Huawei SUN2000-10K-LC0
Official manufacturer Regional page: the certificate/grid-code list on the fetched specs page is 'ABNT16149/16150:2013, NRS 097-2-1, PEA, MEA' (Brazil / South Africa / Thailand), with no EU grid codes. Treat this record as the LATAM/APAC/Africa market version; an EU market version was not fetched. verified Sept. 3, 2026
Identity
| category | inverters |
| ean | UNKNOWN |
| generation | LC0 (single-phase 600 V DC platform, 40-560 V MPPT window, THREE MPPTs, IP66) |
| hardware_revision | UNKNOWN |
| legacy_name | UNKNOWN |
| manufacturer | Huawei |
| manufacturer_legal_entity | UNKNOWN |
| market_version | UNKNOWN |
| model | SUN2000-10K-LC0 |
| mpn | UNKNOWN |
| order_code | UNKNOWN |
| product_family | SUN2000-8/10K-LC0 |
| product_status | active |
| product_status_evidence | Live /specs/ page in the solar.huawei.com catalogue at https://solar.huawei.com/en/products/sun2000-8-10k-lc0/specs/ (fetched 2026-09-03). |
| region | Regional page: the certificate/grid-code list on the fetched specs page is 'ABNT16149/16150:2013, NRS 097-2-1, PEA, MEA' (Brazil / South Africa / Thailand), with no EU grid codes. Treat this record as the LATAM/APAC/Africa market version; an EU market version was not fetched. |
| release_year | UNKNOWN |
| sku | UNKNOWN |
| subcategory | single-phase high-power residential hybrid inverter (3 MPPT) |
| variant_note | LC0 drops the 'KTL' token: the model is 'SUN2000-10K-LC0'. It is NOT a bigger LB0: LC0 has THREE MPP trackers (LB0 and L1 have two), a 25 A battery operating current (LB0 16.5 A, L1 15 A) and cooling documented as 'Natural convection / Smart Air Cooling'. It is also NOT a three-phase unit despite its 8-10 kW rating - grid connection is single-phase. |
Electrical
| dc_ac_ratio_guidance | UNKNOWN |
| european_efficiency | 97.5% |
| max_ac_apparent_power_va | 10000 |
| max_active_power_w | UNKNOWN (no separate max active power row on the fetched specs page) |
| max_dc_voltage_v | 600 |
| max_efficiency | 98.1% |
| max_input_current_per_mppt_a | 16 |
| max_output_current_a | 45.5 |
| max_recommended_pv_power_w | 15000 |
| max_short_circuit_current_per_mppt_a | 20 |
| mppt_voltage_max_v | 560 |
| mppt_voltage_min_v | 40 |
| nominal_frequency | 50 Hz / 60 Hz |
| nominal_voltage | 220 V AC / 230 V AC / 240 V AC, L/N + PE, single-phase |
| num_mppt | 3 |
| num_pv_inputs | 3 |
| num_pv_inputs_note | The specs page gives 'Number of MPP trackers 3' and 'Max. number of inputs 3' -> 3 DC inputs total, i.e. one string per MPPT, on a single unit. The page does not print an explicit 'inputs per MPPT' row. |
| oversizing_limits | Recommended max. PV power 15000 Wp against 10000 W rated AC (1.5:1). |
| power_factor_range | 0.8 leading ... 0.8 lagging |
| rated_ac_power_w | 10000 |
| rated_input_voltage_v | 360 |
| rated_output_current_a | UNKNOWN (no 'Rated output current' row on the fetched specs page) |
| startup_voltage_v | 50 |
| string_rules | UNKNOWN |
| thd | <= 3% |
| voltage_range | UNKNOWN |
Physical / mechanical
| cooling | Natural convection / Smart Air Cooling (printed as a combined value) |
| depth_mm | 150 |
| dimensions_note | 'Dimensions (W x H x D) 425 mm x 376.5 mm x 150 mm' for both models; weight differs by model (8K = 14.5 kg, 10K = 15 kg). |
