Sunsynk SUNSYNK-8K-SG01LP1/SG02LP1
Official manufacturer EU/UK/ZA/AU (single datasheet, multiple grid codes) verified Sept. 2, 2026
UNKNOWN
Identity
| brand | Sunsynk |
| category | inverters |
| ean | UNKNOWN |
| generation | UNKNOWN |
| manufacturer | Sunsynk |
| market_version | UNKNOWN |
| model | SUNSYNK-8K-SG01LP1/SG02LP1 |
| mpn | UNKNOWN |
| product_family | Sunsynk 8kW single-phase LV hybrid (SUNSYNK-8K-SG01LP1 / SG02LP1 / SG03LP1) |
| product_revision | UNKNOWN |
| product_status | active |
| region | EU/UK/ZA/AU (single datasheet, multiple grid codes) |
| release_year | UNKNOWN |
| sku | SUNSYNK-8K-SG02LP1 (official Sunsynk product page 'Hybrid Inverter 8kW'; SG01LP1 is the sibling code) |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | UNKNOWN |
| battery_support | True |
| battery_type | Lead-acid or Li-Ion |
| battery_voltage_class | LV |
| battery_voltage_max_v | 60 |
| battery_voltage_min_v | 40 |
| communication_can | True |
| communication_ethernet | UNKNOWN |
| communication_rs485 | True |
| communication_wifi | UNKNOWN |
| ct_support | UNKNOWN |
| generator_input_support | UNKNOWN |
| grid_certifications | ['EN 50549-1', 'AS-NZS 4777.2', 'NRS 097-2-1', 'IEC/EN 61000-6-1/2/3/4', 'IEC/EN 62109-1', 'IEC/EN 62109-2'] |
| grid_export_control | UNKNOWN |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 8.8 |
| max_battery_charge_current_a | 190 |
| max_battery_charge_power_kw | UNKNOWN |
| max_battery_discharge_current_a | 190 |
| max_dc_voltage_v | 500 |
| max_input_current_per_mppt_a | 26 |
| max_pv_input_power_w | 10400 |
| max_short_circuit_current_per_mppt_a | 44 |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 425 |
| mppt_min_voltage_v | 150 |
| num_mppt | 2 |
| officially_supported_battery_brands | UNKNOWN (Sunsynk shares Deye's CAN/RS485 protocol; no separate Sunsynk-branded list found) |
| phase_type | single-phase |
| pv_inputs_per_mppt | 2 |
| rated_ac_power_kw | 8 |
| smart_meter_support | UNKNOWN |
| startup_voltage_v | 125 |
| sunspec_support | UNKNOWN |
| topology | hybrid |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | UNKNOWN |
| depth_mm | 233 |
| dimension_note | '420W x 670H x 233D (Excluding connectors and brackets)' - datasheet v.22 |
| drill_hole_depth_mm | 82-90 ('Choose the recommended drill head to drill 4 holes on the wall, 82-90mm deep' - manual p.14) |
| enclosure_material | UNKNOWN |
| height_mm | 670 |
| housing_color | White ('Colour White' - official product page) |
| mounting_bolt_size | UNKNOWN (manual specifies expansion bolts but not the size for the 8kW) |
| mounting_hole_diameter_mm | UNKNOWN |
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_plate_dimensions_mm | UNKNOWN |
| mounting_type | ['wall'] |
| screw_sizes | UNKNOWN |
| shipping_weight_kg | 38.5 |
| terminal_locations | UNKNOWN |
| torque_specs |
battery terminal 24.5 N.m max (1 AWG / 50 mm2, manual p.15-16); AC terminal 1.2 N.m max (10 AWG / 8 mm2, manual p.21); PV 12 AWG / 4 mm2, no torque given (manual p.23)
USER MANUAL SUNSYNK-8K-SG01LP1 / SUNSYNK-8K-SG03LP1 v.24 — p.15-16 battery '8kW 1 AWG 50 24.5N.m'; p.21 AC '8kW 10 AWG 8 1.2N.m'
|
| weight_kg |
32
