GoodWe GW10K-ET Plus
Official manufacturer EU / global EN documentation verified Sept. 2, 2026
UNKNOWN
Identity
| brand | GoodWe |
| category | inverters |
| ean | UNKNOWN |
| generation | ET PLUS+ |
| manufacturer | GoodWe |
| market_version | UNKNOWN |
| model | GW10K-ET Plus |
| mpn | UNKNOWN |
| product_family | ET PLUS+ Series 5-10kW three-phase hybrid (GW5K-ET, GW6.5K-ET, GW8K-ET, GW10K-ET; 16A variants GW5KN-ET, GW6.5KN-ET, GW8KN-ET, GW10KN-ET) |
| product_revision | UNKNOWN |
| product_status | active |
| region | EU / global EN documentation |
| release_year | UNKNOWN |
| sku | GW10K-ET (official datasheet column label; the KB model string 'GW10K-ET Plus' is a series-qualified name, not an official SKU) |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | True |
| battery_support | True |
| battery_type | Li-Ion |
| battery_voltage_class | HV |
| battery_voltage_max_v | 600 |
| battery_voltage_min_v | 180 |
| communication_can | True |
| communication_ethernet | UNKNOWN |
| communication_rs485 | True |
| communication_wifi | True |
| ct_support | UNKNOWN |
| generator_input_support | UNKNOWN |
| grid_certifications | ['AS/NZS 4777.2:2015', 'VDE-AR-N 4105', 'VDE 0126-1-1', 'EN 50549-1', 'G98', 'G99', 'G100', 'CEI 0-21'] |
| grid_export_control | UNKNOWN |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 11 |
| max_battery_charge_current_a | 25 |
| max_battery_charge_power_kw | 10 |
| max_battery_discharge_current_a | 25 |
| max_dc_voltage_v | 1000 |
| max_input_current_per_mppt_a | 12.5 |
| max_pv_input_power_w | 15000 |
| max_short_circuit_current_per_mppt_a | 15.2 |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 850 |
| mppt_min_voltage_v | 200 |
| num_mppt | 2 |
| officially_supported_battery_brands | GoodWe Lynx Home F G2 (LX F6.4-H-20 through LX F25.6-H-20) per Battery Compatibility Overview V029.1, firmware 'ARM25 and DSP09 versions and above' |
| phase_type | three-phase |
| pv_inputs_per_mppt | 1 |
| rated_ac_power_kw | 10 |
| smart_meter_support |
GoodWe GM3000 / GM330 (ET/ET Plus/BT manual, smart-meter RJ45 port section)
Hybrid Inverter ET Series / ET Plus Series 5.0-10.0kW / BT AC-Coupled Inverter User Manual — manual smart-meter connection section, RJ45 meter port (GM3000/GM330)
|
| startup_voltage_v | 180 |
| sunspec_support | UNKNOWN |
| topology | hybrid |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | UNKNOWN |
| depth_mm | 180 |
| enclosure_material | UNKNOWN |
| height_mm | 516 |
| housing_color | UNKNOWN |
| mounting_bolt_size | expansion bolts (size not stated); drill depth 80 mm (manual p.27-31) |
| mounting_hole_diameter_mm | 10 (drill-bit diameter for mounting plate, manual p.27-31: 'The diameter of the drill bit should be 10mm') |
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_type | ['wall'] |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | UNKNOWN |
| torque_specs | UNKNOWN |
| weight_kg | 24 (ET PLUS+ datasheet V2.1) — see data_conflicts, user manual V1.9 p.70 gives 25 |
| width_mm |
415
ET PLUS+ Series 5-10kW | Three Phase Hybrid Inverter datasheet — datasheet general data, 'Dimensions (W×H×D mm) 415 × 516 × 180'
|
Installation
| clearance_bottom_mm | UNKNOWN |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm | UNKNOWN |
| clearance_right_mm | UNKNOWN |
| clearance_top_mm | UNKNOWN |
| direct_sunlight_restriction | UNKNOWN |
| indoor_outdoor | indoor and outdoor (IP66) |
| max_installation_altitude_m | 4000 |
| mounting_orientation |
vertical or at a maximum back tilt of 15 degrees
Hybrid Inverter ET Series / ET Plus Series 5.0-10.0kW / BT AC-Coupled Inverter User Manual — manual p.27-31, 'Install the inverter vertically or at a maximum back tilt of 15 degrees'
|
| orientation_allowed | ['vertical', 'back tilt <= 15 degrees'] |
| orientation_forbidden | ['upside down', 'forward tilt', 'back tilt beyond 15 degrees', 'horizontal'] |
| surface_requirements | UNKNOWN |
Environment
| cooling_method | Natural Convection |
| ik_rating | UNKNOWN |
| ip_rating |
IP66
ET PLUS+ Series 5-10kW | Three Phase Hybrid Inverter datasheet — datasheet general data, 'IP66'
