Page 1 of APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02 (https://global.apsystems.com/wp-content/uploads/2023/04/APsystems-Microinverter-DS3D-For-APAC-Datasheet_-Rev1.2_2023-03-02.pdf)
Identity
| brand | APsystems |
| category | microinverters |
| manufacturer | APsystems |
| manufacturer_key | apsystems |
| model | DS3D |
| model_key | ds3d |
| product_family | APsystems DS3 family |
| product_status | active |
| region | APAC |
| series | DS3 series (dual-module microinverter) |
Electrical
| ac_bus_cable |
2.5 mm2 (23 A) / 4 mm2 (28 A)
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| ac_phase_count |
1
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| cec_weighted_efficiency_pct |
96.7
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| communication_method |
Encrypted ZigBee (inverter to ECU)
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| cooling |
Natural Convection - No Fans
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| dc_connector_type |
Staubli MC4 PV-ADBP4-S2 & ADSP4-S2
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| dimensions_w_h_d_mm |
284 x 234 x 50.2
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| gateway_required |
True
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| gateway_required_note |
The datasheet's communication row is printed as 'Communication (Inverter To ECU): Encrypted ZigBee', i.e. an APsystems Energy Communication Unit is named as the counterpart. No specific ECU model is named, so no compatibility relationship is asserted.
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| grid_frequency_hz |
[50, 60]
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| grid_frequency_range_hz |
50 Hz/48-51 or 60 Hz/59.3-60.5 (adjustable 45-65 Hz)
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| grid_voltage_range_v |
184-253 (adjustable 180-270)
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| max_ac_current_a |
8.7
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| max_dc_voltage_label |
Maximum Input Voltage
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| max_dc_voltage_v |
118
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| max_input_current_per_input_a |
20
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| max_short_circuit_current_per_input_a |
25
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| maximum_units_per_branch |
{'2.5 mm2': 2, '4 mm2': 3}
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| mppt_voltage_label |
Peak Power Tracking Voltage
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| mppt_voltage_max_v |
90
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| mppt_voltage_min_v |
56
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| night_power_consumption_mw |
20
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| nominal_grid_voltage_v |
230
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| nominal_mppt_efficiency_pct |
99.5
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| number_of_mppt |
2
APsystems DS3D - APsystems EMEA product page
|
| number_of_mppt_note |
Taken from the APsystems EMEA DS3D product page, which states two input channels each with an independent MPPT; the APAC datasheet table itself prints no MPPT-count row.
APsystems DS3D - APsystems EMEA product page
|
| number_of_pv_inputs |
2
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| operating_voltage_range_v |
52-118
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| peak_efficiency_pct |
97.0
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| phase_count | 1 |
| rated_ac_power_w |
2000
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| recommended_module_power_max_w |
670
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| recommended_module_power_min_w |
315
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| recommended_module_power_note |
Printed as 'Recommended PV Module Power (STC) Range: 315Wp-670Wp+'
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
| strings_per_mppt_distribution |
[1, 1]
APsystems DS3D - APsystems EMEA product page
|
| topology |
High Frequency Transformers, Galvanically Isolated
APsystems Microinverter DS3D for APAC Datasheet, Rev1.2, 2023-03-02
|
Physical / mechanical
| weight_kg |
4.3
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
Environment
| operating_ambient_temperature_c |
-40 to +65
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
| storage_temperature_c |
-40 to +85
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
Interfaces & connectors
| documented_ports | [{'port_role': 'PV_IN', 'port_label_from_manual': 'DC input 1', 'port_type': 'Staubli MC4 PV-ADBP4-S2 & ADSP4-S2', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Input Data (DC)', 'quote': 'Maximum Input Current: 20A x 2; Isc PV: 25A x 2; Maximum Input Voltage: 118V', 'quantity': 1, 'max_voltage_v': 118, 'max_current_a': 20}, {'port_role': 'PV_IN', 'port_label_from_manual': 'DC input 2', 'port_type': 'Staubli MC4 PV-ADBP4-S2 & ADSP4-S2', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Input Data (DC)', 'quote': 'Maximum Input Current: 20A x 2; Isc PV: 25A x 2; Maximum Input Voltage: 118V', 'quantity': 1, 'max_voltage_v': 118, 'max_current_a': 20}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'AC Bus Cable', 'port_type': 'AC bus / branch cable', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Mechanical Data / Output Data (AC)', 'quote': 'AC Bus Cable: 2.5mm2(23A)/4mm2(28A); Maximum Units per 2.5mm2 Branch: 2; Maximum Units per 4mm2 Branch: 3', 'quantity': 1}] |
Protection
| ingress_protection |
IP67
APsystems Microinverter DS3D for APAC User Manual, Rev1.5, 2025-03-05
|
Documents
product_page
APsystems DS3D - APsystems EMEA product page
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| builder_completeness | complete |
| region_notes | The only APsystems specification table reachable for this model is the one marked 'For APAC' on global.apsystems.com, so the product is created at region APAC and the figures below are APAC figures. This is NOT the EU product: the APsystems EMEA DS3D page states a 1800 W maximum output while the APAC datasheet prints 2000 W, so the EU variant has a different electrical specification and was record |