| ac_output |
{'rated_output_power_va': [1500, 3000], 'ac_input_voltage_v': 230, 'selectable_voltage_range_v': '90~280 (appliances) / 170~280 (PCs)', 'ac_output_voltage_regulation_v': '230±5%', 'surge_power_va': [3000, 6400], 'waveform': 'Pure sine wave', 'transfer_time_ms': '10 (PCs) / 20 (appliances)', 'power_factor': 1.0, 'frequency_Hz': '50/60'}
|
| battery |
{'voltage_options_v': [12, 24], 'floating_charge_voltage_v': [13.5, 27], 'overcharge_protection_v': [16, 33], 'max_ac_charge_current_a': 60}
|
| dc_input |
{'mppt_voltage_range_v': '90~430', 'max_pv_open_circuit_voltage_v': 450, 'max_pv_power_w': [2000, 3000], 'max_charging_current_a': 80}
|
| efficiency |
{'pv_to_inv_peak_pct': 98, 'battery_to_inv_peak_pct': 94}
|
| models |
['HY1512M', 'HY3022MNL']
|
| phase_count |
single-phase
|
| type |
hybrid (off-grid/grid-tie)
|