Sofar Solar HYD 10KTL-3PH-G4
Verified distributor EU/INT verified Sept. 2, 2026
Identity
| brand | Sofar Solar |
| category | inverters |
| ean | UNKNOWN |
| generation | G4 |
| manufacturer | Sofar Solar |
| market_version | UNKNOWN |
| model | HYD 10KTL-3PH-G4 |
| mpn | UNKNOWN |
| product_family | SOFAR HYD 5~10KTL-3PH-G4 (5 / 6 / 8 / 10 kW) |
| product_revision | G4 |
| product_status | superseded |
| product_status_detail | superseded (not listed in the SOFAR storage-inverter catalogue on sofarsolar.com as of 2026-09-02; the current three-phase residential hybrid line is HYD-5-20K-LT1) |
| region | EU/INT |
| release_year | 2023 |
| sku | UNKNOWN |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | True |
| battery_support | True |
| battery_type | Li-Ion |
| battery_voltage_class | HV |
| battery_voltage_max_v | 850 |
| battery_voltage_min_v | 220 |
| communication_can | True |
| communication_ethernet | UNKNOWN |
| communication_rs485 | True |
| communication_wifi | True |
| ct_support | UNKNOWN |
| generator_input_support | UNKNOWN |
| grid_certifications | ['AS/NZS 4777', 'VDE V 0124-100'] |
| grid_export_control | UNKNOWN |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 11 |
| max_battery_charge_current_a | 24 |
| max_battery_charge_power_kw | 11 |
| max_battery_discharge_current_a | 24 |
| max_dc_voltage_v | 1000 |
| max_input_current_per_mppt_a | 25 |
| max_pv_input_power_w | 15000 |
| max_short_circuit_current_per_mppt_a | UNKNOWN (source repeated same 25A value - likely duplicate/extraction artifact) |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 850 |
| mppt_min_voltage_v | 350 |
| num_mppt | 2 |
| officially_supported_battery_brands | UNKNOWN |
| phase_type | three-phase |
| pv_inputs_per_mppt | 2 |
| rated_ac_power_kw | 10 |
| smart_meter_support | UNKNOWN |
| startup_voltage_v | 180 |
| sunspec_support | UNKNOWN |
| topology | hybrid |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | UNKNOWN |
| depth_mm | 205 |
| dimension_note | 'Dimensions (W*H*D) 530*460*205mm' - official G4 datasheet |
| enclosure_material | UNKNOWN |
| height_mm | 460 |
| housing_color | UNKNOWN |
| mounting_bolt_size | UNKNOWN |
| mounting_hole_diameter_mm | UNKNOWN |
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_plate_dimensions_mm | UNKNOWN |
| mounting_type | ['wall'] |
| screw_sizes | UNKNOWN |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | UNKNOWN |
| torque_specs | UNKNOWN |
| weight_kg |
25
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Weight 25kg'
|
| width_mm |
530
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Dimensions (W*H*D) 530*460*205mm'
|
Installation
| altitude_derating_note | 'Max. operating altitude 4000m (derating above 2000m)' |
| clearance_bottom_mm | UNKNOWN |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm | UNKNOWN |
| clearance_right_mm | UNKNOWN |
| clearance_top_mm | UNKNOWN |
| indoor_outdoor | indoor and outdoor (IP66) |
| max_installation_altitude_m | 4000 |
| mounting_orientation | wall mounted ('Installation method Wall Mounted' - G4 datasheet); tilt/clearance rules UNKNOWN - the G4 user manual could not be fetched this session |
| surface_requirements | UNKNOWN |
Environment
| cooling_method |
natural convection ('Cooling mode Natural')
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Cooling mode Natural'
|
| corrosion_class | UNKNOWN |
| fan_replaceable | n/a (natural cooling) |
| ik_rating | UNKNOWN |
| ip_rating |
IP66
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — General Parameters, 'Degree of protection IP66'
|
| max_altitude_m | 4000 |
| nema_rating | UNKNOWN |
| noise_level_db | UNKNOWN (row ABSENT from the G4 datasheet) |
| operating_temperature_c | -30 to +60 (derating above +45) |
| pollution_degree | UNKNOWN |
| relative_humidity | 5% to 95% |
| storage_temperature_c | UNKNOWN |
Interfaces & connectors
| ac_terminal_type | UNKNOWN (row ABSENT from the G4 datasheet) |
| backup_eps_terminal | yes - backup AC output 3(N)~+PE 380/400/415 Vac, 10000 W |
| battery_terminal_type | UNKNOWN |
| bluetooth | UNKNOWN |
| bms_communication | CAN/RS485 ('BMS communication CAN/RS485') |
| can | yes |
| cellular | optional 4G |
| cloud_api | SOFAR Cloud / SOFAR Monitor (brand platform; not named in the datasheet row) |
| ethernet | optional LAN |
| generator_terminal | UNKNOWN |
| local_api | UNKNOWN |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| protocol_notes | 'Communication CAN/RS485/WiFi, Optional: 4G/LAN' - official G4 datasheet |
| pv_connector_type | UNKNOWN (row ABSENT from the G4 datasheet) |
| rs485 | yes |
| sunspec | UNKNOWN |
| usb | UNKNOWN |
| wifi | yes (built-in per 'Communication: CAN/RS485/WiFi') |
| zigbee | UNKNOWN |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | UNKNOWN |
| display_type | LCD |
| leds | UNKNOWN |
| local_display | True |
| mobile_app | yes ('Display LCD & APP'); app name not printed on the datasheet |
| touchscreen | UNKNOWN |
