SolarEdge SE10K-RWS (StorEdge Three Phase Inverter)
Official manufacturer EU / RoW verified Sept. 1, 2026
SolarEdge residential PV inverters page, 'SolarEdge Home Hub Inverters' family tile. NOTE: this is the Home Hub family photo, used here because SolarEdge no longer publishes a product page for the older StorEdge RWS range; it is the same chassis family but NOT a verified SE10K-RWS photo.
Identity
| brand | SolarEdge |
| category | inverters |
| ean | UNKNOWN |
| generation | SetApp generation (no LCD; commissioned with the SetApp mobile application) |
| manufacturer | SolarEdge Technologies |
| market_version | 380/220 or 400/230 Vac three phase |
| model | SE10K-RWS (StorEdge Three Phase Inverter) |
| mpn | SE10K-RWS (region suffix varies) |
| product_family | StorEdge Three Phase Inverter (RWS) |
| product_revision | UNKNOWN |
| product_status | UNKNOWN |
| product_status_detail | UNKNOWN (largely superseded in the EU by the SolarEdge Home Hub three-phase range, e.g. the SE10K-RWB48 already in this dataset) |
| region | EU / RoW |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | False |
| battery_support | True |
| battery_type | 48 V DC-coupled battery: 'Multiple LG Chem, BYD, and SolarEdge options listed' in the datasheet's supported-battery row (exact model list not transcribed verbatim) |
| battery_voltage_class | LV |
| battery_voltage_max_v | 62 |
| battery_voltage_min_v |
40
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — INPUT BATTERY 'Input Voltage Range: 40-62 Vdc'
|
| communication_can | False |
| communication_ethernet | True |
| communication_rs485 | True |
| communication_wifi | True |
| ct_support | Via the SolarEdge Energy Meter with CTs |
| generator_input_support | False |
| grid_certifications | ['VDE 0126-1-1', 'VDE-AR-N-4105', 'G98', 'G99'] |
| grid_export_control | UNKNOWN (export limitation is a SolarEdge platform feature; not printed as a row in the fetched extraction) |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 10 |
| max_battery_charge_current_a |
130
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — INPUT BATTERY 'Maximum Continuous Input Current: 130 Adc'
|
| max_battery_charge_power_kw |
5
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — INPUT BATTERY 'Maximum DC Power: 5000 W'
|
| max_battery_discharge_current_a | 130 |
| max_dc_voltage_v |
900
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — 'Maximum Input Voltage: 900 Vdc'
|
| max_input_current_per_mppt_a | 16.5 |
| max_pv_input_power_w |
13500
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — 'Maximum DC Power (Module STC): 13500 W'
|
| max_short_circuit_current_per_mppt_a | UNKNOWN |
| modbus_rtu | Yes - SunSpec Modbus RTU over RS485 |
| modbus_tcp | Yes - SunSpec Modbus TCP over the LAN port; disabled by default, enabled via SetApp (Site Communication > Modbus TCP), default port 1502 on SetApp inverters |
| mppt_max_voltage_v | N/A - 900 Vdc is the absolute maximum input voltage, not an MPPT ceiling |
| mppt_min_voltage_v | N/A - fixed 750 Vdc nominal string voltage, not an MPPT window |
| num_mppt | 1 fixed-voltage DC bus - NOT a conventional MPPT. MPPT is performed per module by the mandatory SolarEdge Power Optimizers; the inverter holds its DC input at a FIXED 750 Vdc nominal. |
| officially_supported_battery_brands | ['LG Chem', 'BYD', 'SolarEdge'] |
| phase_type | three-phase |
| pv_inputs_per_mppt | 2 x MC4 pair (two physical DC input pairs feeding one fixed-voltage bus) |
| rated_ac_power_kw |
10
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — 'Rated AC Power Output: 10000 VA' (SE10K-RWS column)
|
| smart_meter_support | Yes - SolarEdge Energy Meter on RS485 (2 x RS485 ports) |
| startup_voltage_v | UNKNOWN |
| sunspec_support | Yes - 'All SolarEdge inverters with SetApp configuration are SunSpec-supported' |
