ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Huawei SUN2000-100KTL-M2

Official manufacturer global (a separate 'SUN2000-100KTL-M2 (Chinese mainland)' column exists in the manual with 380 V only) verified Sept. 3, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

brand FusionSolar / SUN2000
category inverters
ean UNKNOWN
generation M2 commercial string inverter, 1100 V DC
hardware_revision UNKNOWN
manufacturer Huawei
manufacturer_legal_entity_as_printed UNKNOWN
market_version UNKNOWN
model SUN2000-100KTL-M2
mpn UNKNOWN
product_family SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) disputed
product_revision UNKNOWN (manual notes BOM-dependent differences: 'The device with the BOM number 01074695-045 does not support MBUS communication'; 'The devices with certain BOM numbers use Staubli MC4 connectors')
product_status active
product_status_evidence No status statement on any fetched Huawei document. https://solar.huawei.com/en/products/sun2000-100ktl-m2/specs/ and .../sun2000-115ktl-m2/specs/ both return HTTP 404 as of 2026-09-03 while sun2000-50ktl-m3/specs/ and SUN2000-150K-MG0/specs/ return 200 — suggestive of withdrawal from the live catalogue, but Huawei prints no status, so this is recorded as evidence, not as a status.
product_type_as_printed Smart PV Controller
region global (a separate 'SUN2000-100KTL-M2 (Chinese mainland)' column exists in the manual with 380 V only)
release_year UNKNOWN
sku UNKNOWN
sku_order_code UNKNOWN
variant_note '-M2' suffix load-bearing: 10-MPPT C&I hardware generation. Not interchangeable with -M3, -M5 or -MG0 units.

