Identity

category inverters
manufacturer Must Energy
model PH19-12048 EXP
product_status active
region GLOBAL
variant —

Electrical

ac_frequency_hz 50 / 60 (auto sensing)
ac_input_voltage_range_v 170~280 (UPS) / 90~280 (APL) / 184~253 (VDE)
ac_output_voltage_regulation 230VAC±5% (Setting), battery mode
battery_supported True
charging_algorithm 3-Step (Flooded, AGM / GEL / LEAD), 4-Step (Li)
communication_interfaces USB, RS485, Wi-Fi (remote monitoring)
euro_efficiency_pct 97.0
float_charge_voltage_v 54.8
humidity_range 5% to 95% relative humidity (non-condensing)
max_ac_charge_current_a 150
max_ac_input_voltage_v 300
max_charge_current_a 150
max_dc_voltage_v 600.0
max_efficiency_pct 92
max_input_current_per_mppt_a 27
max_pv_input_power_w 12000
max_pv_voltage_v 500 disputed
MUST PH1900 EXP Series (4~12KW) On/Off Grid Hybrid Solar Inverter
max_short_circuit_current_per_mppt_a 24.0
max_solar_charge_current_a 150
min_battery_voltage_for_pv_charge_v 34
mppt_count 2
mppt_voltage_range_max_v 550.0
mppt_voltage_range_min_v 90.0
mppt_voltage_range_v 90~450 (90~430 for parallel)
nominal_ac_voltage_v 230
nominal_battery_voltage_v 48
nominal_frequency_hz 50.0
number_of_mppt 2
official_product_url https://www.mustpower.com/product/ph1900-exp-series-412kw/
MUST PH1900 EXP Series (4~12KW) On/Off Grid Hybrid Solar Inverter — inventory record source_url
output_waveform Pure Sine Wave
parallel_capability_units 6
peak_efficiency_percent 92
MUST PH1900 EXP Series (4~12KW) On/Off Grid Hybrid Solar Inverter
phase_count 1
MUST PH1900 EXP Series (4~12KW) On/Off Grid Hybrid Solar Inverter
rated_ac_power_w 12000
MUST PH1900 EXP Series (4~12KW) On/Off Grid Hybrid Solar Inverter
startup_voltage_v 100.0
surge_power_w 24000
MUST PH1900 EXP Series (4~12KW) On/Off Grid Hybrid Solar Inverter
transfer_time_ms 10 ms (UPS / VDE4105) / 20 ms (APL)
warranty_years 2

Physical / mechanical

weight_kg 17.6

Environment

ip_rating IP65
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0
operating_temperature_range_c 0~50
storage_temperature_range_c -15~60

Protection

overcharge_protection_voltage_v 60

Certifications

certifications CE

Documents

product_page MUST PH1900 EXP Series (4~12KW) On/Off Grid Hybrid Solar Inverter
specification-page MUST PH1900 EXP Series (6-12kW) - specification table

Recorded conflicts

electrical.max_pv_voltage_v Review required
500 — stored value
500 (450 V for parallel) — incoming package
Detected during import deep-enrich-pass2-2026-09-batch02

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

builder_completenesspartial
region_notesMUST publishes one specification for this series; ANMA's existing Must Energy PH19 records also carry region GLOBAL.