulse counting.
footnote 26 (application note)The Cerbo GX MK2 revision is most valuable for some very specific applications. Such as the RV market in the US where a Lynx Smart BMS is installed, requires a VE.Can connection, as well as an RV-C port is required. And VE.Can and RV-C can not run on the same CAN network. Also for marine installations it offers an advantage when integrated into the NMEA2000 network, due to the VE.Can 1 port being galvanically isolated.
footnote 26 (differences vs first generation Cerbo GX)It has the same enclosure and almost the same electronics design; except for (A) two fully functional CAN bus ports, called VE.Can 1 and VE.Can 2. Instead of one VE.Can and one dedicated BMS-Can port. And on the MK2 model, VE.Can 1 is isolated. On previous models, there was no isolated canbus port. All VE.Can ports can be configured to multiple profiles, including BMS-Can. (B) the RJ-45 sockets have been rotated 180 degrees, so its easier to take the cables out. (C) All three USB ports are fully functional. Instead of two functional and one for power, to a GX Touch, only. (D) Digital inputs can do pulse counting.

Build a system with this product