ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Sofar Solar HYD 10KTL-3PH-G4

Verified distributor EU/INT verified Sept. 2, 2026

Identity

brand Sofar Solar
category inverters
ean UNKNOWN
generation G4
manufacturer Sofar Solar
market_version UNKNOWN
model HYD 10KTL-3PH-G4
mpn UNKNOWN
product_family SOFAR HYD 5~10KTL-3PH-G4 (5 / 6 / 8 / 10 kW)
product_revision G4
product_status superseded
product_status_detail superseded (not listed in the SOFAR storage-inverter catalogue on sofarsolar.com as of 2026-09-02; the current three-phase residential hybrid line is HYD-5-20K-LT1)
region EU/INT
release_year 2023
sku UNKNOWN

Electrical

ac_coupling_support UNKNOWN
backup_eps_output_support True
battery_support True
battery_type Li-Ion
battery_voltage_class HV
battery_voltage_max_v 850
battery_voltage_min_v 220
communication_can True
communication_ethernet UNKNOWN
communication_rs485 True
communication_wifi True
ct_support UNKNOWN
generator_input_support UNKNOWN
grid_certifications ['AS/NZS 4777', 'VDE V 0124-100']
grid_export_control UNKNOWN
home_assistant_integration UNKNOWN
max_ac_power_kw 11
max_battery_charge_current_a 24
max_battery_charge_power_kw 11
max_battery_discharge_current_a 24
max_dc_voltage_v 1000
max_input_current_per_mppt_a 25
max_pv_input_power_w 15000
max_short_circuit_current_per_mppt_a UNKNOWN (source repeated same 25A value - likely duplicate/extraction artifact)
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
mppt_max_voltage_v 850
mppt_min_voltage_v 350
num_mppt 2
officially_supported_battery_brands UNKNOWN
phase_type three-phase
pv_inputs_per_mppt 2
rated_ac_power_kw 10
smart_meter_support UNKNOWN
startup_voltage_v 180
sunspec_support UNKNOWN
topology hybrid

Physical / mechanical

bracket_dimensions_mm UNKNOWN
cable_entry_positions UNKNOWN
cable_gland_sizes UNKNOWN
depth_mm 205
dimension_note 'Dimensions (W*H*D) 530*460*205mm' - official G4 datasheet
enclosure_material UNKNOWN
height_mm 460
housing_color UNKNOWN
mounting_bolt_size UNKNOWN
mounting_hole_diameter_mm UNKNOWN
mounting_hole_spacing_mm UNKNOWN
mounting_plate_dimensions_mm UNKNOWN
mounting_type ['wall']
screw_sizes UNKNOWN
shipping_weight_kg UNKNOWN
terminal_locations UNKNOWN
torque_specs UNKNOWN
weight_kg 25
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Weight 25kg'
width_mm 530
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Dimensions (W*H*D) 530*460*205mm'

Installation

altitude_derating_note 'Max. operating altitude 4000m (derating above 2000m)'
clearance_bottom_mm UNKNOWN
clearance_front_mm UNKNOWN
clearance_left_mm UNKNOWN
clearance_right_mm UNKNOWN
clearance_top_mm UNKNOWN
indoor_outdoor indoor and outdoor (IP66)
max_installation_altitude_m 4000
mounting_orientation wall mounted ('Installation method Wall Mounted' - G4 datasheet); tilt/clearance rules UNKNOWN - the G4 user manual could not be fetched this session
surface_requirements UNKNOWN

Environment

cooling_method natural convection ('Cooling mode Natural')
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Cooling mode Natural'
corrosion_class UNKNOWN
fan_replaceable n/a (natural cooling)
ik_rating UNKNOWN
ip_rating IP66
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Degree of protection IP66'
max_altitude_m 4000
nema_rating UNKNOWN
noise_level_db UNKNOWN (row ABSENT from the G4 datasheet)
operating_temperature_c -30 to +60 (derating above +45)
pollution_degree UNKNOWN
relative_humidity 5% to 95%
storage_temperature_c UNKNOWN

Interfaces & connectors

ac_terminal_type UNKNOWN (row ABSENT from the G4 datasheet)
backup_eps_terminal yes - backup AC output 3(N)~+PE 380/400/415 Vac, 10000 W
battery_terminal_type UNKNOWN
bluetooth UNKNOWN
bms_communication CAN/RS485 ('BMS communication CAN/RS485')
can yes
cellular optional 4G
cloud_api SOFAR Cloud / SOFAR Monitor (brand platform; not named in the datasheet row)
ethernet optional LAN
generator_terminal UNKNOWN
local_api UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
protocol_notes 'Communication CAN/RS485/WiFi, Optional: 4G/LAN' - official G4 datasheet
pv_connector_type UNKNOWN (row ABSENT from the G4 datasheet)
rs485 yes
sunspec UNKNOWN
usb UNKNOWN
wifi yes (built-in per 'Communication: CAN/RS485/WiFi')
zigbee UNKNOWN