|
| max_altitude_m |
4000
Hybrid Inverter ET Series / ET Plus Series 5.0-10.0kW / BT AC-Coupled Inverter User Manual — manual p.70 technical data, max altitude '4000'
|
| nema_rating | UNKNOWN |
| noise_level_db | UNKNOWN |
| operating_temperature_c |
-35 ~ +60
ET PLUS+ Series 5-10kW | Three Phase Hybrid Inverter datasheet — datasheet general data, 'Operating Temperature -35 ~ +60'
|
| pollution_degree | UNKNOWN |
| relative_humidity | UNKNOWN |
| storage_temperature_c | UNKNOWN |
Interfaces & connectors
| ac_terminal_type |
Feed-Through Terminal Blocks UW10
Hybrid Inverter ET Series / ET Plus Series 5.0-10.0kW / BT AC-Coupled Inverter User Manual — manual p.70, 'Feed-Through Terminal Blocks UW10'
|
| battery_terminal_type | UNKNOWN |
| can | BMS communication via RJ45, CAN or RS485, default CAN, max 5 m cable |
| digital_inputs | pins 3-8 'DRM/DI - DRED or RCR signal controlling ports' (manual p.43-47) |
| dry_contacts | pins 17-18 'DO+/DO- - Load control dry contact' (manual p.43-47) |
| ethernet | optional (WiFi/LAN Kit-20 or Ezlink3000 dongle per GoodWe IoT compatibility list V16) |
| meter_interface | RJ45 smart-meter port (GM3000 / GM330 named in manual) |
| protocol_notes | IoT compatibility list V16 (2026-07-31): ET/ET Plus supports WiFi Kit-20, WIFI/LAN Kit-20 (incl. Cyber Security versions), 4G KIT-EC/KIT-AU/KIT-AF and Ezlink3000, subject to ARM firmware minima; 'ARM 31 or above' noted for power-limitation functions. |
| pv_connector_type |
MC4 (4~6 mm2)
Hybrid Inverter ET Series / ET Plus Series 5.0-10.0kW / BT AC-Coupled Inverter User Manual — manual p.70, 'MC4 (4~6mm2)'
|
| rapid_shutdown_interface | pin 9 'Remote Shutdown - Control the device and stop it once any accident happens' (manual p.43-47) |
| rs485 | RS485 on COM 18-pin terminal block, pins 1-2 '485_A1, 485_B1 - RS485 or EMS' (manual p.43-47) |
| wifi | True |
Controls & display
| display_type | none (LED indicators + app) |
| leds | SYSTEM, BACK-UP, BATTERY, GRID, ENERGY, COM, WiFi, FAULT (manual p.20-21) |
| local_display | False |
| mobile_app | GoodWe SolarGo / SEMS Portal (app referenced in manual) |
| touchscreen | False |
Protection
| afci | UNKNOWN |
| anti_islanding | Anti-islanding Protection - Integrated |
| insulation_monitoring | PV Insulation Resistance Detection - Integrated |
| integrated_dc_switch | UNKNOWN |
| over_current | AC Overcurrent Protection - Integrated |
| over_voltage | AC Overvoltage Protection - Integrated |
| remote_shutdown | Remote Shutdown - Integrated |
| residual_current_monitoring | Residual Current Monitoring - Integrated |
| reverse_polarity | PV Reverse Polarity Protection - Integrated |
| short_circuit | AC Short Circuit Protection - Integrated |
| surge_protection | DC Surge Protection and AC Surge Protection - Integrated |
Certifications
| emc | ['EN61000-6-1', 'EN61000-6-2', 'EN61000-6-3', 'EN61000-6-4', 'EN61000-4-16', 'EN61000-4-18', 'EN61000-4-29'] |
| grid_codes |
['AS/NZS 4777.2:2015', 'VDE-AR-N 4105', 'VDE 0126-1-1', 'EN 50549-1', 'G98', 'G99', 'G100', 'CEI 0-21']
Hybrid Inverter ET Series / ET Plus Series 5.0-10.0kW / BT AC-Coupled Inverter User Manual — manual technical parameters, grid standards row for ET/ET Plus
|
| other | [] |
| regional | [] |
| safety | ['IEC62109-1', 'IEC62109-2'] |
Documents
compatibility-list
GoodWe Battery Compatibility Overview
rev GoodWe Battery Compatibility Overview-20260715-EN-V029.1
datasheet
ET PLUS+ Series 5-10kW | Three Phase Hybrid Inverter datasheet
rev GoodWe-Single page-20230830-EN-V2.1
user-manual
Hybrid Inverter ET Series / ET Plus Series 5.0-10.0kW / BT AC-Coupled Inverter User Manual
rev V1.9-2025-10-14
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_battery
Pylontech US3000C
COMPATIBLEofficially-verified
Pylontech Compatibility List Ver.2.35
GoodWe Lynx Home F G2 Series
COMPATIBLEofficially-verified
GoodWe Lynx-F-G2 Datasheet
BSLBATT B-LFP48-100E (3U Server Rack Battery)
COMPATIBLEmanufacturer-documented
BSLBATT product page
BYD Battery-Box Premium HVS 12.8
COMPATIBLEmanufacturer-documented