| web_interface | UNKNOWN |
Protection
| afci | yes |
| anti_islanding | yes - anti-island protection |
| insulation_monitoring | yes - insulation impedance detection |
| integrated_dc_switch | True |
| over_current | yes - output overcurrent protection |
| over_temperature | UNKNOWN |
| over_voltage | yes - output overvoltage protection |
| overvoltage_category | UNKNOWN |
| protection_class | UNKNOWN |
| residual_current_monitoring | yes - residual current detection |
| reverse_polarity | yes - PV reverse connection protection and battery reverse connection protection |
| short_circuit | yes - output short circuit protection |
| surge_protection |
PV: Type II, AC: Type II
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet) — Protection, 'Surge protection PV: Type II, AC: Type II'
|
Certifications
| emc | ['IEC/EN 61000-6-1', 'IEC/EN 61000-6-3'] |
| grid_codes | ['EN 50549-1', 'VDE-AR-N 4105', 'VDE V 0124', 'CEI 0-21'] |
| other | [] |
| regional | [] |
| safety | ['IEC/EN 62109-1', 'IEC/EN 62109-2'] |
Warranty & service
| conditions | UNKNOWN |
| design_life_years | UNKNOWN |
| extended_options_years | UNKNOWN |
| field_replaceable_parts | UNKNOWN |
| service_intervals | UNKNOWN |
| standard_years | UNKNOWN (row ABSENT from the official G4 datasheet; the older non-G4 datasheet states 'Standard 5 years') |
Documents
datasheet
THREE-PHASE ENERGY STORAGE INTEGRATED INVERTER HYD 5K~20KTL-3PH (datasheet, NON-G4 product)
rev 10KTL-3PH-A* 03 / 2023--V2
datasheet
THREE-PHASE HYBRID INVERTER SOFAR HYD 5~10KTL-3PH-G4 5 / 6 / 8 / 10 kW (datasheet)
rev DV20230060101 (marked DRAFT)
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_battery
Pylontech US3000C
COMPATIBLEofficially-verified
Pylontech Compatibility List Ver.2.35
BSLBATT B-LFP48-100E (3U Server Rack Battery)
COMPATIBLEmanufacturer-documented
BSLBATT product page
Pytes V5 / V5-alpha (printed as V5° / V5°α)
COMPATIBLEmanufacturer-documented
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Pytes E-Box 48100R
COMPATIBLEmanufacturer-documented
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
inverter_evse
go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)
Recorded conflicts
environment.ip_rating and environment.cooling_method Review required
IP65, forced airflow, noise <45dB — existing record / non-G4 datasheets
IP66, natural cooling, noise row ABSENT — official G4 datasheet
G4 vs non-G4
physical dimensions and weight Review required
565*508*244 mm, 37 kg — existing record source (mysolar.ee non-G4 mirror)
586.6*515*261.2 mm, 37 kg — official 2023 non-G4 datasheet
530*460*205 mm, 25 kg — official G4 datasheet
the G4 is a physically smaller, lighter, naturally cooled chassis
max_battery_charge_current_a / max_battery_discharge_current_a Review required
24 — existing record (mysolar.ee non-G4 mirror)
30 — official G4 datasheet: 'Max. charge/discharge current 30A/30A'
50 (25A/25A across two channels) — official 2023 non-G4 datasheet
G4 vs non-G4 plus revision change
battery_voltage_min_v / battery_voltage_max_v Review required
220-850 — existing record (mysolar.ee non-G4 mirror)
180-600 — official G4 datasheet: 'Voltage range 180~600V'
180-800 — official 2023 non-G4 datasheet: '180V~800V'
G4 vs non-G4 plus non-G4 revision change; a safety-critical divergence
max_short_circuit_current_per_mppt_a Review required
UNKNOWN (existing record) — existing record
23 — official G4 datasheet: 'Max. short-circuit current 23A'
15 — official 2023 non-G4 datasheet: '15A'
G4 vs non-G4
max_input_current_per_mppt_a Review required
25 — existing record (mysolar.ee non-G4 mirror)
18 — official G4 datasheet: 'Max. input current per MPPT 18A'
14.5 — official 2023 non-G4 datasheet: 'Max. Input Current/MPPT 14.5A'
three different documents for two different products plus a revision change
mppt_min_voltage_v / mppt_max_voltage_v Review required
350-850 — existing record (mysolar.ee non-G4 mirror, 2020 revision)
180-960 — official G4 datasheet: 'MPPT operating range 180~960V' (the official 2023 non-G4 datasheet also gives 180~960V)
G4 vs non-G4, and a document-revision change within the non-G4 family between 2020 and 2023
max_dc_voltage_v Review required
1000 — existing record (non-G4 mirror); official non-G4 datasheet also gives 1000V
1100 — official G4 datasheet: 'Max. input voltage 1100V'
G4 vs non-G4 product
RECORD-LEVEL SOURCING Review required
record's stored electrical values — mysolar.ee mirror of 'Technical-Data-SOFAR-SOLAR-HYD-10KTL-3PH.pdf', doc code 'HYD 10K/15K/20KTL-3PH_EN V2 _202003_' - i.e. the NON-G4 HYD 10K/15K/20KTL-3PH family
official G4 datasheet values — https://www1.sofarsolar.com/upload/file/20230614/1686728831168009063.pdf, doc DV20230060101, 'HYD 5~10KTL-3PH-G4'
The record is named 'HYD 10KTL-3PH-G4' but every stored electrical/physical value traces to the older, electrically different NON-G4 HYD 10K/15K/20KTL-3PH. The G4 is a different chassis and a different power stage. The whole record needs re-sourcing against the G4 datasheet.
