Knowledge Base › Microinverters
Deye SUN800G3-EU-230
Manufacturer documented EU verified Aug. 31, 2026
Identity
| brand | Deye |
| category | microinverters |
| generation | G3 |
| manufacturer | Deye |
| market_version | EU-230 (230 V / 184-265 V) |
| model | SUN800G3-EU-230 |
| product_family | SUN(300~2000)G3-EU-230 |
| product_status | superseded |
| region | EU |
| supersession_note | Not listed on deyeinverter.com/product/microinverter-1/ as of 2026-09-02; replaced in the EU range by the G4 SUN-M/D/S series (checked this session). |
Electrical
| ac_coupling_compatibility | UNKNOWN/uncertain - no cross-brand certification list found |
| ac_rated_power_w | 800 |
| grid_profiles | ['UL 1741', 'IEC 62109-1', 'IEC 62109-2', 'IEC 61000-6-1', 'IEC 61000-6-3', 'IEC 61000-3-2', 'IEC 61000-3-3', 'EN 50549-1', 'VDE 0126-1-1', 'VDE-AR-N 4105', 'ABNT NBR 16149', 'ABNT NBR 16150', 'ABNT NBR 62116', 'RD 1699', 'UNE 206006 IN', 'UNE 206007-1 IN', 'IEEE 1547'] |
| input_to_mppt_mapping | 2 physical DC inputs -> 2 MPPTs, 1:1. Deye G3 datasheet row 'Number of MPPT / Strings per MPPT | 2/1'; the SUN(600-1000)G3-EU-230 manual adds 'Each PV module has individual Maximum Peak Power Tracking (MPPT) controls'. |
| max_dc_input_power_w | 210-600W x2 |
| max_dc_voltage_v | 60 |
| max_input_current_a | 12.5A x2 |
| max_short_circuit_current_a | 16 |
| max_units_per_ac_branch | 6 (on a 25 A branch breaker, per the SUN(600-1000)G3-EU-230 manual Ver1.2) |
| monitoring_protocol | power line communication (PLC) / WiFi / Zigbee |
| mppt_range_v | 25-55 |
| num_mppt | 2 |
| physical_dc_inputs | 2 |
| supported_module_power_range_w | 60-72 cell PV modules (exact wattage range not itemized) |
Physical / mechanical
| depth_mm | 40 |
| height_mm | 230 |
| mounting_type | ['rooftop', 'module racking rail'] |
| weight_kg | 3.15 (manual Ver1.2) / 3.5 (2022 datasheet) - see data_conflicts |
| width_mm | 212 |
Installation
| clearance_bottom_mm | 15 (manual: 'Allow a minimum of 3/4 (1.5cm.) between the roof and the bottom of the Microinverter to allow proper air flow') |
Environment
| cooling_method | natural cooling (fanless) |
| ip_rating | IP67 |
| operating_temperature_c | -40 to +65 |
Interfaces & connectors
| cloud_api | SOLARMAN / Deye Cloud |
| protocol_notes | AC lead: 'TC-ER wire with a wire cross-section area of 3.33mm2', 120 mm long; male/female AC interconnection connectors sold separately. |
| wifi | built-in WiFi module (EU-230 units) |
| zigbee | supported on the G3 generation |
Protection
| anti_islanding | YES |
| ground_fault_protection | manual: 'An AC GFCI device should not be used to protect the dedicated circuit to the microinverter' |
Certifications
| emc | ['IEC 61000-6-1', 'IEC 61000-6-3', 'IEC 61000-3-2', 'IEC 61000-3-3'] |
| grid_codes | ['EN 50549-1', 'VDE 0126-1-1', 'VDE-AR-N 4105', 'RD 1699', 'UNE 206006 IN', 'UNE 206007-1 IN', 'IEEE 1547'] |
| other | ['UL 1741'] |
| regional | ['CE', 'INMETRO'] |
| safety | ['IEC 62109-1', 'IEC 62109-2'] |
Warranty & service
| conditions | Deye G3 datasheet 'Warranty 10 years' |
| standard_years | 10 |
Documents
installation-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Installation / User Manual SUN(300~2000)G3-EU-230 Ver1.2 — located, not retrieved
rev Ver1.2
Recorded conflicts
max_input_current_a / max_short_circuit_current_a Review required
12.5 A x2 input, 16 A Isc — existing ANMA record (Conrad-hosted Deye datasheet)
13 A per input — Deye G3 datasheet 2022, row 'Max. input Current'
13 A x2 input, 10 A short-circuit — SUN(600-1000)G3-EU-230 manual Ver1.2
three revisions of the same family's documentation; the manual's 10 A short-circuit figure is not coherent with a 13 A input rating
max_input_current_a / max_short_circuit_current_a Review required
12.5 A x2 input, 16 A Isc — existing ANMA record (Conrad-hosted Deye datasheet)
13 A per input — Deye G3 datasheet 2022, row 'Max. input Current'
13 A x2 input, 10 A short-circuit — SUN(600-1000)G3-EU-230 manual Ver1.2
three revisions of the same family's documentation; the manual's 10 A short-circuit figure is not coherent with a 13 A input rating
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Full Load MPPT Range | 33-55 V (SUN800G3) |
| Night Consumption | 50 mW |
| Recommended module power | 210-500 W x2 (manual Ver1.2) / 210~500 W (2022 datasheet) |