BYD Battery-Box Premium HVS&HVM Compatible Inverter List V2.21 (2025-08-20)
BYD Battery-Box Premium HVM 11.0
COMPATIBLEmanufacturer-documented
BYD Battery-Box Premium HVS&HVM Compatible Inverter List V2.21 (2025-08-20)
Pylontech Force H3 (FH10050 module stack)
COMPATIBLEmanufacturer-documented
Compatibility List of Pylontech High Voltage ESS and Inverters Ver.2.40 (2025-08-15)
Pylontech Force H2
COMPATIBLEmanufacturer-documented
Compatibility List of Pylontech High Voltage ESS and Inverters Ver.2.40 (2025-08-15)
GoodWe Lynx Home F Plus+ LX F9.8-H
COMPATIBLEofficially-verified
GoodWe Lynx Home F Plus+ official product page and Lynx Home F Plus+ Series (HV) datasheet V2.1
inverter_meter
GoodWe GM3000
COMPATIBLEofficially-verified
GoodWe ET / ET Plus+ / BT User Manual V1.9-2025-10-14, smart-meter connection section (RJ45 meter port), https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_ET,%20ET%20PLUS+,%20BT_User%20Manual-EN.pdf (fetched 2026-09-02)
inverter_evse
go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)
Recorded conflicts
smart_meter_support Review required
GM3000 / GM330 — ET/ET Plus+/BT user manual V1.9, smart-meter port section
CT90, CT120, GM1000, GMK110 listed for ET/ET Plus (5-10K, 205 ARM) — Compatibility list of GoodWe inverters and IoT products, Version 16 (2026-07-31)
the IoT compatibility list is a dense check-mark grid and the extraction of the ET/ET Plus row may have mis-mapped columns; the manual's named GM3000/GM330 pairing is the more direct statement. Needs cell-precise re-read of the IoT list.
physical.weight_kg Review required
24 — ET PLUS+ datasheet V2.1 2023-08-30, general data
25 — ET/ET Plus+/BT user manual V1.9-2025-10-14, p.70 technical data
document revision difference (2023 datasheet vs 2025 manual) or datasheet rounding; both are official GoodWe documents
model / identity.sku Review required
GW10K-ET Plus — existing ANMA KB record
GW10K-ET (in the ET PLUS+ series) — ET PLUS+ datasheet V2.1 2023-08-30 column header; ET PLUS+ product page model list; ET/ET Plus+/BT user manual V1.9 applicable-models list
GoodWe markets the series as 'ET PLUS+' but the model designations are unchanged from the ET series (GW5K-ET ... GW10K-ET). The 16 A input variants carry an N (GW10KN-ET). 'GW10K-ET Plus' does not appear verbatim in any official document fetched. The KB record's 12.5 A per-MPPT figure matches GW10K-ET (not GW10KN-ET at 16 A).
smart_meter_support Review required
GM3000 / GM330 — ET/ET Plus+/BT user manual V1.9, smart-meter port section
CT90, CT120, GM1000, GMK110 listed for ET/ET Plus (5-10K, 205 ARM) — Compatibility list of GoodWe inverters and IoT products, Version 16 (2026-07-31)
the IoT compatibility list is a dense check-mark grid and the extraction of the ET/ET Plus row may have mis-mapped columns; the manual's named GM3000/GM330 pairing is the more direct statement. Needs cell-precise re-read of the IoT list.
physical.weight_kg Review required
24 — ET PLUS+ datasheet V2.1 2023-08-30, general data
25 — ET/ET Plus+/BT user manual V1.9-2025-10-14, p.70 technical data
document revision difference (2023 datasheet vs 2025 manual) or datasheet rounding; both are official GoodWe documents
model / identity.sku Review required
GW10K-ET Plus — existing ANMA KB record
GW10K-ET (in the ET PLUS+ series) — ET PLUS+ datasheet V2.1 2023-08-30 column header; ET PLUS+ product page model list; ET/ET Plus+/BT user manual V1.9 applicable-models list
GoodWe markets the series as 'ET PLUS+' but the model designations are unchanged from the ET series (GW5K-ET ... GW10K-ET). The 16 A input variants carry an N (GW10KN-ET). 'GW10K-ET Plus' does not appear verbatim in any official document fetched. The KB record's 12.5 A per-MPPT figure matches GW10K-ET (not GW10KN-ET at 16 A).
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| BMS communication cable length | max 5m |
| Back-up Peak Power (VA) | 10000 (16500@60sec) |
| Battery to AC efficiency | 97.50% |
| Nominal Battery Voltage (V) | 500 |
| Nominal Input Voltage (V) | 620 |
| Self-consumption at Night (W) | <15 |