Sungrow SG10RS
Official manufacturer AU verified Sept. 3, 2026
Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
product page hero image
Identity
| brand | Sungrow |
| category | inverters |
| ean | UNKNOWN |
| generation | RS string inverter disputed |
| grid_type | TN / TT |
| hardware_revision | UNKNOWN |
| legacy_name | UNKNOWN |
| manufacturer | Sungrow |
| manufacturer_legal_entity | Sungrow Power Supply Co., Ltd. |
| market_version | AU (AS/NZS 4777.2:2020) disputed |
| model | SG10RS |
| mpn | UNKNOWN |
| order_code | UNKNOWN |
| phase_configuration | single-phase (1 / N / PE) |
| product_family | SG5.0RS-ADA / SG8.0RS / SG9.0RS / SG10RS disputed |
| product_status | active |
| product_status_detail | not listed on the official 2026 sungrowpower.com string-inverter index (which shows only SG3.0/3.6/4.0RS and SG5.0/6.0RS for 1-phase on the global site); the family remains current in AU and LATAM. Status recorded as regionally-scoped rather than globally-active. |
| product_status_evidence | official global product index fetched 2026-09-03 |
| region | AU |
| release_year | UNKNOWN |
| sku | UNKNOWN |
| subcategory | grid-tied PV string inverter (single-phase, no battery interface) |
| topology | transformerless (no galvanic isolation) |
| variant_note | Family also includes SG5.0RS-ADA (AU arc-detection variant) and the Brazilian '-L' variants SG8.0RS-L / SG9.0RS-L / SG10RS-L, which are separate records and were not researched here. ENRICHMENT TARGET: ANMA already holds an SG10RS record built from the AU V14 datasheet. This record is the GLOBAL (GL V12) variant and is electrically different (see data_conflicts). |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | false (INFERRED: grid-tie string inverter, no backup output in datasheet) |
| battery_support | False |
| battery_type | None (grid-tie string inverter; no battery support in datasheet V14) |
| battery_voltage_class | N/A (no battery interface) |
| battery_voltage_max_v | N/A (no battery interface) |
| battery_voltage_min_v | N/A (no battery interface) |
| communication_can | UNKNOWN |
| communication_ethernet | True |
| communication_rs485 | True |
| communication_wifi | True |
| ct_support | UNKNOWN |
| dc_ac_ratio | 1.5 |
| european_efficiency_pct | 97.4 |
| feed_in_phases | 1 / 1 |
| generator_input_support | N/A (grid-tie) |
| grid_certifications | ['IEC 62109-1/2', 'AS/NZS 4777.2:2020'] |
| grid_export_control | UNKNOWN (DI for 'Ripple control & DRM' listed; export-limit meter not captured in fetched excerpt) |
| grid_frequency_hz | 50/60 |
| grid_frequency_range | 45 Hz - 55 Hz (50 Hz) / 55 Hz - 65 Hz (60 Hz) |
| grid_voltage_v |
220/230/240
SG5.0RS-ADA/SG8.0/10RS Datasheet — 'Rated grid voltage 220 V / 230 V / 240 V'; 'Grid voltage range 154 V - 276 V'
|
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 9.999 (label 'Max apparent power 9999 VA') |
| max_ac_power_w | 10000 |
| max_apparent_power_va | 10000 |
| max_battery_charge_current_a | N/A (no battery interface) |
| max_battery_charge_power_kw | N/A (no battery interface) |
| max_battery_discharge_current_a | N/A (no battery interface) |
| max_dc_short_circuit_current_total_a | 60 |
| max_dc_voltage_v | 600 |
| max_efficiency_pct | 97.8 |
| max_input_current_per_input_a | 16 |
| max_input_current_per_mppt_a | 20 (label 'Max. PV input current 60 A (20 A / 20 A / 20 A)') disputed |
| max_input_current_total_a | 48 |
| max_output_current_a | 45.5 |
| max_pv_input_power_w | 12000 (label 'Recommended max. PV input power 12 kWp') |
| max_short_circuit_current_per_mppt_a | 30 (fetched excerpt showed single figure 'Max DC short-circuit current 30 A'; per-MPPT vs total breakdown not captured) disputed |
| min_operating_voltage_v | 40 |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 560 |
| mppt_min_voltage_v | 40 |
| mppt_voltage_max_v | 560 |
| mppt_voltage_min_v | 40 |
| mppt_voltage_range_for_nominal_power | UNKNOWN |
| night_power_consumption | UNKNOWN |
| nominal_dc_voltage_v | 360 |
| nominal_frequency | 50 Hz / 60 Hz |
| nominal_voltage | 220 V / 230 V / 240 V (1 / N / PE) |
| num_mppt | 3 |
| num_pv_inputs | 3 |
| officially_supported_battery_brands | N/A (no battery support) |