Electrical

ac_coupling_support UNKNOWN
backup_eps_output_support false (INFERRED: no backup output documented; commercial grid-tie inverter)
battery_support False
battery_type None (commercial grid-tie string inverter; no storage support mentioned in datasheet)
battery_voltage_class N/A (no battery interface)
battery_voltage_max_v N/A (no battery interface)
battery_voltage_min_v N/A (no battery interface)
communication_can UNKNOWN
communication_ethernet UNKNOWN (Smart Dongle listed as 'Yes' option; interface type not disambiguated in fetched excerpt)
communication_rs485 True
communication_wifi UNKNOWN (Smart Dongle option)
ct_support UNKNOWN
european_efficiency 98.4% @ 400 V, 98.6% @ 480 V
european_efficiency_pct 98.4% (380 V/400 V) / 98.6% (480 V)
generator_input_support UNKNOWN
grid_certifications ['EN 62109-1/-2', 'IEC 62109-1/-2', 'IEC 62116', 'IEC 61727', 'IEC 60068', 'IEC 61683']
grid_export_control UNKNOWN (not captured in fetched datasheet excerpt)
grid_frequency_hz 50/60
grid_voltage_v 380/400/480, 3W+(N)+PE
home_assistant_integration UNKNOWN
max_ac_apparent_power_va 110,000 VA
max_ac_power_kw 110 (labels 'Max. AC Apparent Power 110,000 VA' and max active power '110,000 W' @ cos phi = 1)
max_active_power_w 110,000 W
max_battery_charge_current_a N/A (no battery interface)
max_battery_charge_power_kw N/A (no battery interface)
max_battery_discharge_current_a N/A (no battery interface)
max_dc_voltage_v 1100 disputed
max_efficiency 98.6% @ 400 V, 98.8% @ 480 V
max_efficiency_pct 98.6% (380 V/400 V) / 98.8% (480 V)
max_input_current_per_input_a 20 A
max_input_current_per_mppt_a 30 disputed
SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Technical Specifications (HTML) — 'Max current per MPPT 30 A'
max_output_current_a 160.4 A @400 V, 133.7 A @480 V
max_pv_input_power_w UNKNOWN (neither fetched source states a recommended max PV power for this model)
max_recommended_pv_power_w UNKNOWN
max_short_circuit_current_per_mppt_a 40 disputed
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
mppt_max_voltage_v 1000
mppt_min_voltage_v 200
mppt_voltage_max_v 1,000 V
mppt_voltage_min_v 200 V
night_power_consumption_w < 3.5
SUN2000-100KTL-M2 Smart PV Controller Technical Specification (datasheet PDF asset) — 'Nighttime Power Consumption < 3.5 W'
nighttime_power_consumption < 3.5 W
nominal_frequency 50 Hz / 60 Hz
nominal_output_current_a 144.4 A @400 V, 120.3 A @480 V
nominal_voltage 400 V / 480 V, 3W+(N)+PE (combined 100/115 datasheet); the 100KTL-M2-only datasheet prints "380 V / 400 V / 480 V, 3W+(N)+PE" — see data_conflicts on the 100KTL-M2 record
num_mppt 10
num_pv_inputs 20
officially_supported_battery_brands N/A (no battery support)
oversizing_dc_ac_ratio_guidance UNKNOWN
phase_type three-phase
power_factor_range 0.8 leading ... 0.8 lagging
pv_inputs_per_mppt 2
rated_ac_power_kw 100
rated_ac_power_w 100,000 W
rated_input_voltage_v 600 V @400 Vac, 720 V @480 Vac
region_variant global (400 V and 480 V grid tables; nominal DC input '600 V @ 400 Vac, 720 V @ 480 Vac')
smart_meter_support UNKNOWN (commercial plants typically use SmartLogger-based metering; not verified this session)
sources [{'url': 'https://solar.huawei.com/admin/asset/v1/pro/view/c5056ea20b95424fad3c62f0a5e64a84.pdf', 'title': 'SUN2000-100KTL-M2 Smart PV Controller datasheet (solar.huawei.com asset)', 'doc_type': 'datasheet', 'publisher': 'Huawei', 'revision': 'UNKNOWN (version string not present in fetched excerpt)', 'doc_date': 'UNKNOWN', 'language': 'en', 'region': 'global', 'accessed': '2026-09-01', 'confidence': 'officially-verified'}]
startup_voltage_v 200 disputed
string_rules "Max. input number per MPP tracker: 2" with 10 MPP trackers, i.e. 20 DC inputs maximum. Per-MPPT current 30 A, per-input current 20 A and per-MPPT Isc 40 A are three separate printed limits.
sunspec_support UNKNOWN
thd < 3%
topology grid-tie (commercial string inverter / 'Smart PV Controller'; no battery/storage support in datasheet) disputed
voltage_range UNKNOWN

Physical / mechanical

ac_connector UNKNOWN
cable_entry_positions UNKNOWN
cable_gland_sizes UNKNOWN
cooling Smart Air Cooling
dc_connector Amphenol HH4
depth_mm 365
dimensions_w_h_d_mm 1,035 x 700 x 365 mm
enclosure_material UNKNOWN
height_mm 700
housing_color UNKNOWN
ip_rating IP66
mounting_bolt_size UNKNOWN
mounting_hole_spacing_mm UNKNOWN
mounting_type ['wall', 'support/bracket']
noise_db UNKNOWN
shipping_weight_kg UNKNOWN
torque_specs UNKNOWN
weight_kg <= 93 disputed
SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Technical Specifications (HTML) — General Specifications, 'Net weight <= 93 kg'
width_mm 1035
SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Technical Specifications (HTML) — General Specifications, 'Dimensions (W x H x D) 1035 mm x 700 mm x 365 mm'

