Identity

category microinverters
manufacturer APsystems
model QS2
product_status active
region NA

Electrical

ac_voltage_range 240V/211.2V-264V; 208V/183.04V-228.8V
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
ac_voltage_v [240, 208]
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
dimensions_in 14.37 x 10.71 x 1.6
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
euro_efficiency_pct 96.5
gateway_required True
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
grid_frequency_hz 60
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
grid_frequency_range_hz 58.8-61.2 (HECO: 57-63)
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_continuous_ac_power_va 1920
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_dc_voltage_v 60
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_efficiency_pct 96.7
max_input_current_a 20
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_input_current_axis per input (20A x 4)
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_input_current_per_mppt_a 16.0
max_short_circuit_current_a 25
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_short_circuit_current_axis per input (25A x 4)
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_short_circuit_current_per_mppt_a 25.0
max_units_per_10awg_30a_branch 3@240V / 2@208V
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
max_units_per_12awg_20a_branch 2@240V / 1@208V
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
mppt_count 2
mppt_voltage_max_v 48
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
mppt_voltage_min_v 28
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
nominal_ac_voltage_v 230.0
nominal_frequency_hz 50.0
number_of_mppt 4
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
number_of_pv_inputs 4
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
phase_count 1
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
required_gateway APsystems ECU
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)

Physical / mechanical

weight_kg 6.6
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)

Environment

enclosure_rating Type 6
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)
ip_rating IP67
operating_temperature_max_c 60.0
operating_temperature_min_c -25.0

Interfaces & connectors

communications ['Encrypted ZigBee']
APsystems QS2 Single-phase Quad Microinverter Datasheet (APS-QS2-25, 2026-02-26 Rev)

Warranty & service

warranty_years 12