| enclosure_material | UNKNOWN |
| height_mm | 376.5 |
| ip_rating | IP66 |
| mounting_type | UNKNOWN |
| noise_db | UNKNOWN |
| weight_kg | 15.0 |
| width_mm | 425 |
Installation
| ac_connector | UNKNOWN |
| cable_entry | UNKNOWN |
| dc_connector | UNKNOWN |
| dc_switch | UNKNOWN |
| mounting | UNKNOWN |
Environment
| altitude_note | 'Operating altitude 0 - 4000 m (Derated above 2000 m)' |
| max_altitude_m | 4000 |
| operating_temperature | -25 C to +60 C (-13 F to +140 F) |
| relative_humidity | 0% - 100% RH |
Interfaces & connectors
| can | UNKNOWN |
| display | LED indicators |
| dongle_support | Smart Dongle-WLAN-FE (optional) |
| ethernet | Optional, via Smart Dongle-WLAN-FE |
| fe | Optional, via Smart Dongle-WLAN-FE |
| fusionsolar_monitoring | Yes - 'LED indicators; integrated WLAN + FusionSolar app' |
| local_api_availability | UNKNOWN |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| register_doc_availability | UNKNOWN |
| rs485 | True |
| smartlogger_compatibility | UNKNOWN |
| usb | UNKNOWN |
| wlan | Yes, integrated WLAN |
Protection
| ac_overcurrent_protection | Yes |
| ac_overvoltage_protection | Yes |
| ac_short_circuit_protection | Yes |
| afci | Yes - 'Arc fault protection' |
| anti_islanding | Yes |
| dc_reverse_polarity_protection | Yes |
| dc_switch | UNKNOWN |
| insulation_monitoring | Yes |
| over_heat_protection | Yes |
| rcmu | Yes - 'Residual current monitoring unit' |
| surge_protection | DC surge protection: Yes, compatible with TYPE II protection class according to EN/IEC 61643-11; AC surge protection: same |
Certifications
| grid_standards | ['ABNT16149/16150:2013', 'NRS 097-2-1', 'PEA', 'MEA'] |
| note | The grid-connection list on the fetched page contains no EU/UK codes (no G98/G99, no VDE-AR-N-4105, no CEI 0-21). This is a regional catalogue page; do not assume EU grid-code compliance from it. |
| regional_certifications | UNKNOWN |
| safety_standards | ['IEC62109-1', 'IEC62109-2', 'EN 61000-6 series', 'EN 62920 EMC', 'EN 55011 EMC', 'ETSI EN 301-489-1 EMC', 'ETSI EN 301 489-17 EMC', 'EN 61000 3-11', 'EN 61000 3-12', 'IEC61000 2-2'] |
Warranty & service
| extension_options | UNKNOWN |
| note | No warranty row on the fetched specs page. |
| standard_warranty | UNKNOWN |
Documents
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Battery charging from grid | Yes |
| Certificates | EN 62920 EMC, EN 55011 EMC, ETSI EN 301-489-1 EMC, ETSI EN 301 489-17 EMC |
| Cooling | Natural convection / Smart Air Cooling |
| observation:electrical.max_ac_apparent_power_va | {"values": [{"value": "10,000 VA", "source": "SUN2000-8/10K-LC0 specs page, row 'Max. apparent power', 10K column", "source_url": "https://solar.huawei.com/en/products/sun2000-8-10k-lc0/specs/", "confidence": "officially-verified"}], "note": "Single-source anomaly flagged, NOT corrected. The 10K column gives max apparent power equal to rated output power (10,000 VA = 10,000 W, i.e. zero VA headroom) while the 8K column has 8,800 VA against 8,000 W (10% headroom). Only one source was fetchable for this family, so the printed value stands. Note also that the printed 45.5 A max output current corresponds to 10,000 VA at 220 V, the lowest of the three declared nominal voltages - size AC protection for the actual site voltage."} |