Identity
| brand | Fronius |
| category | inverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | GEN24 |
| manufacturer | Fronius |
| manufacturer_key | fronius |
| market_version | International help-center page; standards listed span IEC, AS/NZS 4777.2, CEI 0-21 and ABNT |
| model | Primo GEN24 3.0 Plus |
| model_key | primogen2430plus |
| mpn | — |
| product_family | Primo GEN24 Plus |
| product_status | active |
| region | GLOBAL |
| release_year | — |
| series | GEN24 |
| sku | 4,210,140,002 |
Electrical
| ac_connection | 3 pole AC push-in spring terminals 2.5 - 10 mm²; 3 pole backup power push-in spring terminals 1.5mm² - 10mm² |
| ac_voltage_range | 155 - 270 V |
| battery_capacity_range_kwh | — |
| battery_communication | — |
| battery_max_charge_current_a | 22 |
| battery_max_charge_power_w | 3110 |
| battery_max_discharge_current_a | — |
| battery_max_discharge_power_w | 3110 |
| battery_nominal_battery_voltage_v | — |
| battery_type | — |
| battery_voltage_range_v | 150 V - 455 V |
| eps_peak_power | — |
| eps_phase | 1~ |
| eps_rated_power_va | 3000 |
| eps_switchover_time_ms | — |
| eps_voltage | 1~ NPE 220 V / 230 V |
| european_efficiency_pct | 96.7 / 97.5 / 97.3 (190Vdc / 400Vdc / 530Vdc) |
| external_transfer_switch_required | — |
| frequency_range_hz | 45 - 65 Hz |
| inrush_current | — |
| max_ac_active_power_w | — |
| max_ac_current_a | 19.4 |
| max_ac_power_va |
3000
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| max_apparent_power_va | 3000 |
| max_backfeed_current_a | — |
| max_dc_input_power_w | 3110 |
| max_dc_voltage_v | 600 |
| max_efficiency_pct | 97.6 |
| max_input_current_per_mppt_a | 22 / 12 disputed |
| max_output_fault_current_a | — |
| max_pv_input_voltage_v |
600
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| max_short_circuit_current_per_mppt_a | 41.25 / 22 disputed |
| mppt_efficiency_pct | >99.9 |
| mppt_voltage_max_v |
530
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| mppt_voltage_min_v |
190
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| mppt_voltage_range_v | 190 - 530 V |
| night_self_consumption_w | < 10 |
| nominal_ac_voltage | 1~ NPE 220/230 V |
| nominal_dc_voltage_v | 400 |
| nominal_frequency_hz | 50 / 60 |
| nominal_grid_voltage_v |
230
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| number_of_mppt | 2 |
| parallel_capability | — |
| phase_count |
1
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| power_factor_range | 0.8 - 1 ind./cap. |
| rated_ac_power_w |
3000
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| rated_mppt_voltage_range_v | 65 - 530 V |
| startup_voltage_v |
80
Fronius Primo GEN24 3.0 Plus (help centre technical data)
|
| strings_per_mppt | 2+2 DC connections |
| thd_pct | — |
Physical / mechanical
| ac_terminal | 3 pole AC push-in spring terminals 2.5 - 10 mm² |
| cooling | Regulated air cooling |
| dc_connector | 4x DC+ and 4x DC- push-in spring terminals 2.5 - 10 mm² |
| depth_mm | — |
| dimensions_mm | — |
| display | — |
| enclosure_material | — |
| height_mm | — |
| mounting | — |
| noise_db | 42 |
| weight_kg | 15.38 |
| width_mm | — |
Installation
| cable_requirements | DC PV: 4x DC+ / 4x DC- push-in spring terminals 2.5 - 10 mm²; DC battery: 1x BATT+ / 1x BATT- push-in spring terminals 2.5 - 10 mm² |
| commissioning | — |
| installation_angle | — |
| location | Indoor and outdoor |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP66 |
| max_altitude_m | 4000 |
| operating_temperature_c | -40°C - +60°C |
| pollution_degree | — |
| protective_class | 1 |
| relative_humidity_pct | 0 - 100% |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | ['WLAN', '2x Ethernet LAN', '2x RS485', '6x digital in/out + 6x digital in', 'Emergency stop (WSD)'] |
| dry_contact | — |
| meter_interface | 2x RS485: Modbus RTU SunSpec / Fronius Smart Meter |
| monitoring_portal | Fronius Solar.web |
| protocols | ['Modbus TCP SunSpec', 'Fronius Solar API (JSON)', 'Modbus RTU SunSpec'] |
Protection
| anti_islanding | — |
| arc_fault | — |
| dc_switch | Yes (integrated DC disconnector) |
| insulation_monitoring | DC insulation measurement: Yes |
| overvoltage_category | 2 / 3 (DC / AC) |
| rcmu | — |
| reverse_polarity | DC reverse polarity protection: Yes |
| surge_protection_ac | — |
| surge_protection_dc | — |
Certifications
| standards | ['IEC 62109', 'IEC 62909', 'AS/NZS 4777.2', 'CEI 0-21', 'ABNT BNR 16149 and 16150', 'IEC 62116', 'IEC 61727'] |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | — |
Documents
user-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Digital Operating Instruction 4204260302 — located, not retrieved
rev UNKNOWN
Recorded conflicts
electrical.max_short_circuit_current_per_mppt_a Review required
41.25 / 22 — stored value
[41.25, 22] — Max. short circuit current, module array | 41,25 / 22 A (MPPT1 / MPPT2)
Detected during import v1-freeze-2026-09-batch07
electrical.max_input_current_per_mppt_a Review required
22 / 12 — stored value
[22, 12] — Max. input current (Idc max) | 22 / 12 A - two slash-separated values on one row for the two MPP trackers (MPPT1 / MPPT2); the page also prints 'Number of MPP trackers | 2'
Detected during import v1-freeze-2026-09-batch07
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Backup: Nominal Output Current | 13 A |
| Battery: Max. Input Current | 22 A |
| Dimensions (L×W×H×D) | 165 × 474 × 530 × 165 mm |
| Frequency in Backup Mode | 53 Hz |
| Inverter Design | Transformerless |
| Max. AC Charging Power | 3000 W |
| Max. Grid Power Demand | 3000 VA |
| Max. PV Generator Power | 4.5 kWpeak |
| Max. Switchover Time (Full Backup) | 10 s |
| Max. Switchover Time (PV-Point) | 15 s |
| Max. input current (Idc max) | 22 / 12 A |
| Max. short circuit current, module array | 41,25 / 22 A |
| Overload behaviour | Operating point shift. Power limitation |
| PV input power | 3110 W |
| Usable MPP voltage range | 65 - 530 V |
| Weight incl. Packaging | 19 kg |
| battery.communication | UNKNOWN |
| battery.max_charge_current_a | UNKNOWN |
| battery.max_charge_power_w | 3110 |
| battery.max_discharge_current_a | UNKNOWN |
| battery.max_discharge_power_w | 3110 |
| battery.nominal_battery_voltage_v | UNKNOWN |
| builder_completeness | partial |