⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Inverters

Hoymiles HYS-4.6LV-EUG1

Official manufacturer EU verified Sept. 22, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category inverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation G1
manufacturer Hoymiles
market_version EU (EUG1 suffix as printed in the model code)
model HYS-4.6LV-EUG1
mpn —
product_family HYS-(3-6)LV-EUG1 Single-phase Hybrid Inverter
product_status active
region EU
release_year —
series HYS-LV-EUG1
sku —

Electrical

ac_connection —
ac_voltage_range 161-276V
battery_capacity_range_kwh —
battery_communication —
battery_max_charge_current_a 100.0
battery_max_charge_power_w —
battery_max_discharge_current_a 100.0
battery_max_discharge_power_w —
battery_nominal_battery_voltage_v —
battery_type —
battery_voltage_range_v 40-60 V
eps_peak_power —
eps_phase —
eps_rated_power_va —
eps_switchover_time_ms —
eps_voltage —
euro_efficiency_pct 97.0
european_efficiency_pct 97.0
external_transfer_switch_required —
frequency_range_hz —
inrush_current —
max_ac_active_power_w —
max_ac_current_a 20.0
max_apparent_power_va 4600
max_backfeed_current_a —
max_battery_discharge_to_ac_efficiency_pct 95.0
max_dc_input_power_w 7500
max_dc_voltage_v 550
max_efficiency_pct 97.6
max_input_current_per_mppt_a 14/14
max_output_fault_current_a —
max_short_circuit_current_per_mppt_a 17
mppt_count 2
mppt_efficiency_pct —
mppt_topology_notation "Number of MPPT 2 / Number of PV strings per MPPT 1"
mppt_voltage_range_max_v 550.0
mppt_voltage_range_min_v 90.0
mppt_voltage_range_v 125-500 V
night_self_consumption_w —
nominal_ac_voltage 230V
nominal_ac_voltage_v 230.0
nominal_dc_voltage_v —
nominal_frequency_hz —
number_of_mppt 2
official_product_url https://www.hoymiles.com/products/hys-lv-eug1-series.html
Hoymiles Hybrid/AC-coupled Inverter User Manual REV2.2 (Global) - covers HYS-3.0/3.6/4.6/5.0/6.0LV-EUG1 and HAS-3.0/3.6/4.6/5.0LV-EUG1
parallel_capability —
phase_count 1
power_factor_range —
product_status active
Hoymiles Hybrid/AC-coupled Inverter User Manual REV2.2 (Global) - covers HYS-3.0/3.6/4.6/5.0/6.0LV-EUG1 and HAS-3.0/3.6/4.6/5.0LV-EUG1
rated_ac_power_w 4600
rated_mppt_voltage_range_v —
startup_voltage_v 150
strings_per_mppt 2
thd_pct —

Physical / mechanical

ac_terminal —
cooling —
dc_connector —
depth_mm —
dimensions_mm —
display —
enclosure_material —
height_mm —
mounting —
noise_db —
weight_kg —
width_mm —

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection IP65
ip_rating IP65
max_altitude_m —
operating_temperature_c -25 to +65 (>45, derating)
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app —
communication [] disputed
dry_contact —
meter_interface —
monitoring_portal —
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Warranty & service

conditions —
extension_options —
standard_years —
warranty_years 10

Documents

datasheet Hoymiles HYS-LV-EUG1 Series Single-Phase Hybrid Inverter Datasheet, REV1.6 rev REV1.6
datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Single-phase Hybrid Inverter Datasheet HYS-(3-6)LV-EUG1 Series — located, not retrieved rev UNKNOWN
installation_manual Hoymiles Hybrid/AC-coupled Inverter User Manual REV2.2 (Global) - covers HYS-3.0/3.6/4.6/5.0/6.0LV-EUG1 and HAS-3.0/3.6/4.6/5.0LV-EUG1
product-page HYS-(3-6)LV-EUG1 Single-phase Hybrid Inverter - Hoymiles product page rev UNKNOWN

Recorded conflicts

strings_per_mppt Review required
2 — value currently stored in ANMA
1 — https://cdn.enfsolar.com/z/pp/2024/11/2x03z31nad78a/hys-lv-eug1-series-datasheet-en-v1-6.pdf
document-revision
max_pv_input_power_w Review required
7500 — value currently stored in ANMA
None — https://cdn.enfsolar.com/z/pp/2024/11/2x03z31nad78a/hys-lv-eug1-series-datasheet-en-v1-6.pdf
document-revision
interfaces.communication Review required
[] — stored value
['RS485', 'optional: Wi-Fi', 'optional: Ethernet', 'optional: 4G'] — incoming package
Detected during import wave8-saturation-2026-09-batch06

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

AC Output (Off-grid) Rated output power (W)4600
Battery voltage range (V)40-60
EPS / backup apparent power9200 VA
Max PV Short-circuit Current (A)17
Max. Input Current (HYS-3.0LV-EUG1 column)14
Recommended max. PV power7500 W
battery.communicationUNKNOWN
battery.max_charge_current_a100.0
battery.max_charge_power_wUNKNOWN
battery.max_discharge_current_a100.0
battery.max_discharge_power_wUNKNOWN
battery.nominal_battery_voltage_vUNKNOWN
withheld:pv.mppt_topology_notation"Number of MPPT 2 / Number of PV strings per MPPT 1"
withheld:pv.strings_per_mppt1