⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Inverters

SolaX Power X1-HYBRID-3.7-D

Official manufacturer GLOBAL verified Sept. 22, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category inverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation G4
manufacturer SolaX Power
market_version EU / global single-phase edition; the product page prints rated AC voltage 1/N/PE, 220/230/240 V
model X1-HYBRID-3.7-D
mpn —
product_family X1-Hybrid
product_status active
region GLOBAL
release_year —
series X1-Hybrid G4
sku —

Electrical

ac_connection —
ac_voltage_range —
battery_capacity_range_kwh —
battery_chemistry_documented Lithium / Lead-acid
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
battery_communication —
battery_max_charge_current_a 13
battery_max_charge_power_w —
battery_max_discharge_current_a —
battery_max_discharge_power_w —
battery_nominal_battery_voltage_v —
battery_supported True
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
battery_type Li-ion / Lead-acid
battery_voltage_max_v 480
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
battery_voltage_min_v 80
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
battery_voltage_range_v —
eps_peak_power 6000 VA, 10 s
eps_phase single-phase (1 / N / PE)
eps_rated_power_va 3680
eps_switchover_time_ms < 10 ms
eps_voltage —
euro_efficiency_pct 97.0
european_efficiency_pct —
external_transfer_switch_required —
frequency_range_hz —
inrush_current —
max_ac_active_power_w —
max_ac_apparent_power_va 3680
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
max_ac_current_a 16.0
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
max_apparent_power_va —
max_backfeed_current_a —
max_charge_current_a 30
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
max_dc_input_power_w 7400
max_dc_voltage_v —
max_discharge_current_a 30
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
max_efficiency_pct —
max_input_current_per_mppt_a 16 A / 16 A disputed
max_output_fault_current_a —
max_pv_input_voltage_v 600
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
max_recommended_pv_array_power_kwp 7.4
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
max_short_circuit_current_per_mppt_a —
mppt_count 2
mppt_efficiency_pct —
mppt_voltage_max_v 550
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
mppt_voltage_min_v 70
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
mppt_voltage_range_v 70 ~ 550 V
night_self_consumption_w —
nominal_ac_voltage 1 / N / PE, 220 / 230 / 240 V
nominal_ac_voltage_v 230.0
nominal_dc_voltage_v —
nominal_frequency_hz —
nominal_grid_voltage_v 230
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
number_of_mppt 2
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
number_of_pv_inputs 2
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
parallel_capability —
phase_count 1
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
power_factor_range —
rated_ac_power_w 3680
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
rated_input_voltage_v 360
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
rated_mppt_voltage_range_v —
startup_voltage_v 90
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
strings_per_mppt 2 (1/1)
strings_per_mppt_distribution [1, 1]
SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
thd_pct —
transfer_time_ms 20.0

Physical / mechanical

ac_terminal —
cooling —
dc_connector —
depth_mm 181
dimensions_mm 482 x 417 x 181
display —
enclosure_material —
height_mm 417
mounting —
noise_db —
weight_kg 25
width_mm 482

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection IP65
ip_rating IP65
max_altitude_m —
operating_temperature_c -35 to +60 (derating above +45)
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app —
communication []
dry_contact —
meter_interface SolaX authorized DDSU666 and DDSU666-CT (series user manual)
monitoring_portal —
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Warranty & service

conditions —
extension_options —
standard_years —
warranty_years 10

Documents

datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} SolaX X1-HYBRID G4 Datasheet EN (V3.0, 20250427) — located, not retrieved rev UNKNOWN
datasheet SolaX X1-HYBRID G4 Datasheet EN V2.9.1 (650.00009.00)
datasheet X1 HYBRID G4 Datasheet - ES (Spanish edition) rev V2.4 (document code 650.00009.00)
datasheet X1-HYBRID G4 Datasheet - PT (Portuguese edition) rev V2.4
product-page SolaX X1 HYBRID G4 product page rev UNKNOWN
user-manual X1-Hybrid G4 series user manual (EN) rev Version 3.0

Recorded conflicts

electrical.max_input_current_per_mppt_a Review required
16 A / 16 A — stored value
[16, 16] — Max. input current per MPPT (MPPT1/2) | 16 A / 16 A
Detected during import v1-freeze-2026-09-batch10

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Comunicaciones (ES datasheet V2.4)CT/Medidor (opcional), Control externo RS485, Wifi de bolsillo (opcional: LAN/4G de bolsillo), DRM, actualizacion USB, NTC (opcional)
Consumo interno (por la noche) (ES datasheet V2.4)<17W en espera, <2,7W en ralenti
Corriente max. de cortocircuito (FV1/FV2) [A] (ES datasheet V2.4)20/20
Corriente maxima continua de carga/descarga [A] (ES datasheet V2.4)13 / 21,7 / 26,1 / 32,6 across the 3.0 / 3.7 / 6.0 / 7.5 columns
Eficiencia maxima [%] / Eficiencia Euro [%] (ES datasheet V2.4)97,6 / 97,0
Manual validity list (series user manual V3.0)X1-Hybrid-3.0-D/M; X1-Hybrid-3.7-D/M; X1-Hybrid-5.0-D/M, X1-Hybrid-5.0K-D; X1-Hybrid-6.0-D/M; X1-Hybrid-7.5-D/M
Normas de seguridad / EMC / codigos de red (ES datasheet V2.4)EN/IEC62109-1/-2; EN61000-6-1/2/3/4; EN61000-3-2/3/11/12; VDE4105, G99, G98, AS4777, EN50549, CEI 0-21, IEC61727, RD1699, NRS 097-2-1, PEA/MEA, VFR2019, C10/11
Potencia max. aparente de salida de CA [VA] (ES datasheet V2.4)4500 / 5500 / 9000 / 10000 across the 3.0 / 3.7 / 6.0 / 7.5 columns
Potencia max. del conjunto FV [Wp] (ES datasheet V2.4), X1-HYBRID-3.7-D column9200 Wp
Temperatura de almacenamiento / Altitud maxima / Humedad relativa (ES datasheet V2.4)-40~+65 C / <3000 m / 0~100 %
Tension max. de entrada FV [V] (ES datasheet V2.4)600
battery.communicationUNKNOWN
battery.max_charge_current_aUNKNOWN
battery.max_charge_power_wUNKNOWN
battery.max_discharge_current_aUNKNOWN
battery.max_discharge_power_wUNKNOWN
battery.nominal_battery_voltage_vUNKNOWN
documented_relationship:inverter_battery{"to_manufacturer": "SolaX Power", "to_model": "T-BAT H 5.8 (with HV11550 / HV10230 modules)", "relationship_type": "inverter_battery", "match_level": "series", "status": "compatible", "source": "X1-Hybrid G4 series user manual (EN) Version 3.0, 2024-08-08, section 8.5 Battery Power Cable Connection", "source_url": "https://www.solaxpower.com/uploads/file/solax-320101081103-x1-hybrid-g4-series-user-manual-en.pdf", "source_page": "Section 8.5", "confidence": "officially-verified", "required_accessories": "UNKNOWN", "required_firmware": "UNKNOWN", "region": "EU/global", "notes": "Printed verbatim in the manual's battery power cable connection section as a supported battery for this inverter series. Series-level, not a per-rating approval. ANMA stores 'Triple Power T-BAT-SYS-HV 5.8 (T58)'; the manual's spelling differs and no document I read equates the two, so the endpoint is left as the m
identity.region_as_printedEU/global