Solinteg M2HT-29.9K-80
Official manufacturer GLOBAL verified Sept. 25, 2026
Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Identity
| category | inverters |
| manufacturer | Solinteg |
| model | M2HT-29.9K-80 |
| product_status | active |
| region | GLOBAL |
| variant | — |
Electrical
| ac_voltage_options_v |
['220/380', '230/400', '240/415']
SOLINTEG Integ M M2HT 10-30kW product page
|
| ac_voltage_v |
3L/N/PE; 220/380V; 230/400V; 240/415V
SOLINTEG Integ M M2HT 10-30kW product page
|
| battery_charge_discharge_current_printed |
40*2/40*2
SOLINTEG Integ M M2HT 10-30kW product page
|
| battery_voltage_max_v |
850
SOLINTEG Integ M M2HT 10-30kW product page
|
| battery_voltage_min_v |
130
SOLINTEG Integ M M2HT 10-30kW product page
|
| euro_efficiency_pct | 98.2 |
| max_ac_current_a |
47.6
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_ac_output_current_a |
47.6
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_charge_current_a |
[40, 40]
disputed
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_discharge_current_a |
80
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_efficiency_pct | 98.6 |
| max_input_current_per_mppt_a | 26.0 |
| max_pv_current_per_mppt_a |
[20, 20, 20, 20]
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_pv_input_current_a |
[20, 20, 20, 20]
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_pv_power_kwp |
60
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_pv_power_w |
60000
SOLINTEG Integ M M2HT 10-30kW product page
|
| max_short_circuit_current_per_mppt_a | 39.0 |
| mppt_count | 2 |
| mppt_voltage_max_v |
950
SOLINTEG Integ M M2HT 10-30kW product page
|
| mppt_voltage_min_v |
120
SOLINTEG Integ M M2HT 10-30kW product page
|
| nominal_ac_voltage_v |
400
SOLINTEG Integ M M2HT 10-30kW product page
|
| nominal_frequency_hz | 50.0 |
| number_of_mppt |
4
SOLINTEG Integ M M2HT 10-30kW product page
|
| official_product_url |
https://www.solinteg.com/integ-m/2087826891295506432
SOLINTEG Integ M M2HT 10-30kW product page — inventory record source_url
|
| peak_backup_apparent_power_kva |
50 @10s
disputed
SOLINTEG Integ M M2HT 10-30kW product page
|
| peak_backup_duration_s |
10
SOLINTEG Integ M M2HT 10-30kW product page
|
| phase_count |
3
SOLINTEG Integ M M2HT 10-30kW product page
|
| rated_ac_power_kw |
29.9
SOLINTEG Integ M M2HT 10-30kW product page
|
| rated_ac_power_w |
29900
SOLINTEG Integ M M2HT 10-30kW product page
|
Environment
| ip_rating | IP65 |
| operating_temperature_max_c | 60.0 |
| operating_temperature_min_c | -25.0 |
Warranty & service
| warranty_years | 10 |
Documents
product_page
SOLINTEG Integ M M2HT 10-30kW product page
Recorded conflicts
electrical.max_charge_current_a Review required
[40, 40] — stored value
80 — Max. Charge/Discharge Current [A] | 40*2/40*2
Detected during import deep-enrich-2026-09-batch21
electrical.peak_backup_apparent_power_kva Review required
50 @10s — stored value
50 — Peak Output Apparent Power [kVA](Back-up Side) | 50@10s
Detected during import deep-enrich-2026-09-batch21
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| builder_completeness | partial |
| region_notes | 3L/N/PE 220/380V, 230/400V, 240/415V IEC product. |