Sunsynk Hybrid Inverter 8kW Datasheet v.22 (SUNSYNK-8K-SG01LP1 / SG02LP1) — spec table, 'Weight (net/gross) 32kg / 38.5kg'
|
| width_mm |
420
Sunsynk Hybrid Inverter 8kW Datasheet v.22 (SUNSYNK-8K-SG01LP1 / SG02LP1) — spec table, 'Size(W*H*D) 420W x 670H x 233D (Excluding connectors and brackets)'
|
Installation
| altitude_derating_note | manual p.13 forbids 'High altitude areas (over 2000 metres above sea level)' |
| clearance_bottom_mm | 500 |
| clearance_front_mm |
1000
USER MANUAL SUNSYNK-8K-SG01LP1 / SUNSYNK-8K-SG03LP1 v.24 — p.14, 'allow a clearance of approximately 500mm to the side, 500mm above and below the unit, and 1000mm to the front'
|
| clearance_left_mm | 500 |
| clearance_note | 'allow a clearance of approximately 500mm to the side, 500mm above and below the unit, and 1000mm to the front of the unit' - manual p.14 |
| clearance_right_mm | 500 |
| clearance_top_mm | 500 |
| direct_sunlight_restriction | UNKNOWN |
| forbidden_locations | areas with high salt content; areas filled with mineral oil; areas with sulphuric/chlorine gas, acid or alkali; combustible-gas areas; ammonia environments; altitude >2000 m; precipitation or humidity above 95% (manual p.13) |
| indoor_outdoor | indoor and outdoor (IP65) |
| installation_humidity_range | up to 95% ( >95% forbidden, manual p.13) |
| max_installation_altitude_m | 2000 |
| minimum_wall_thickness_mm | UNKNOWN |
| mounting_orientation | vertical wall mount, at eye level so the LCD can be read (manual p.13) |
| orientation_allowed | ['vertical'] |
| orientation_forbidden | UNKNOWN (manual states vertical wall only; no explicit forbidden-orientation list) |
| surface_requirements | 'Select a vertical wall with load-bearing capacity for installation, suitable for installation on concrete or other non-flammable surfaces' - manual p.13 |
| two_person_lift_required | UNKNOWN |
| ventilation_requirements | forced air circulation required for heat dissipation (manual p.14) |
Environment
| cooling_method | 'Smart cooling' (datasheet v.22) - fan-assisted; manual requires forced air circulation |
| corrosion_class | UNKNOWN |
| fan_replaceable | UNKNOWN |
| ik_rating | UNKNOWN |
| ip_rating |
IP65
Sunsynk Hybrid Inverter 8kW Datasheet v.22 (SUNSYNK-8K-SG01LP1 / SG02LP1) — spec table, 'Ingress Protection IP65'
|
| max_altitude_m | 2000 |
| nema_rating | UNKNOWN |
| noise_level_db | <30 dB |
| operating_temperature_c | -40 to +60 (>45 derating) [datasheet v.22] |
| pollution_degree | UNKNOWN |
| relative_humidity | up to 95% (installation limit; no separate operating RH row) |
| salt_mist_resistance | not suitable - 'Areas with high salt content' forbidden (manual p.13) |
| storage_temperature_c | -40 to +60 (transport/storage note, datasheet v.22) |
Interfaces & connectors
| ac_terminal_type | terminal block, 10 AWG / 8 mm2, 1.2 N.m (manual p.21) |
| backup_eps_terminal | yes - LOAD terminal, rated UPS/backup output 8000 W (datasheet v.22) |
| battery_terminal_type | bolted terminal, 1 AWG / 50 mm2 cable, 24.5 N.m (manual p.15-16) |
| bluetooth | UNKNOWN |
| can | yes - Battery CAN bus port; inverter-side Pin 4 CAN-H, Pin 5 CAN-L (manual p.84-85) |
| cellular | optional - GSM-Type Data Logger (manual Appendix E, p.85) |