Controls & display

audible_alarm UNKNOWN
buttons UNKNOWN
display_type LCD
leds UNKNOWN
local_display True
mobile_app yes ('Display LCD & APP'); app name not printed on the datasheet
touchscreen UNKNOWN
web_interface UNKNOWN

Protection

afci yes
anti_islanding yes - anti-island protection
insulation_monitoring yes - insulation impedance detection
integrated_dc_switch True
over_current yes - output overcurrent protection
over_temperature UNKNOWN
over_voltage yes - output overvoltage protection
overvoltage_category UNKNOWN
protection_class UNKNOWN
residual_current_monitoring yes - residual current detection
reverse_polarity yes - PV reverse connection protection and battery reverse connection protection
short_circuit yes - output short circuit protection
surge_protection PV: Type II, AC: Type II
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — Protection, 'Surge protection PV: Type II, AC: Type II'

Certifications

emc ['IEC/EN 61000-6-1', 'IEC/EN 61000-6-3']
grid_codes ['EN 50549-1', 'VDE-AR-N 4105', 'VDE V 0124', 'CEI 0-21']
other []
regional []
safety ['IEC/EN 62109-1', 'IEC/EN 62109-2']

Warranty & service

conditions UNKNOWN
design_life_years UNKNOWN
extended_options_years UNKNOWN
field_replaceable_parts UNKNOWN
service_intervals UNKNOWN
standard_years UNKNOWN (row ABSENT from the official G4 datasheet; the older non-G4 datasheet states 'Standard 5 years')

Documents

datasheet THREE-PHASE ENERGY STORAGE INTEGRATED INVERTER HYD 5K~20KTL-3PH (datasheet, NON-G4 product) rev 10KTL-3PH-A* 03 / 2023--V2
datasheet THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) rev DV20230060101 (marked DRAFT)
product-page SOFAR storage-inverter product catalogue (current line-up) rev UNKNOWN

Documented compatibility

Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.

inverter_battery

Pylontech US3000C COMPATIBLEofficially-verified
Pylontech Compatibility List Ver.2.35
BSLBATT B-LFP48-100E (3U Server Rack Battery) COMPATIBLEmanufacturer-documented
BSLBATT product page
Pytes V5 / V5-alpha (printed as V5° / V5°α) COMPATIBLEmanufacturer-documented
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Pytes E-Box 48100R COMPATIBLEmanufacturer-documented
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)

inverter_evse

go-e GmbH go-eCharger Gemini (11kW and 22kW variants) COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)

