Growatt MIN 3000TL-XH2
Official manufacturer EU verified Sept. 19, 2026
Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Identity
| brand | Growatt |
| category | inverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | XH2 |
| manufacturer | Growatt |
| manufacturer_key | growatt |
| market_version | EU / global EN documentation; single phase 230 V. AU variants take a 600 V PV ceiling per the manual footnote. |
| model | MIN 3000TL-XH2 |
| model_key | min3000tlxh2 |
| mpn | MIN 3000TL-XH2 |
| product_family | MIN |
| product_status | active |
| region | EU |
| release_year | — |
| series | MIN TL-XH2 |
| sku | — |
Electrical
| ac_connection | Single phase (L/N/PE) |
| ac_voltage_range | 160-276V |
| battery_capacity_range_kwh | — |
| battery_communication | — |
| battery_max_charge_current_a | 17 |
| battery_max_charge_power_w | — |
| battery_max_discharge_current_a | 17 |
| battery_max_discharge_power_w | — |
| battery_nominal_battery_voltage_v | 400 |
| battery_type | Cobalt Free LFP |
| battery_voltage_range_v | 360~500V |
| eps_peak_power | — |
| eps_phase | — |
| eps_rated_power_va | — |
| eps_switchover_time_ms | — |
| eps_voltage | — |
| european_efficiency_pct | 97.1 |
| external_transfer_switch_required | — |
| frequency_range_hz | 45-55Hz/55-65Hz |
| inrush_current | <10A/5ms |
| max_ac_active_power_w | 3000 |
| max_ac_current_a | 13.6 |
| max_apparent_power_va | 3000 |
| max_backfeed_current_a | 0 |
| max_dc_input_power_w | 6000 |
| max_dc_voltage_v | 500V |
| max_efficiency_pct | 98.2 |
| max_input_current_per_mppt_a | 16 |
| max_output_fault_current_a | 62A/20us |
| max_short_circuit_current_per_mppt_a | 24 |
| mppt_efficiency_pct | — |
| mppt_voltage_range_v | 40~550V |
| night_self_consumption_w | <3W |
| nominal_ac_voltage | 230V |
| nominal_dc_voltage_v | 360 |
| nominal_frequency_hz | 50/60Hz |
| number_of_mppt | 2 |
| parallel_capability | — |
| phase_count | 1 |
| power_factor_range | 0.8 leading...0.8 lagging |
| rated_ac_power_w | 3000 |
| rated_mppt_voltage_range_v | 95-450V |
| startup_voltage_v | 50 |
| strings_per_mppt | 1 |
| thd_pct | <3% |
Physical / mechanical
| ac_terminal | VPAC06EP-3S(SC)5VPAC06EW-3P(SC)EN032-1128-1001 |
| cooling | Natural convection |
| dc_connector | VP-D4-CHSM0/VP-D4-CHSF0H4 |
| depth_mm | 160 |
| dimensions_mm | 375 x 350 x 160 |
| display | OLED+LED |
| enclosure_material | — |
| height_mm | 350 |
| mounting | — |
| noise_db | <25 dB(A) |
| weight_kg | 10.8 |
| width_mm | 375 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP66 |
| max_altitude_m | 4000 |
| operating_temperature_c | -30 to +60 |
| pollution_degree | 3 outside enclosure / 2 inside enclosure |
| protective_class | — |
| relative_humidity_pct | 0~100% |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | ['RS485', 'USB', 'WiFi (optional)', 'GPRS (optional)', '4G (optional)', 'LAN (optional)', 'RF (optional)'] |
| dry_contact | — |
| meter_interface | — |
| monitoring_portal | — |
| protocols | ['UNKNOWN'] |
Protection
| anti_islanding | Integrated (Active Frequency Drift) |
| arc_fault | — |
| dc_switch | Standard |
| insulation_monitoring | Insulation resistance monitoring: Integrated |
| overvoltage_category | PV:II AC:III BAT:II Others:I |
| rcmu | Residual-current monitoring unit: Integrated |
| reverse_polarity | DC reverse-polarity protection: Integrated |
| surge_protection_ac | Type III |
| surge_protection_dc | Type II |
Certifications
| standards | ['CE', 'IEC 62109', 'AS4777.2', 'CEI 0-21', 'VDE0126-1-1', 'VRF 2019', 'VDE-ARN-4105', 'En50549', 'IEC62116', 'IEC61727', 'G98', 'G99', 'C10/C11', 'UNE217001', 'NTS TypeA', 'UKCA', 'NC rfg', 'Inmetro'] |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | 10 |
Documents
datasheet
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Growatt MIN 2500-6000TL-XH2 datasheet (Growatt Australia) — located, not retrieved
rev UNKNOWN
installation-manual
Growatt MIN 2500-6000TL-XH2 Installation & Operation Manual
rev GR-UM-290-A-01 (PN:044.0108101)
installation-manual
Growatt MIN 2500-6000TL-XH2 Installation & Operation Manual (rev A-02, distributor mirror)
rev GR-UM-290-A-02 (PN:044.0108102)
Recorded conflicts
electrical.mppt_voltage_range_v Review required
40~550V — Installation & Operation Manual GR-UM-290-A-01 (PN:044.0108101)
40-500V — Installation & Operation Manual GR-UM-290-A-02 (PN:044.0108102), distributor mirror
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Battery connector type | VP-D4B-CHSM0B/VP-D4B-CHSF0B |
| DC INPUT QUANTITIES / DC OUTPUT QUANTITIES | Nominal 400V, range 360~500V, 17A continuous, Cobalt Free LFP |
| Lowest operating voltage | 40V |
| Max recommended PV power (module STC) | 6000W |
| Max. output overload protection | 16A |
| Max. recommended PV power(for module STC) | 6000W |
| Min operating voltage | 40V |
| Rated output current | 13A |
| Topology | Non-isolated |
| battery.communication | UNKNOWN |
| battery.max_charge_current_a | 17 |
| battery.max_charge_power_w | UNKNOWN |
| battery.max_discharge_current_a | 17 |
| battery.max_discharge_power_w | UNKNOWN |
| battery.nominal_battery_voltage_v | 400 |
| rejected_document_entry | {"type": "datasheet", "title": "MIN 2500~6000 TL-XH2_Datasheet_202607", "url": "https://en.growatt.com/upload/file/MIN 2500~6000 TL-XH2_Datasheet_202607.pdf", "revision": "202607", "language": "en", "region": "GLOBAL", "publication_date": "2026-07", "is_official": true, "located_not_fetched": true} |
| withheld:pv.mppt_topology_notation | "No. of MPP trackers 2 / No. of PV strings per MPP tracker 1" |