| cloud_api | UNKNOWN |
| ct_interface | CT coil connection on the unit (manual p.7) |
| dry_contacts | function port present (manual p.17, 'Function Port Definition') |
| ethernet | optional - LAN-Type Data Logger (manual Appendix E, p.85) |
| generator_start_contact | UNKNOWN |
| generator_terminal | yes - GEN (generator) AC input terminal (manual p.7 product overview) |
| local_api | UNKNOWN |
| meter_interface | Meter_CON connection (manual p.7) |
| modbus_rtu | RS485 port labelled 'Modbus (RS-485)' in the Sunsynk family port list; register map not fetched |
| modbus_tcp | UNKNOWN |
| mqtt | UNKNOWN |
| parallel_port | yes (manual p.7) |
| protocol_notes | BMS CAN pin-out (battery side): Pin 1 CAN-H, Pin 5 CAN-L, pins 2/3/4/6/7/8 NC. RS485: Pin 1 RS485B, Pin 2 RS485A, Pins 3 and 6 GND (manual Appendix A, p.84-85). |
| pv_connector_type | UNKNOWN |
| relay_outputs | UNKNOWN (function port present, pin table not extracted for this model) |
| rs232 | documented in BMS appendix (Pin 3 BMS transmit, Pin 4 BMS receiver, Pin 5 GND - manual p.84-85) |
| rs485 | yes ('RS485; CAN' - datasheet v.22; Modbus RS485 port on unit) |
| smart_load_output | UNKNOWN |
| sunspec | UNKNOWN |
| usb | UNKNOWN |
| wifi | optional - Wi-Fi-Type Data Logger via WiFi interface (manual Appendix E, p.85) |
| zigbee | UNKNOWN |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | 4 - Esc, Up, Down, Enter (manual p.39) |
| display_type | LCD |
| leds | 4 - DC (green, PV connection normal), AC (green, grid normal), Normal (green, inverter functioning normally), Alarm (red, fault) - manual p.39 |
| local_display | True |
| mobile_app | SolarMan (manual Appendix C, p.85 - 'compatible with the SolarMan app, via a Wifi or GSM data logger'). Newer Sunsynk documentation for the same family names 'Sunsynk Connect'. |
| touchscreen | UNKNOWN |
| web_interface | UNKNOWN |
Protection
| afci |
yes - 'PV Arc Fault Detection' (datasheet v.22)
Sunsynk Hybrid Inverter 8kW Datasheet v.22 (SUNSYNK-8K-SG01LP1 / SG02LP1) — spec table, 'PV Arc Fault Detection'
|
| anti_islanding | yes - 'Anti-islanding Protection' (datasheet v.22) |
| export_limiting | yes - 'Limiting function installed to prevent excess power overflow to grid' (manual p.9) |
| ground_fault_protection | yes - earth connection mandatory, ground-fault detection provided (manual p.27) |
| insulation_monitoring | yes - 'Insulation Resistor Detection' (datasheet v.22) |
| integrated_dc_switch | yes - DC switch on the unit (Sunsynk family port list) |
| over_current | yes - overload protection (manual p.9) |
| over_temperature | yes - over-temperature protection (manual p.9); output derating above +45 C |
| overvoltage_category | UNKNOWN |
| protection_class | Class I (manual p.11, 'Protection Level Class I') |
| residual_current_monitoring | yes - 'Residual Current Monitoring Unit' (datasheet v.22) |
| short_circuit | yes - short-circuit protection (manual p.9) |
| surge_protection | 'DC Type II / AC Type II' (datasheet v.22) |
Certifications
| emc | ['IEC/EN 61000-6-1', 'IEC/EN 61000-6-2', 'IEC/EN 61000-6-3', 'IEC/EN 61000-6-4'] |