Installation

altitude_derating_note manual: '0-5000 m (derated when the altitude is greater than 4000 m)'; datasheet: 'Max Operating Altitude 4,000 m'. See data_conflicts.
clearance_bottom_mm 600-730 recommended ('it is recommended that the clearance from the bottom be between 600 mm and 730 mm')
SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Determining the Installation Position (HTML) — Installation Clearance Requirements, 'it is recommended that the clearance from the bottom be between 600 mm and 730 mm'
clearance_left_mm UNKNOWN (manual Figure 4-3 'Clearance' is a drawing)
clearance_right_mm UNKNOWN (manual Figure 4-3 only)
clearance_top_mm UNKNOWN (manual Figure 4-3 only)
commissioning_app FusionSolar APP (WLAN)
direct_sunlight_restriction advised to install in a sheltered place or install an awning to avoid direct sunlight
electromagnetic_environment_requirement magnetic field strength at the installation position must be less than 4 Gauss
ground_preparation_requirement in areas with abundant vegetation, harden the ground underneath with cement or gravel over an area >= 3 m x 2.5 m
indoor_outdoor outdoor/indoor (IP66); if installed in an enclosed environment, heat-dissipation or ventilation equipment must be installed and the indoor ambient temperature must not exceed the outdoor ambient temperature
max_installation_altitude_m 5000
mounting Mounting plate (weight quoted with mounting plate)
mounting_orientation vertical, or a maximum back tilt of 75 degrees
SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Determining the Installation Position (HTML) — Installation Angle Requirements, 'Install the inverter vertically or at a maximum back tilt of 75 degrees'
noise_separation_requirement_m > 40 m from noise-sensitive areas (residential areas, office areas, schools) unless a low-noise model is used
orientation_allowed ['vertical', 'back tilt up to 75 degrees']
orientation_forbidden ['forward tilted', 'excessive back tilted', 'side tilted', 'horizontal', 'upside down', 'stacked installation (not recommended)']
other_restrictions not in working/living areas; in public places fit a protective net and safety warning sign; not in areas containing flammable materials (sulfur, phosphorus, LPG, marsh gas, flour, cotton), explosives, or corrosive substances (sulfuric/hydrochloric/nitric acid, hydrogen sulfide, chlorine) - corrosion damage is not covered under warranty; salt-affected areas (within 500 m of coast / prone to sea breeze) require consultation with Huawei. SUN2000-75KTL-M1 must be installed in compliance with NBR 16690 and IEC 63226.
surface_requirements mounting structure must be fireproof; not on flammable building materials; installation surface solid enough to bear the inverter weight; not on plaster board walls or similar weak sound-insulating walls in residential areas
ventilation_requirements install in a well-ventilated environment; multiple inverters horizontal mode preferred, triangle mode if space is short; stacked installation not recommended

Environment

cooling_method forced air - 'Smart air cooling'
corrosion_class UNKNOWN
fan_replaceable UNKNOWN
ik_rating UNKNOWN
ip_rating IP66
max_altitude_m 5000 disputed
nema_rating UNKNOWN
noise_level_db UNKNOWN (manual only gives the >40 m separation rule for noise-sensitive areas)
operating_temperature -25 °C ~ 60 °C
operating_temperature_c -25 to +60
pollution_degree UNKNOWN
relative_humidity 0-100% RH disputed
storage_temperature UNKNOWN
storage_temperature_c UNKNOWN

Interfaces & connectors

ac_terminal_type manual: 'OT+waterproof terminal'; datasheet: 'Waterproof Connector + OT/DT Terminal'
can UNKNOWN
cellular UNKNOWN
display LED indicators; FusionSolar APP
dongle_support Smart Dongle-4G (optional)
ethernet UNKNOWN
fe UNKNOWN
local_api_availability UNKNOWN
mbus Monitoring BUS (MBUS): Yes (isolation transformer required)
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
protocol_notes MBUS over the PV cabling is the optimizer/monitoring bus; one BOM (01074695-045) does not support MBUS
pv_connector_type Amphenol Helios H4 (manual note: 'The devices with certain BOM numbers use Staubli MC4 connectors')
SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Technical Specifications (HTML) — General Specifications, 'Input terminal Amphenol Helios H4' + Note [1]
rs485 Supported (MBUS/RS485) disputed
smartlogger_compatibility UNKNOWN
sunspec UNKNOWN
usb Yes (datasheet: 'LED indicators; WLAN adaptor + FusionSolar APP; RS485; USB') disputed
wifi via WLAN adaptor / Smart Dongle
wlan Yes (WLAN + FusionSolar APP)