| topology | hybrid: three-phase grid-tie inverter with an integrated DC-coupled 48 V battery port, in a MANDATORY per-module power-optimizer architecture. Distinct from the SE10K-RWB48 Home Hub already in this dataset (that is the backup-capable Home Hub generation). |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | AC output cable diameter 15 - 21 mm |
| depth_mm | 193 |
| diameter_mm | N/A |
| din_rail_type | N/A |
| enclosure_material | UNKNOWN |
| height_mm |
853
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — 'Dimensions (H x W x D): 853 x 316 x 193 mm'
|
| housing_color | UNKNOWN |
| mounting_bolt_size | UNKNOWN |
| mounting_hole_diameter_mm | UNKNOWN |
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_plate_dimensions_mm | UNKNOWN |
| mounting_type | ['wall'] |
| rack_units | N/A |
| screw_sizes | UNKNOWN |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | 2 x MC4 pair for DC; AC terminal block behind a gland; separate battery terminals |
| torque_specs | UNKNOWN (the SE10K-RWS installation guide was not fetched) |
| weight_kg |
37
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — 'Weight: 37 kg'
|
| width_mm | 316 |
Installation
| altitude_derating_note | UNKNOWN |
| clearance_bottom_mm | UNKNOWN |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm | UNKNOWN |
| clearance_right_mm | UNKNOWN |
| clearance_top_mm | UNKNOWN |
| cooling_airflow_requirements | UNKNOWN |
| direct_sunlight_restriction | UNKNOWN |
| indoor_outdoor | indoor and outdoor (IP65) |
| installation_humidity_range | UNKNOWN |
| installation_temperature_range_c | UNKNOWN |
| max_installation_altitude_m | UNKNOWN |
| minimum_wall_thickness_mm | UNKNOWN |
| mounting_orientation | UNKNOWN (wall mounting; installation guide not fetched) |
| orientation_allowed | ['vertical (wall)'] |
| orientation_forbidden | ['UNKNOWN'] |
| surface_requirements | UNKNOWN |
| two_person_lift_required | UNKNOWN (37 kg - practically yes, but not stated in the fetched sources) |
| ventilation_requirements | UNKNOWN - the unit uses internal and external fans |
Environment
| cooling_method | forced air - internal and external fans |
| corrosion_class | UNKNOWN |
| fan_replaceable | UNKNOWN |
| ik_rating | UNKNOWN |
| ip_rating |
IP65 - outdoor and indoor
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — 'Protection Rating: IP65 - outdoor and indoor'
|
| max_altitude_m | UNKNOWN |
| nema_rating | UNKNOWN |
| noise_level_db | < 50 dBA |
| operating_temperature_c | -40 to +60 |
| pollution_degree | UNKNOWN |
| relative_humidity | UNKNOWN |
| salt_mist_resistance | UNKNOWN |
| storage_temperature_c | UNKNOWN |
| uv_resistance | UNKNOWN |
Interfaces & connectors
| ac_terminal_type | Screw terminal block behind a gland; AC output cable diameter 15-21 mm |
| analog_inputs | UNKNOWN |
| auxiliary_power_output | UNKNOWN |
| backup_eps_terminal | N/A (no backup output on the RWS StorEdge three-phase; backup is a Home Hub RWB feature) |
| battery_terminal_type | UNKNOWN (48 V DC battery terminals; installation guide not fetched) |
| bluetooth | UNKNOWN |
| can | UNKNOWN (the battery link on StorEdge products is a dedicated battery communication cable; type not printed in the fetched extraction) |
| cellular | Built-in cellular (optional) |
| cloud_api | SolarEdge Monitoring Platform |
| digital_inputs | UNKNOWN |
| dry_contacts | UNKNOWN |
| ethernet | Yes |
| generator_start_contact | N/A |
| generator_terminal | N/A |
| local_api | SunSpec Modbus TCP on the LAN |
| modbus_rtu | Yes, SunSpec Modbus RTU over RS485 |
| modbus_tcp |
Yes, SunSpec Modbus TCP over Ethernet; disabled by default, port 1502 on SetApp inverters
SunSpec Implementation Technical Note — SunSpec technical note v3.2: 'All SolarEdge inverters with SetApp configuration are SunSpec-supported'; default TCP port 1502; disabled by default
|
| mqtt | UNKNOWN |
| ocpp | N/A |
| programmable_relay | UNKNOWN |
