ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseGateways / Data Loggers

Victron Energy Cerbo-S GX

Official manufacturer global verified Sept. 2, 2026

Identity

category gateways
cpu UNKNOWN
manufacturer Victron Energy B.V.
model Cerbo-S GX
operating_system Venus OS
product_family GX (Venus OS communication centre / system monitoring)
product_status UNKNOWN
ram UNKNOWN
region global
sku BPP900450120
sku_confidence distributor-verified

Electrical

power_consumption_w UNKNOWN
pv_mppt_capability none - monitoring/control gateway only
supply_fuse UNKNOWN
supply_voltage_range_v 8 - 70V DC

Physical / mechanical

dimensions_h_w_d_mm 78 x 154 x 48 mm
display no built-in display
enclosure_material UNKNOWN
weight UNKNOWN

Installation

mounting Wall or DIN rail (35mm)

Environment

humidity UNKNOWN
operating_temperature_range_c -20 to +50°C

Interfaces & connectors

bluetooth Yes - 2.402 - 2.48GHz | 5.2mW
bms_can_port No
digital_inputs 4
ethernet UNKNOWN
modbus_tcp Yes - disabled by default; enabled under Settings -> Services
mqtt Yes - listed as a Settings -> Integrations item in the GX manual
relay_outputs 2 x NO/NC; DC up to 30VDC: 6A; DC up to 70VDC: 1A; AC: 6A, 125VAC
remote_console Yes
supported_protocols VE.Bus, VE.Direct, VE.Can, Modbus-TCP, MQTT, NMEA 2000, Marine MFD app integration
tank_level_inputs 0
temperature_inputs 0
usb_ports UNKNOWN
ve_bus_ports 1 VE.Bus (2 paralleled RJ45 sockets)
ve_can_ports 1 - Yes, non isolated
ve_direct_ports 3 (max. possible VE.Direct devices: 15)
vrm Yes
wifi Yes - 2.4GHz Wifi | Range: 2.412 - 2.462GHz | 88.1mW

Protection

ip_rating IP20

Certifications

standards ['Safety: IEC 62368-1', 'EMC: EN 301489-1, EN 301489-17', 'Automotive: ECE R10-6']

Warranty & service

summary 5-year standard warranty

Documents

user-manual Cerbo-S GX Manual - 21. Technical specifications (HTML5)
user-manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Ekrano GX / Venus GX / Cerbo GX / Cerbo-S GX Manual (PDF) — located, not retrieved
user-manual Victron GX product range (Venus OS comparison page, incl. footnotes)

Recorded conflicts

interfaces.ve_direct_ports / interfaces.relay_outputs / interfaces.digital_inputs Review required
VE.Direct ports: 3; Relays: 2 x NO/NC (6A @ 30VDC); Digital inputs: 4 — Cerbo-S GX Manual, 21. Technical specifications, table headed 'Cerbo-S GX'
VE.Direct ports: 2; Programmable relay: 1 x NO; Digital Inputs: no — Victron GX product range comparison table (venus-os:start)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Distributor product titleVictron Cerbo-S GX Basic Version - Limited Inputs No BMS Can Port - P/N BPP900450120
documented_relationship:gateway_device{"to_manufacturer": "Victron Energy", "to_model": "MultiPlus / Quattro / VE.Bus inverter-chargers", "relationship_type": "gateway_device", "bus": "VE.Bus", "source": "Ekrano GX / Venus GX / Cerbo GX / Cerbo-S GX Manual, 5. Connecting Victron products", "source_url": "https://www.victronenergy.com/media/pg/Cerbo_GX/en/connecting-victron-products.html", "confidence": "officially-verified"}
footnote 17Also note that this limitation does not apply to the Cerbo-S GX.