Controls & display

display_type none (LED indicator only)
leds LED indicator
local_display False
mobile_app FusionSolar App (via USB data cable or WLAN adaptor)

Protection

afci Supported (on SUN2000-100KTL-M2; not offered on 110KTL-M2/115KTL-M2) disputed
anti_islanding Supported disputed
dc_insulation_resistance_detection Yes
dc_reverse_polarity Yes
input_side_disconnection_device Yes
insulation_monitoring Supported (insulation resistance detection)
integrated_dc_switch True
over_current Output overcurrent protection: Supported
overvoltage_category PV II / AC III
protection_class UNKNOWN
pv_string_fault_detection Supported
pv_string_fault_monitoring Yes
rcmu Residual current monitoring unit: Yes
residual_current_monitoring Supported (RCMU)
reverse_polarity Input reverse connection protection: Supported
smart_string_level_disconnector Yes
spd DC Surge Arrester Type II; AC Surge Arrester Type II
surge_protection DC surge protection Type II (Type I optional); AC surge protection Type II. Manual note: 'The SPD complies with IEC/EN 61643-11 and IEC/EN 61643-31.'

Certifications

emc ["IEC 61000-3-12 (manual: 'Equipment complying with IEC 61000-3-12')"]
grid_codes ['IEC 62116', 'IEC 61727'] disputed
other ['IEC 60068', 'IEC 61683', 'IEC/EN 61643-11', 'IEC/EN 61643-31', 'NBR 16690 (75KTL-M1 install standard)', 'IEC 63226 (75KTL-M1 install standard)']
regional ['UNKNOWN']
safety ['EN 62109-1', 'EN 62109-2', 'IEC 62109-1', 'IEC 62109-2'] disputed

Warranty & service

design_life_years UNKNOWN
field_replaceable_parts UNKNOWN
standard_warranty UNKNOWN
standard_years UNKNOWN

Documents

brochure Huawei Commercial & Industrial Smart PV Solution — One-Fits-All Solution (product & compatibility brochure) rev UNKNOWN
datasheet SUN2000-100KTL-M2 / SUN2000-115KTL-M2 Smart PV Controller Datasheet rev UNKNOWN
datasheet SUN2000-100KTL-M2 Smart PV Controller Datasheet rev 20230506
datasheet SUN2000-100KTL-M2 Smart PV Controller Technical Specification (datasheet PDF asset) rev UNKNOWN (no version string in fetched content)
user-manual SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Determining the Installation Position (HTML) rev EDOC1100248746, page Update Date 2026-07-21
user-manual SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) User Manual - Technical Specifications (HTML) rev EDOC1100248746, page Update Date 2026-07-21

Documented compatibility

Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.

inverter_battery

Huawei LUNA2000-5-S0 COMPATIBLEmanufacturer-documented
Huawei LUNA2000-5/10/15-S0 official specs page 'Compatible Inverters' row
Huawei LUNA2000-7-S1 (of the -5/7/10/12/14/15/17/19/21-S1 family) COMPATIBLEmanufacturer-documented
Huawei LUNA2000-5/7/10/12/14/15/17/19/21-S1 official specs page, fetched https://solar.huawei.com/en/products/luna2000-7-14-21-s1/specs/