Recorded conflicts

environment.ip_rating and environment.cooling_method Review required
IP65, forced airflow, noise <45dB — existing record / non-G4 datasheets
IP66, natural cooling, noise row ABSENT — official G4 datasheet
G4 vs non-G4
physical dimensions and weight Review required
565*508*244 mm, 37 kg — existing record source (mysolar.ee non-G4 mirror)
586.6*515*261.2 mm, 37 kg — official 2023 non-G4 datasheet
530*460*205 mm, 25 kg — official G4 datasheet
the G4 is a physically smaller, lighter, naturally cooled chassis
max_battery_charge_current_a / max_battery_discharge_current_a Review required
24 — existing record (mysolar.ee non-G4 mirror)
30 — official G4 datasheet: 'Max. charge/discharge current 30A/30A'
50 (25A/25A across two channels) — official 2023 non-G4 datasheet
G4 vs non-G4 plus revision change
battery_voltage_min_v / battery_voltage_max_v Review required
220-850 — existing record (mysolar.ee non-G4 mirror)
180-600 — official G4 datasheet: 'Voltage range 180~600V'
180-800 — official 2023 non-G4 datasheet: '180V~800V'
G4 vs non-G4 plus non-G4 revision change; a safety-critical divergence
max_short_circuit_current_per_mppt_a Review required
UNKNOWN (existing record) — existing record
23 — official G4 datasheet: 'Max. short-circuit current 23A'
15 — official 2023 non-G4 datasheet: '15A'
G4 vs non-G4
max_input_current_per_mppt_a Review required
25 — existing record (mysolar.ee non-G4 mirror)
18 — official G4 datasheet: 'Max. input current per MPPT 18A'
14.5 — official 2023 non-G4 datasheet: 'Max. Input Current/MPPT 14.5A'
three different documents for two different products plus a revision change
mppt_min_voltage_v / mppt_max_voltage_v Review required
350-850 — existing record (mysolar.ee non-G4 mirror, 2020 revision)
180-960 — official G4 datasheet: 'MPPT operating range 180~960V' (the official 2023 non-G4 datasheet also gives 180~960V)
G4 vs non-G4, and a document-revision change within the non-G4 family between 2020 and 2023
max_dc_voltage_v Review required
1000 — existing record (non-G4 mirror); official non-G4 datasheet also gives 1000V
1100 — official G4 datasheet: 'Max. input voltage 1100V'
G4 vs non-G4 product
RECORD-LEVEL SOURCING Review required
record's stored electrical values — mysolar.ee mirror of 'Technical-Data-SOFAR-SOLAR-HYD-10KTL-3PH.pdf', doc code 'HYD 10K/15K/20KTL-3PH_EN V2 _202003_' - i.e. the NON-G4 HYD 10K/15K/20KTL-3PH family
official G4 datasheet values — https://www1.sofarsolar.com/upload/file/20230614/1686728831168009063.pdf, doc DV20230060101, 'HYD 5~10KTL-3PH-G4'
The record is named 'HYD 10KTL-3PH-G4' but every stored electrical/physical value traces to the older, electrically different NON-G4 HYD 10K/15K/20KTL-3PH. The G4 is a different chassis and a different power stage. The whole record needs re-sourcing against the G4 datasheet.
environment.ip_rating and environment.cooling_method Review required
IP65, forced airflow, noise <45dB — existing record / non-G4 datasheets
IP66, natural cooling, noise row ABSENT — official G4 datasheet
G4 vs non-G4
physical dimensions and weight Review required
565*508*244 mm, 37 kg — existing record source (mysolar.ee non-G4 mirror)
586.6*515*261.2 mm, 37 kg — official 2023 non-G4 datasheet
530*460*205 mm, 25 kg — official G4 datasheet
the G4 is a physically smaller, lighter, naturally cooled chassis
max_battery_charge_current_a / max_battery_discharge_current_a Review required
24 — existing record (mysolar.ee non-G4 mirror)
30 — official G4 datasheet: 'Max. charge/discharge current 30A/30A'
50 (25A/25A across two channels) — official 2023 non-G4 datasheet
G4 vs non-G4 plus revision change
battery_voltage_min_v / battery_voltage_max_v Review required
220-850 — existing record (mysolar.ee non-G4 mirror)
180-600 — official G4 datasheet: 'Voltage range 180~600V'
180-800 — official 2023 non-G4 datasheet: '180V~800V'
G4 vs non-G4 plus non-G4 revision change; a safety-critical divergence
max_short_circuit_current_per_mppt_a Review required
UNKNOWN (existing record) — existing record
23 — official G4 datasheet: 'Max. short-circuit current 23A'
15 — official 2023 non-G4 datasheet: '15A'
G4 vs non-G4
max_input_current_per_mppt_a Review required
25 — existing record (mysolar.ee non-G4 mirror)
18 — official G4 datasheet: 'Max. input current per MPPT 18A'
14.5 — official 2023 non-G4 datasheet: 'Max. Input Current/MPPT 14.5A'
three different documents for two different products plus a revision change
max_dc_voltage_v Review required
1000 — existing record (non-G4 mirror); official non-G4 datasheet also gives 1000V
1100 — official G4 datasheet: 'Max. input voltage 1100V'
G4 vs non-G4 product
mppt_min_voltage_v / mppt_max_voltage_v Review required
350-850 — existing record (mysolar.ee non-G4 mirror, 2020 revision)
180-960 — official G4 datasheet: 'MPPT operating range 180~960V' (the official 2023 non-G4 datasheet also gives 180~960V)
G4 vs non-G4, and a document-revision change within the non-G4 family between 2020 and 2023
RECORD-LEVEL SOURCING Review required
record's stored electrical values — mysolar.ee mirror of 'Technical-Data-SOFAR-SOLAR-HYD-10KTL-3PH.pdf', doc code 'HYD 10K/15K/20KTL-3PH_EN V2 _202003_' - i.e. the NON-G4 HYD 10K/15K/20KTL-3PH family
official G4 datasheet values — https://www1.sofarsolar.com/upload/file/20230614/1686728831168009063.pdf, doc DV20230060101, 'HYD 5~10KTL-3PH-G4'
The record is named 'HYD 10KTL-3PH-G4' but every stored electrical/physical value traces to the older, electrically different NON-G4 HYD 10K/15K/20KTL-3PH. The G4 is a different chassis and a different power stage. The whole record needs re-sourcing against the G4 datasheet.

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Battery charge/discharge efficiency97.2%
Max. current from grid27.8A@415Vac / 29.0A@400Vac / 30.3A@380Vac
Max. strings per MPPT1
Peak apparent power (60s)20000VA, 60s
Standby self-consumption<20W
Switching time (grid to backup)20ms
TopologyNon-Isolation
identity.product_statussuperseded (not listed in the SOFAR storage-inverter catalogue on sofarsolar.com as of 2026-09-02; the current three-phase residential hybrid line is HYD-5-20K-LT1)