| grid_codes | ['EN 50549-1', 'AS-NZS 4777.2', 'NRS 097-2-1', 'VDE-AR-N 4105:1028-11 (as printed in manual p.12; almost certainly a typo for 2018-11)', 'DIN VDE V 0124-100:2020-06'] |
| other | [] |
| regional | [] |
| safety | ['IEC/EN 62109-1', 'IEC/EN 62109-2'] |
Warranty & service
| conditions | '5 years (10 years when installed with a Sunsynk battery)' - datasheet v.22 |
| design_life_years | UNKNOWN |
| extended_options_years | [10] |
| field_replaceable_parts | UNKNOWN |
| service_intervals | dust cleaning at least twice a year; weekly in dusty environments (manual p.83) |
| standard_years | 5 |
Documents
datasheet
Sunsynk Hybrid Inverter 8kW Datasheet v.22 (SUNSYNK-8K-SG01LP1 / SG02LP1)
rev v.22 (07/05/25)
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_battery
Deye AI-W5.1-B
COMPATIBLEmanufacturer-documented
Deye Approved Battery List DY-LV48-0109
Pytes V5 / V5-alpha (printed as V5° / V5°α)
COMPATIBLEofficially-verified
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Pytes E-Box 48100R
COMPATIBLEofficially-verified
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
BSLBATT B-LFP48-200E (19-inch rack battery, 10.24 kWh)
COMPATIBLEmanufacturer-documented
BSLBATT B-LFP48 Rack Battery Pack User Manual V2.7 CAN/RS485 protocol tables, https://bslbatt.com/wp-content/uploads/2024/09/B-LFP48-User-Manual-V2.7-Rack-Battery-Pack.pdf (fetched 2026-09-01)
BSLBATT B-LFP48-100E (3U Server Rack Battery)
COMPATIBLEmanufacturer-documented
BSLBATT B-LFP48 Rack Battery Pack User Manual V2.7 CAN/RS485 protocol tables, https://bslbatt.com/wp-content/uploads/2024/09/B-LFP48-User-Manual-V2.7-Rack-Battery-Pack.pdf (fetched 2026-09-01)
inverter_meter
CHINT DTSU666 (and DTSU666-CT variant)
COMPATIBLEofficially-verified
Deye-hosted CHINT DTSU666 manual PDF
inverter_evse
go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)
Recorded conflicts
environment.operating_temperature_c Review required
-40 to +60 (>45 derating) — Datasheet v.22 (07/05/25)
-45 to +60 (>45 derating) — User manual v.24 p.11, 'Ambient Temperature -45C ~ 60C'
document revision - the 2023 manual and the 2025 datasheet disagree on the low-temperature limit
physical.weight_kg Review required
32 — Sunsynk 8kW Datasheet v.22, 'Weight (net) 32kg'
31.9 — Sunsynk official product page /product/hybrid-inverter-8kw, 'Net Weight 31.9kg' (gross 38.1kg vs datasheet 38.5kg)
SG02LP1 variant vs the SG01LP1/SG02LP1 combined datasheet, or rounding in the web product card
environment.operating_temperature_c Review required
-40 to +60 (>45 derating) — Datasheet v.22 (07/05/25)
-45 to +60 (>45 derating) — User manual v.24 p.11, 'Ambient Temperature -45C ~ 60C'
document revision - the 2023 manual and the 2025 datasheet disagree on the low-temperature limit
physical.weight_kg Review required
32 — Sunsynk 8kW Datasheet v.22, 'Weight (net) 32kg'
31.9 — Sunsynk official product page /product/hybrid-inverter-8kw, 'Net Weight 31.9kg' (gross 38.1kg vs datasheet 38.5kg)
SG02LP1 variant vs the SG01LP1/SG02LP1 combined datasheet, or rounding in the web product card
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Cleaning interval | at least twice a year (weekly in dusty environments) |
| Peak Power (Off-Grid) | 16000W, 10 sec |
| Recommended AC breaker for backup load | 63A |