| oversizing_guidance | recommended max PV input power 15.0 kWp vs 10000 W rated AC (1.5x) |
| phase_type | single-phase |
| power_factor_range | > 0.99 default; 0.8 leading - 0.8 lagging |
| pv_inputs_per_mppt | 1 |
| rated_ac_power_kw | 9.999 (label 'Rated output power 9999 W' - AU single-phase limit design) |
| rated_ac_power_w | 10000 |
| rated_output_current_a | 43.5 |
| recommended_pv_power_w | 15000 |
| region_variant | AU (datasheet V14 EN(AU); 'SG5.0RS-ADA' sibling is the arc-detection AU 5 kW variant) |
| smart_meter_support | UNKNOWN |
| sources | [{'url': 'https://info-support.sungrowpower.com/application/pdf/2024/12/07/DS_20241204_SG5.0RS-ADA_8.0_10RS_Datasheet_V14_EN%EF%BC%88AU).pdf', 'title': 'SG5.0RS-ADA/SG8.0/10RS datasheet', 'doc_type': 'datasheet', 'publisher': 'Sungrow', 'revision': 'Version 14', 'doc_date': '2024-12-04', 'language': 'en', 'region': 'AU', 'accessed': '2026-09-01', 'confidence': 'officially-verified'}] |
| startup_voltage_v | 50 |
| string_rules | 3 independent MPPTs, 1 PV string per MPPT (3 strings total) |
| sunspec_support | UNKNOWN |
| thd | < 3 % at rated power |
| topology | grid-tie (transformerless string inverter, no battery interface) |
| voltage_range | 154 V - 276 V |
Physical / mechanical
| cooling | natural convection (fanless) |
| depth_mm | 170 |
| dimensions_mm | 490 (W) * 340 (H) * 170 (D) |
| enclosure_material | UNKNOWN |
| height_mm | 340 |
| mounting_bolt_size | UNKNOWN |
| mounting_hole_diameter_mm | UNKNOWN |
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_type | ['wall'] disputed |
| screw_sizes | UNKNOWN |
| shipping_weight_kg | UNKNOWN |
| torque_specs | UNKNOWN |
| weight_kg |
19
SG5.0RS-ADA/SG8.0/10RS Datasheet — 'Weight 19 kg', SG10RS column
|
| width_mm |
490
SG5.0RS-ADA/SG8.0/10RS Datasheet — 'Dimensions (W*H*D) 490 * 340 * 170 mm', SG10RS column
|
Installation
| ac_connector | plug-and-play connector (max. 16 mm2) |
| dc_connector | MC4 (max. 6 mm2) |
| direct_sunlight_restriction | UNKNOWN |
| indoor_outdoor | indoor and outdoor (IP65) |
| max_installation_altitude_m | 4000 |
| mounting_orientation | UNKNOWN (no official SG-RS installation manual could be retrieved this session) |
Environment
| cooling | natural cooling |
| cooling_method | natural cooling |
| corrosion_class |
C5
disputed
SG5.0RS-ADA/SG8.0/10RS Datasheet — 'Anti-corrosion class C5'
|
| fan_replaceable | N/A (fanless) |
| ip_rating | IP65 |
| max_altitude_m | 4000 |
| noise_db | UNKNOWN |
| noise_level_db | UNKNOWN |
| operating_temperature | -25 C to 60 C |
| operating_temperature_c | -25 to 60 |
| relative_humidity | 0 % - 100 % |
Interfaces & connectors
| ac_terminal_type | plug-and-play connector (max. 16 mm2) |
| bluetooth | UNKNOWN |
| can | none documented |
| communication_label | Ethernet / WLAN / RS485 / DI (Ripple control & DRM) |
| digital_inputs | DI for ripple control and DRM |
| display | LED digital display and LED indicator |
| ethernet | yes |
| isolarcloud_dependency | iSolarCloud for monitoring; no local-operation dependency stated |
| local_communication | RS485 / DI (ripple control and DRM) |
| logger_support | NOT_LISTED for SGxxRS in Compatibility List 4.3 |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| protocol_notes | Datasheet V14 'Communication: Ethernet / WLAN / RS485 / DI (Ripple control & DRM)' |
| pv_connector_type | MC4 (max. 6 mm2) |
| register_map_availability | UNKNOWN |
| rs485 | yes |
| wifi | yes (WLAN) |
| winet_support | yes - Compatibility List 4.3 lists WiNet-S/S2 for SGxxRS |
Controls & display
| display_type | LED digital display & LED indicator |
| leds | LED indicator |
| local_display | True |
| mobile_app | iSolarCloud |
| touchscreen | False |
Protection
| afci |
yes (integrated arc fault circuit interrupter)
disputed
SG5.0RS-ADA/SG8.0/10RS Datasheet — protection section 'AFCI: Yes'; product page bullet 'Integrated arc fault circuit interrupter'
|
| anti_islanding | yes (grid monitoring / islanding protection) disputed |
| dc_reverse_polarity | yes |
| dc_switch | yes |
| grid_protection | grid monitoring |
| ground_fault_protection | yes (ground fault monitoring) |
| insulation_monitoring | PV string current monitoring yes |
| integrated_dc_switch | True |
