CHINT CPS SCH100KTL-DO/US-600
Official manufacturer US verified Sept. 25, 2026
Identity
| category | inverters |
| manufacturer | CHINT |
| model | CPS SCH100KTL-DO/US-600 |
| product_status | active |
| region | US |
| variant | 3-phase |
Electrical
| ac_voltage_v |
600
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| battery_supported | True |
| cec_efficiency_percent |
98.5
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| dc_input_voltage_range |
860-1450 Vdc
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| dimensions_in |
45.28 x 24.25 x 9.84
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| eps_backup_power_w | 100000.0 |
| euro_efficiency_pct | 98.2 |
| max_ac_active_power_w | 100000.0 |
| max_ac_apparent_power_kva |
111
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| max_ac_apparent_power_va | 100000.0 |
| max_ac_current_a |
106.8
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| max_dc_current_a |
118
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| max_efficiency_pct | 98.6 |
| max_efficiency_percent |
99.1
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| max_input_current_per_mppt_a | 26.0 |
| max_pv_power_kw |
187.5
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| max_pv_voltage_v |
1500
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| max_short_circuit_current_a |
220
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| max_short_circuit_current_per_mppt_a | 39.0 |
| mppt_count | 6 |
| mppt_voltage_max_v |
1300
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| mppt_voltage_min_v |
870
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| nominal_ac_voltage_v | 400.0 |
| nominal_frequency_hz | 50.0 |
| number_of_mppt |
1
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| phase_count |
3
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| rated_ac_power_kw |
100
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| rated_ac_power_w | 100000.0 |
| startup_voltage_v |
900
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| transfer_time_ms | 20.0 |
| weight_lb |
121
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
Environment
| ip_rating | IP65 |
| operating_temperature_max_c | 60.0 |
| operating_temperature_min_c | -25.0 |
Interfaces & connectors
| communications |
['Modbus RS485']
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| protocols |
['Modbus RTU']
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
Protection
| ac_surge_protection |
Type II MOV
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
| dc_surge_protection |
Type II MOV
CPS SCH100KTL-DO/US-600 & CPS SCH125KTL-DO/US-600 datasheet (8-21-2026)
|
Warranty & service
| warranty_years | 10 |
Documents
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| builder_completeness | partial |
| region_notes | North-American 600 Vac product; the datasheet is the Chint Power Systems America US edition. ANMA stores this brand as 'CHINT'. |