⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Inverters

KOSTAL Solar Electric GmbH PLENTICORE G3 17.5

Official manufacturer EU verified Sept. 23, 2026

Identity

category inverters
manufacturer KOSTAL Solar Electric GmbH
model PLENTICORE G3 17.5
region EU

Electrical

backup_max_current_per_phase_a 32.0
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
backup_output True
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
backup_power_per_phase_w 6660
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
backup_rated_power_w 20000
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
battery_supported True
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
battery_voltage_class HV
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
battery_voltage_max_v 820
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
battery_voltage_min_v 95
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
digital_inputs Ripple control receiver or external battery control, CEI, OVP evaluation
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
digital_outputs 4
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
generator_input False
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
grid_frequency_hz 50
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
has_internal_pv_input True
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
max_ac_output_current_a 32.0
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
max_ac_power_w 17500
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
max_charge_current_a 30
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
max_charge_power_w 21000
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
max_discharge_current_a 30
PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
max_input_current_per_mppt_a [30, 30, 30]
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
max_pv_power_wp 26500
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
max_pv_voltage_v 1000
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
max_short_circuit_current_per_mppt_a [42.0, 42.0, 42.0]
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
mppt_voltage_max_v 800
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
mppt_voltage_min_v 198
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
nominal_grid_voltage_v 400
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
number_of_mppt 3
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
number_of_pv_inputs 3
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
phase_count 3
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
rated_ac_current_a 25.3
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
rated_ac_power_w 17500
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
smart_load True
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
startup_voltage_v 95
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
strings_per_mppt_distribution [1, 1, 1]
PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)

Interfaces & connectors

communications ['Ethernet LAN (RJ45) x2', 'Wi-Fi 2.4 GHz (IEEE 802.11 b/g/n)', 'Modbus RTU (energy meter)', 'Integrated webserver']
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
documented_ports [{'port_role': 'MPPT1', 'port_label_from_manual': 'DC1', 'port_type': 'PV string input (push-in spring terminal)', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_current_a': 30, 'max_short_circuit_current_a': 42.0, 'document': 2, 'page': 'Technical data > DC input', 'quote': 'Max. input current (Idc,max) DC1/DC2 input: 17, 17, 17, 17, 17, 17, 30, 30, 30'}, {'port_role': 'MPPT2', 'port_label_from_manual': 'DC2', 'port_type': 'PV string input (push-in spring terminal)', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_current_a': 30, 'max_short_circuit_current_a': 42.0, 'document': 2, 'page': 'Technical data > DC input', 'quote': 'Max. input current (Idc,max) DC1/DC2 input: 17, 17, 17, 17, 17, 17, 30, 30, 30'}, {'port_role': 'MPPT3', 'port_label_from_manual': 'DC3', 'port_type': 'PV string input, switchable to battery input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_current_a': 30, 'max_short_circuit_current_a': 42.0, 'document': 2, 'page': 'Technical data > DC input', 'quote': 'Max. input current (Idc,max) DC3 input: 17, 17, 17, 30, 30, 30, 30, 30, 30'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'DC3 (battery input)', 'port_type': 'High-voltage battery DC input', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 1, 'voltage_min_v': 95, 'voltage_max_v': 820, 'max_current_a': 30, 'document': 1, 'page': 'DC 3 battery input', 'quote': 'Min. Working voltage for battery input (UDCworkbatmin): V 95 / Max. Working voltage for battery input (UDCworkbatmax): V 820 ; Max. charging/discharging current at battery input: S A 17/17 | M A 30/30 | L A 30/30'}, {'port_role': 'GRID', 'port_label_from_manual': 'AC grid connection', 'port_type': '3N~ AC terminal', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': 'Output side (AC)', 'quote': 'Grid connection: 3N~, 230/400V, 50Hz'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'Backup power operation (with KOSTAL BackUp Switch / automatic backup box)', 'port_type': '3N~ AC backup output', 'direction': 'output', 'electrical_domain': 'AC', 'quantity': 1, 'document': 1, 'page': 'Backup operation', 'quote': 'Backup power operation: 3N~, 230/400V, 51Hz ; Max. output current per phase: S A 11.2 | M A 20 | L A 32'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'Ethernet LAN (RJ45)', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 2, 'page': 'Technical data > Interfaces', 'quote': 'Ethernet LAN (RJ45)/Wi-Fi (2.4 GHz [IEEE 802.11 b/g/n]): 2 / yes'}, {'port_role': 'WIFI', 'port_label_from_manual': 'Wi-Fi (2.4 GHz [IEEE 802.11 b/g/n])', 'port_type': 'Wireless', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 2, 'page': 'Technical data > Interfaces', 'quote': 'Ethernet LAN (RJ45)/Wi-Fi (2.4 GHz [IEEE 802.11 b/g/n]): 2 / yes'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital inputs', 'port_type': 'Digital input', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': 'Technical data > Interfaces', 'quote': 'Digital inputs: Ripple control receiver or external battery control, CEI, OVP evaluation'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Digital outputs', 'port_type': 'Switched output 24 V / 100 mA', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 4, 'document': 2, 'page': 'Technical data > Interfaces', 'quote': 'Digital outputs: 4 (24 V, 100 mA)'}, {'port_role': 'METER', 'port_label_from_manual': 'Energy meter connection for collecting energy data (Modbus RTU)', 'port_type': 'Modbus RTU (RS485)', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 2, 'page': 'Technical data > Interfaces', 'quote': 'Energy meter connection for collecting energy data (Modbus RTU): Yes'}]
meter_interface True
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
protocols ['Modbus RTU']
PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)

Documents

datasheet PLENTICORE G3 Technical Specification with battery (DOC03307617, 07/2026)
datasheet PLENTICORE Hybrid inverter - G3 4.0-20 kW Data sheet (DOC03090475, 09/2025)
manual PLENTICORE G3 Hybrid inverter Operating manual - Technical information > Technical data (HTML)
product_page PLENTICORE - Kostal Solar Electric

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

builder_completenesscomplete
region_notesKOSTAL publishes this datasheet for the European market: grid connection is printed as 3N~, 230/400 V, 50 Hz only, and the released-countries list is a separate European document. No other regional specification was found.