Recorded conflicts

electrical.nominal_voltage Review required
400 V / 480 V, 3W+(N)+PE — https://solar.huawei.com/-/media/Solar/datasheet/SUN2000100kTL115kTLM2.pdf
380 V/ 400 V/ 480 V, 3W+(N)+PE — https://solar.huawei.com/-/media/SolarV4/solar-version2/common/professionals/all-products/ci/smart-pv-controller/sun2000-100ktl-m2/sun2000-100ktl-m2-datasheet-20230506.pdf
electrical.max_short_circuit_current_per_mppt_a Review required
40 — stored value
40 A — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
electrical.max_input_current_per_mppt_a Review required
30 — stored value
30 A — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
electrical.max_dc_voltage_v Review required
1100 — stored value
1,100 V — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
physical.weight_kg Review required
93 kg — https://solar.huawei.com/-/media/Solar/datasheet/SUN2000100kTL115kTLM2.pdf
≤93 kg — https://solar.huawei.com/-/media/SolarV4/solar-version2/common/professionals/all-products/ci/smart-pv-controller/sun2000-100ktl-m2/sun2000-100ktl-m2-datasheet-20230506.pdf
certifications.grid_codes Review required
['IEC 62116', 'IEC 61727'] — stored value
VDE-AR-N4105, EN 50549-1, EN 50549-2, RD 661, RD 1699, C10/11 — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
certifications.safety Review required
['EN 62109-1', 'EN 62109-2', 'IEC 62109-1', 'IEC 62109-2'] — stored value
EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 61727, IEC 60068, IEC 61683 — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
protection.anti_islanding Review required
Supported — stored value
Yes — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
protection.afci Review required
Supported (on SUN2000-100KTL-M2; not offered on 110KTL-M2/115KTL-M2) — stored value
Arc fault protection: Yes — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
interfaces.usb Review required
Yes (datasheet: 'LED indicators; WLAN adaptor + FusionSolar APP; RS485; USB') — stored value
Yes — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
interfaces.rs485 Review required
Supported (MBUS/RS485) — stored value
Yes — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
environment.relative_humidity Review required
0-100% RH — stored value
0 ~ 100% — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
environment.max_altitude_m Review required
5000 — stored value
4,000 m (13,123 ft.) — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
physical.weight_kg Review required
<= 93 — stored value
93 kg (with mounting plate); the 100KTL-M2-only datasheet prints "≤93 kg" — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
electrical.topology Review required
grid-tie (commercial string inverter / 'Smart PV Controller'; no battery/storage support in datasheet) — stored value
Transformerless — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
electrical.startup_voltage_v Review required
200 — stored value
200 V — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
identity.product_family Review required
SUN2000-(75KTL-M1, 100KTL-M2, 110KTL-M2, 115KTL-M2) — stored value
SUN2000 M2 (Smart PV Controller, C&I string inverter, 10 MPP trackers) — incoming package
Detected during import huawei-fusionsolar-full-portfolio-2026-09-03
max_altitude_m Review required
5000 — User Manual EDOC1100248746 General Specifications (page update 2026-07-21): 'Maximum operating altitude 0-5000 m (derated when the altitude is greater than 4000 m)'
4000 — official datasheet PDF asset 9005a18da2964ba2a0541ce4fbae4bef.pdf: 'Max Operating Altitude 4,000 m (13,123 ft.)'
document revision difference - the manual is substantially newer and raises the ceiling to 5000 m with derating above 4000 m
max_altitude_m Review required
5000 — User Manual EDOC1100248746 General Specifications (page update 2026-07-21): 'Maximum operating altitude 0-5000 m (derated when the altitude is greater than 4000 m)'
4000 — official datasheet PDF asset 9005a18da2964ba2a0541ce4fbae4bef.pdf: 'Max Operating Altitude 4,000 m (13,123 ft.)'
document revision difference - the manual is substantially newer and raises the ceiling to 5000 m with derating above 4000 m

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

BOM-dependent MBUS support'The device with the BOM number 01074695-045 does not support MBUS communication.'
Ground hardening area in vegetated sites>= 3 m x 2.5 m of cement or gravel
Magnetic field strength limit at installation positionless than 4 Gauss
Maximum backfeed current to the PV array0 A
Maximum input current per string20 A
Maximum output current (SUN2000-100KTL-M2)168.8 A (380 V), 160.4 A (400 V), and 133.7 A (480 V)
Minimum distance to noise-sensitive areasgreater than 40 m
Output mode3W + (N) + PE; 'In scenarios without N wires, set Output mode to Three-phase three-wire. In scenarios with N wires, set Output mode to Three-phase four-wire.'
Rated output current (SUN2000-100KTL-M2)152.0 A (380 V), 144.4 A (400 V), and 120.3 A (480 V)
identity.region_as_researchedGlobal / EU / MEA datasheet editions fetched
manufacturer_legal_entity_as_printedUNKNOWN