ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Huawei SUN2000-15K-MB0

Official manufacturer global verified Sept. 3, 2026

Identity

category inverters
ean UNKNOWN
generation MB0 (three-phase 1100 V DC platform, 200-1000 V MPPT window, two ESS terminals, smart air cooling)
hardware_revision UNKNOWN
legacy_name UNKNOWN
manufacturer Huawei
manufacturer_legal_entity UNKNOWN
market_version UNKNOWN
model SUN2000-15K-MB0
mpn UNKNOWN
order_code UNKNOWN
product_family SUN2000-12/15/17/20/25K-MB0
product_status active
product_status_evidence Listed as a current product in the solar.huawei.com catalogue at https://solar.huawei.com/en/products/sun2000-12-15-17-20-25k-mb0/ with a live /specs/ page (both fetched 2026-09-03).
region global
release_year UNKNOWN
sku UNKNOWN
subcategory three-phase hybrid inverter with two Smart String ESS terminals (Huawei 'Smart Energy Controller')
variant_note MB0 drops the 'KTL' token used by M1/M5: the model is 'SUN2000-20K-MB0', not 'SUN2000-20KTL-MB0'. It shares the M5 chassis and PV front end but adds a two-terminal Smart String ESS interface that M5 does not have.

Electrical

dc_ac_ratio_guidance UNKNOWN
european_efficiency 98.0%
full_power_mppt_voltage_range 410-800 V
max_ac_apparent_power_va 16500
max_active_power_note Specs row 'Max. active power (cos phi = 1)' equals max apparent power numerically for every model.
max_active_power_w 16500
max_dc_voltage_v 1100
max_efficiency 98.4%
max_input_current_per_mppt_a 30 A (two strings) / 20 A (single string) - conditional on how many strings share the MPPT
max_output_current_a 25.2 A / 380 V AC; 23.9 A / 400 V AC; 23.1 A / 415 V AC
max_recommended_pv_power_w 22500
max_short_circuit_current_per_mppt_a 40
mppt_voltage_max_v 1000
mppt_voltage_min_v 200
nominal_frequency 50 Hz / 60 Hz
nominal_voltage 220 V AC / 380 V AC, 230 V AC / 400 Vac, 240 V AC / 415 V AC; 3 W/N + PE (three-phase)
num_mppt 2
num_pv_inputs 4
num_pv_inputs_note 'Number of MPP trackers 2' and 'Max. number of inputs 4' -> 2 MPPTs with up to 2 strings each on a single unit.
oversizing_limits Recommended max. PV power 22500 Wp against 15000 W rated AC.
power_factor_range 0.8 leading ... 0.8 lagging
rated_ac_power_w 15000
rated_input_voltage_v 600
rated_output_current_a 22.8 A / 380 V AC; 21.7 A / 400 V AC; 20.9 A / 415 V AC
startup_voltage_v 200
string_rules Up to 4 PV strings across 2 MPPTs; per-MPPT ceiling depends on string count.
thd <= 3%
voltage_range UNKNOWN

Physical / mechanical

cooling Smart air cooling (fan-assisted)
depth_mm 228
dimensions_note 'Dimensions (W x H x D) 546 mm x 460 mm x 228 mm'; 'Weight 21 kg'.
enclosure_material UNKNOWN
height_mm 460
ip_rating IP66
mounting_type UNKNOWN
noise_db UNKNOWN (the fetched specs page has no noise row)
weight_kg 21.0
width_mm 546

Installation

ac_connector UNKNOWN
cable_entry UNKNOWN
dc_connector UNKNOWN
dc_switch Yes - 'Input-side disconnection device: Yes'
mounting UNKNOWN

Environment

altitude_note 'Max. operating altitude 4000 m (Derated above 2000 m)'
max_altitude_m 4000
operating_temperature -25 C to +60 C
relative_humidity 0% RH - 100% RH

Interfaces & connectors

can UNKNOWN
display LED indicators
dongle_support Smart Dongle-WLAN-FE (optional); Smart Dongle-4G for 4G/3G/2G (optional); SmartAssistant (optional)
ethernet Optional, via Smart Dongle-WLAN-FE
fe Optional, via Smart Dongle-WLAN-FE
fusionsolar_monitoring Yes - 'LED indicators, Integrated WLAN + FusionSolar APP'
local_api_availability UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
register_doc_availability UNKNOWN
rs485 True
smartlogger_compatibility UNKNOWN
usb UNKNOWN
wlan Yes, integrated WLAN

Protection

ac_overcurrent_protection Yes
afci Yes - 'Arc fault protection: Yes'
anti_islanding Yes
dc_reverse_polarity_protection Yes
dc_switch Yes - 'Input-side disconnection device'
insulation_monitoring Yes - 'DC insulation resistance detection: Yes'
overvoltage_category PV II / AC III
rcmu Yes - 'Residual current monitoring unit: Yes'
surge_protection DC surge protection: TYPE II; AC surge protection: Yes, compatible with TYPE II

Certifications

grid_standards ['IEC61727', 'IEC62116', 'IEC61683', 'EN50530', 'ABNT NBR 16149/16150', 'MEA/PEA', 'G99', 'IRR-DCC-MV/IRR-TIC', 'Philippine Grid Code Resolution No. 07', 'NRS 097-2-1', 'EN50549-1', 'VDE4105', 'UTE15-712-1/VFR 2019', 'UNE217002', 'NTS631', 'RD244(UNE217001)', 'PPDS', 'ROGA', 'TOR Erzeuger', 'CEI 0-21:2020-12 V1', 'CEI-016', 'C10/C11', 'EN50549-2', 'VDE4110']
regional_certifications UNKNOWN
safety_standards ['EN/IEC62109-1', 'EN/IEC62109-2']

Warranty & service

extension_options UNKNOWN
note No warranty row. The product page meta description mentions a '25-year engineered service life', which is a design-life claim, not a warranty term.
standard_warranty UNKNOWN

Documents

datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} SUN2000-12/15/17/20/25K-MB0 Smart Energy Controller datasheet (PDF) — located, not retrieved rev Version No.: 02-202403 (per search result title; NOT confirmed by fetch)
datasheet SUN2000-12/15/17/20/25K-MB0 Specs page rev UNKNOWN
datasheet SUN2000-12/15/17/20/25K-MB0 product page rev UNKNOWN

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Engineered service life (product page meta)25-year engineered service life
Full-load MPPT voltage range410-800V
Max. number of paralleled unit (with Smart String ESS)3
Number of terminals (Smart String ESS)2
Overvoltage categoryPV II / AC III

Build a system with this product