EG4 EG4 FlexBOSS21
Official manufacturer NA verified Sept. 25, 2026
Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Identity
| category | inverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | — |
| manufacturer | EG4 |
| market_version | NA (UL 1741 / split-phase 120/240 VAC) |
| model | EG4 FlexBOSS21 |
| mpn | IV-16000-HYB-AW-FX-XX |
| product_family | FlexBOSS |
| product_status | — |
| region | — |
| release_year | — |
| series | FlexBOSS |
| sku | IV-16000-HYB-AW-FX-XX |
Electrical
| ac_connection | 1ø |
| ac_voltage_range | — |
| battery_capacity_range_kwh | — |
| battery_communication | — |
| battery_max_charge_current_a | 250 |
| battery_max_charge_power_w | — |
| battery_max_discharge_current_a | 250 |
| battery_max_discharge_power_w | — |
| battery_nominal_battery_voltage_v | 51.2 |
| battery_nominal_voltage_v |
51.2
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| battery_supported |
True
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| battery_type | — |
| battery_voltage_max_v |
60
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| battery_voltage_min_v |
40
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| battery_voltage_range_v | 40 - 60 VDC |
| cec_weighted_efficiency_pct | 97 |
| eps_peak_power | 24000W (.5 sec) | 18000W (1 sec) | 15000W (6 min) | 13200W (12 min) |
| eps_phase | — |
| eps_rated_power_va | — |
| eps_switchover_time_ms | 20ms (Default), 10ms (Configurable) |
| eps_voltage | — |
| european_efficiency_pct | — |
| external_transfer_switch_required | — |
| frequency_range_hz | 50/60Hz |
| inrush_current | — |
| max_ac_active_power_w | 16kW (rated continuous); 12kW (battery only) |
| max_ac_current_a | 66.7 |
| max_ac_power_w |
16000
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| max_apparent_power_va | 16000 |
| max_backfeed_current_a | — |
| max_charge_current_a |
250
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| max_dc_input_power_w | 21000 |
| max_dc_voltage_v | 600 |
| max_discharge_current_a |
250
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| max_efficiency_pct | 97 |
| max_input_current_per_mppt_a | 26A (MPPT 1) | 26A (MPPT 2) | 15A (MPPT 3) disputed |
| max_output_fault_current_a | — |
| max_pass_through_current_a | 90 |
| max_pv_input_voltage_v |
600
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| max_short_circuit_current_per_mppt_a | 31A (MPPT 1) | 31A (MPPT 2) | 19A (MPPT 3) disputed |
| mppt_efficiency_pct | — |
| mppt_voltage_max_v |
440
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| mppt_voltage_min_v |
120
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| mppt_voltage_range_v | 250 - 440 VDC (full power) |
| night_self_consumption_w | — |
| nominal_ac_voltage | 120/240 or 208 VAC |
| nominal_dc_voltage_v | — |
| nominal_frequency_hz | — |
| nominal_grid_voltage_v |
['120/240', '120/208']
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| number_of_mppt |
3
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| official_manual_url |
https://eg4electronics.com/wp-content/uploads/2024/08/FlexBOSS-21-Manual.pdf
EG4 FlexBOSS21 product page
|
| official_product_url |
https://eg4electronics.com/categories/inverters/eg4-flexboss-21/
EG4 FlexBOSS21 product page
|
| parallel_capability | 16 |
| phase_count |
1
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| power_factor_range | — |
| product_status |
active
EG4 FlexBOSS21 product page
|
| rated_ac_power_w | 16000 |
| rated_mppt_voltage_range_v | — |
| startup_voltage_v |
200
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| strings_per_mppt | 2 (MPPT 1) / 2 (MPPT 2) / 1 (MPPT 3) |
| strings_per_mppt_distribution |
[2, 2, 1]
EG4 FlexBOSS21 Hybrid Inverter Spec Sheet
|
| thd_pct | — |
Physical / mechanical
| ac_terminal | — |
| cooling | — |
| dc_connector | — |
| depth_mm | 285 |
| dimensions_mm | 773 x 566 x 285 |
| display | — |
| enclosure_material | — |
| height_mm | 773 |
| mounting | — |
| noise_db | — |
| weight_kg | 55 |
| width_mm | 566 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | NEMA 4X |
| max_altitude_m | — |
| operating_temperature_c | -25° - 60°C |
| pollution_degree | — |
| protective_class | — |
| relative_humidity_pct | — |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | ['Wi-Fi', 'Cellular', 'Ethernet'] |
| dry_contact | — |
| meter_interface | — |
| monitoring_portal | — |
| protocols | [] |
Protection
| anti_islanding | — |
| arc_fault | — |
| dc_switch | — |
| insulation_monitoring | — |
| overvoltage_category | — |
| rcmu | — |
| reverse_polarity | — |
| surge_protection_ac | — |
| surge_protection_dc | — |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | 10 |
Documents
installation_manual
EG4 FlexBOSS21 Hybrid Inverter User Manual, Version 1.3.7 (model IV-16000-HYB-AW-FX-XX)
product_page
EG4 FlexBOSS21 product page
Recorded conflicts
electrical.max_short_circuit_current_per_mppt_a Review required
31A (MPPT 1) | 31A (MPPT 2) | 19A (MPPT 3) — stored value
[31, 31, 19] — SHORT-CIRCUIT CURRENT RATING PER MPPT 31A (MPPT 1) | 31A (MPPT 2) | 19A (MPPT 3) — axis: MPPT
Detected during import v1-freeze-2026-09-batch07
electrical.max_input_current_per_mppt_a Review required
26A (MPPT 1) | 26A (MPPT 2) | 15A (MPPT 3) — stored value
[26, 26, 15] — RATED CURRENT PER MPPT 26A (MPPT 1) | 26A (MPPT 2) | 15A (MPPT 3) — axis: MPPT
Detected during import v1-freeze-2026-09-batch07
electrical.max_ac_current_a Resolved — accepted incoming value
66.7A (rated continuous) | 50A (battery only) — stored value
66.7 — MAX. CONTINUOUS OUTPUT 66.7A | 16kW
Detected during import v1-freeze-2026-09-batch07
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| CEC WEIGHTED EFFICIENCY | 97% |
| MAX. APPARENT POWER WITH BATTERY | 12kVA |
| NOMINAL VOLTAGE | 51.2 VDC |
| RATED CURRENT PER MPPT | 26A (MPPT 1) | 26A (MPPT 2) | 15A (MPPT 3) |
| SHORT-CIRCUIT CURRENT RATING PER MPPT | 31A (MPPT 1) | 31A (MPPT 2) | 19A (MPPT 3) |
| battery.communication | UNKNOWN |
| battery.max_charge_current_a | 250 |
| battery.max_charge_power_w | UNKNOWN |
| battery.max_discharge_current_a | 250 |
| battery.max_discharge_power_w | UNKNOWN |
| battery.nominal_battery_voltage_v | 51.2 |
| builder_completeness | partial |