environment.ip_rating and environment.cooling_method Review required
IP65, forced airflow, noise <45dB — existing record / non-G4 datasheets
IP66, natural cooling, noise row ABSENT — official G4 datasheet
G4 vs non-G4
physical dimensions and weight Review required
565*508*244 mm, 37 kg — existing record source (mysolar.ee non-G4 mirror)
586.6*515*261.2 mm, 37 kg — official 2023 non-G4 datasheet
530*460*205 mm, 25 kg — official G4 datasheet
the G4 is a physically smaller, lighter, naturally cooled chassis
max_battery_charge_current_a / max_battery_discharge_current_a Review required
24 — existing record (mysolar.ee non-G4 mirror)
30 — official G4 datasheet: 'Max. charge/discharge current 30A/30A'
50 (25A/25A across two channels) — official 2023 non-G4 datasheet
G4 vs non-G4 plus revision change
battery_voltage_min_v / battery_voltage_max_v Review required
220-850 — existing record (mysolar.ee non-G4 mirror)
180-600 — official G4 datasheet: 'Voltage range 180~600V'
180-800 — official 2023 non-G4 datasheet: '180V~800V'
G4 vs non-G4 plus non-G4 revision change; a safety-critical divergence
max_short_circuit_current_per_mppt_a Review required
UNKNOWN (existing record) — existing record
23 — official G4 datasheet: 'Max. short-circuit current 23A'
15 — official 2023 non-G4 datasheet: '15A'
G4 vs non-G4
max_input_current_per_mppt_a Review required
25 — existing record (mysolar.ee non-G4 mirror)
18 — official G4 datasheet: 'Max. input current per MPPT 18A'
14.5 — official 2023 non-G4 datasheet: 'Max. Input Current/MPPT 14.5A'
three different documents for two different products plus a revision change
max_dc_voltage_v Review required
1000 — existing record (non-G4 mirror); official non-G4 datasheet also gives 1000V
1100 — official G4 datasheet: 'Max. input voltage 1100V'
G4 vs non-G4 product
mppt_min_voltage_v / mppt_max_voltage_v Review required
350-850 — existing record (mysolar.ee non-G4 mirror, 2020 revision)
180-960 — official G4 datasheet: 'MPPT operating range 180~960V' (the official 2023 non-G4 datasheet also gives 180~960V)
G4 vs non-G4, and a document-revision change within the non-G4 family between 2020 and 2023
RECORD-LEVEL SOURCING Review required
record's stored electrical values — mysolar.ee mirror of 'Technical-Data-SOFAR-SOLAR-HYD-10KTL-3PH.pdf', doc code 'HYD 10K/15K/20KTL-3PH_EN V2 _202003_' - i.e. the NON-G4 HYD 10K/15K/20KTL-3PH family
official G4 datasheet values — https://www1.sofarsolar.com/upload/file/20230614/1686728831168009063.pdf, doc DV20230060101, 'HYD 5~10KTL-3PH-G4'
The record is named 'HYD 10KTL-3PH-G4' but every stored electrical/physical value traces to the older, electrically different NON-G4 HYD 10K/15K/20KTL-3PH. The G4 is a different chassis and a different power stage. The whole record needs re-sourcing against the G4 datasheet.
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Battery charge/discharge efficiency | 97.2% |
| Max. current from grid | 27.8A@415Vac / 29.0A@400Vac / 30.3A@380Vac |
| Max. strings per MPPT | 1 |
| Peak apparent power (60s) | 20000VA, 60s |
| Standby self-consumption | <20W |
| Switching time (grid to backup) | 20ms |
| Topology | Non-Isolation |
| identity.product_status | superseded (not listed in the SOFAR storage-inverter catalogue on sofarsolar.com as of 2026-09-02; the current three-phase residential hybrid line is HYD-5-20K-LT1) |