| pid | PID Zero function yes |
| rcmu | leakage current protection yes |
| residual_current_monitoring | yes (leakage current protection) |
| reverse_polarity | yes (DC reverse polarity protection) |
| short_circuit | yes (AC short-circuit protection) |
| spd | DC Type II / AC Type II |
| surge_protection | DC Type II / AC Type II (built-in) |
Certifications
| emc | [] |
| grid_codes | ['AS/NZS 4777.2:2020'] disputed |
| grid_support | active and reactive power control, power ramp rate control |
| other | [] |
| regional | [] |
| safety | ['IEC 62109-1', 'IEC 62109-2'] |
Warranty & service
| extension_options | UNKNOWN |
| note | no warranty statement appears in the fetched datasheet extraction |
| standard_warranty | UNKNOWN |
Documents
user-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
SG5.0RS-ADA / SG8.0RS / SG9.0RS / SG10RS User Manual (Ver15) — located, not retrieved
rev Ver15
Recorded conflicts
electrical.max_dc_short_circuit_current_total_a Review required
60 A total ('60 A (20 A / 20 A / 20 A)') — document[0]
30 A (single figure captured, per-MPPT breakdown not captured) — document[3]
electrical.max_input_current_per_mppt_a Review required
16 A per MPPT, 48 A total ('48 A (16 A / 16 A / 16 A)') — document[0]
20 A per MPPT, 60 A total ('60 A (20 A / 20 A / 20 A)') — document[3]
electrical.recommended_pv_power_w Review required
15000 W (15 kWp) — document[0]
12000 W (12 kWp) — document[3]
electrical.rated_ac_power_w / max_apparent_power_va Review required
10000 W / 10000 VA — document[0]
9999 W / 9999 VA — document[3]
electrical.max_short_circuit_current_per_mppt_a Review required
30 (fetched excerpt showed single figure 'Max DC short-circuit current 30 A'; per-MPPT vs total breakdown not captured) — stored value
20 — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
electrical.max_input_current_per_mppt_a Review required
20 (label 'Max. PV input current 60 A (20 A / 20 A / 20 A)') — stored value
16 — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
certifications.grid_codes Review required
['AS/NZS 4777.2:2020'] — stored value
['IEC/EN 62109-1/2', 'IEC/EN 62116', 'IEC/EN 61727', 'IEC/EN 61000-6-2/3', 'AS/NZS 4777.2', 'ABNT NBR 16149', 'ABNT NBR 16150', 'G99'] — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
protection.anti_islanding Review required
yes (grid monitoring / islanding protection) — stored value
yes — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
protection.afci Review required
yes (integrated arc fault circuit interrupter) — stored value
yes — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
environment.corrosion_class Review required
C5 — stored value
C5 (per the AU V14 sibling; not surfaced in the GL V12 extraction) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
physical.mounting_type Review required
['wall'] — stored value
['wall bracket'] — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
identity.generation Review required
RS string inverter — stored value
RS high-power (3-MPPT chassis, 490*340*170 mm) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
identity.market_version Review required
AU (AS/NZS 4777.2:2020) — stored value
GL (global) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
identity.product_family Review required
SG5.0RS-ADA / SG8.0RS / SG9.0RS / SG10RS — stored value
SG5.0RS-ADA / SG8.0RS / SG9.0RS / SG10RS (RS single-phase high-power, 3 MPPT) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Matching meter (SG5.0RS-ADA) | SG5.0RS-ADA matching single-phase wireless meter WiMeter-S |
| Max. efficiency / European efficiency | 97.8 % / 97.4 % |
| PID recovery function | Yes |
| Power factor | > 0.99 / 0.8 leading - 0.8 lagging |
| THD | < 3 % (at rated power) |
| identity.product_status | not listed on the official 2026 sungrowpower.com string-inverter index (which shows only SG3.0/3.6/4.0RS and SG5.0/6.0RS for 1-phase on the global site); the family remains current in AU and LATAM. Status recorded as regionally-scoped rather than globally-active. |
| identity.region_as_researched | GL (global datasheet V12); a separate AU datasheet V14 exists for AS/NZS 4777.2 markets |
| manufacturer_legal_entity_as_printed | Sungrow Power Supply Co., Ltd. |