| protocol_notes | Datasheet row transcribed verbatim: 'Supported Communication Interfaces: 2 x RS485, Ethernet, ZigBee communications for Smart Energy, Wi-Fi, Built-in cellular (optional)'. The SunSpec/Modbus capability is documented in SolarEdge's SunSpec technical note, not in this datasheet. |
| pv_connector_type | MC4 - 2 x MC4 pair |
| rapid_shutdown_interface | Inherent to the optimizer architecture (SafeDC); no separate row in this datasheet |
| relay_outputs | UNKNOWN |
| rs232 | UNKNOWN |
| rs485 | Yes - 2 x RS485 |
| smart_load_output | Via ZigBee Smart Energy products |
| sunspec | Yes |
| usb | UNKNOWN |
| wifi | Yes |
| zigbee | Yes - 'ZigBee communications for Smart Energy' |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | ON/OFF/P switch |
| display_type | none - SetApp generation |
| leds | 3 LEDs (SolarEdge SetApp convention: blue = communicating, green = producing, red = error) |
| local_display | False |
| mobile_app | SolarEdge SetApp (commissioning); mySolarEdge / SolarEdge Monitoring (owner) |
| remote_display_option | UNKNOWN |
| status_indicators | LEDs plus SetApp |
| touchscreen | False |
| web_interface | SolarEdge Monitoring Platform |
Protection
| afci | UNKNOWN |
| anti_islanding | Yes - 'Utility Monitoring, Islanding Protection, Country Configurable Thresholds: Yes' |
| ground_fault_protection | Ground fault isolation detection, 700 kOhm sensitivity |
| insulation_monitoring | Ground fault isolation detection, 700 kOhm sensitivity |
| integrated_breakers_fuses | UNKNOWN |
| integrated_dc_switch | UNKNOWN (SolarEdge inverters are generally certified as DC disconnection devices per IEC 60947-3; not confirmed for this model in the fetched documents) |
| over_current | UNKNOWN |
| over_temperature | UNKNOWN |
| over_voltage | UNKNOWN |
| overvoltage_category | UNKNOWN |
| protection_class | UNKNOWN |
| residual_current_monitoring | UNKNOWN |
| reverse_polarity | UNKNOWN |
| short_circuit | UNKNOWN |
| surge_protection | UNKNOWN |
| under_voltage | UNKNOWN |
Certifications
| emc | ['IEC61000-6-2', 'IEC61000-6-3', 'IEC61000-3-11', 'IEC61000-3-12'] |
| grid_codes | ['VDE 0126-1-1', 'VDE-AR-N-4105', 'G98', 'G99'] |
| other | [] |
| regional | ['RoHS: Yes'] |
| safety | ['IEC-62109'] |
Warranty & service
| conditions | Datasheet banner: '12 YEAR WARRANTY'. Extensions sold separately (SolarEdge warranty-extension price lists located but not fetched). |
| cycle_life | N/A |
| design_life_years | UNKNOWN |
| extended_options_years | [20, 25] |
| fan_replaceable | UNKNOWN |
| field_replaceable_parts | ['UNKNOWN'] |
| fuse_replaceable | UNKNOWN |
| service_intervals | UNKNOWN |
| standard_years |
12
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet — datasheet banner '12 YEAR WARRANTY'
|
Packaging & logistics
| gross_weight_kg | UNKNOWN |
| package_depth_mm | UNKNOWN |
| package_height_mm | UNKNOWN |
| package_width_mm | UNKNOWN |
| transport_restrictions | UNKNOWN |
| units_per_pallet | UNKNOWN |
Documents
datasheet
StorEdge Three Phase Inverter SE5K-RWS / SE7K-RWS / SE8K-RWS / SE10K-RWS Datasheet
rev UNKNOWN
quick-start
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
StorEdge SE10K-RWS Quick Manual (ManualsLib mirror) — located, not retrieved
rev UNKNOWN
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| AC Output Voltage - Line to Line / Line to Neutral (Nominal) | 380/220 ; 400/230 Vac |
| AC Output Voltage - Line to Neutral Range | 184 - 264.5 Vac |
| AC output conduit/cable size | 15 - 21 mm |
| Ground Fault Isolation Detection | 700 kOhm Sensitivity |
| Maximum Continuous Output Current (per Phase) | 16 A |
| Maximum Inverter Efficiency / European Weighted Efficiency | 98 % / 97.6 % |
| Nominal DC Input Voltage | 750 Vdc |
| Peak Battery to Grid discharge Efficiency | 96.1 % |
| identity.product_status | UNKNOWN (largely superseded in the EU by the SolarEdge Home Hub three-phase range, e.g. the SE10K-RWB48 already in this dataset) |