ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseMicroinverters

Deye SUN-M30/40/50G4-EU-Q0-I

Official manufacturer EU verified Sept. 2, 2026

Identity

brand Deye
category microinverters
ean UNKNOWN
generation G4
manufacturer Deye (Ningbo Deye Inverter Technology Co., Ltd.)
market_version EU 220/230 V 50/60 Hz
model SUN-M30/40/50G4-EU-Q0-I
mpn 30240102202419 (datasheet document code)
product_family SUN-M30/40/50G4-EU-Q0-I
product_status active
region EU
release_year UNKNOWN
sku UNKNOWN
variant_suffix_meaning '-I' = variant with integrated bidirectional metering / backflow prevention (~INFERRED from Deye's own wording on the SUN-M130-220G4-EU-Q0-I page; Deye does not restate it on this page)

Electrical

ac_coupling_compatibility UNKNOWN - no fetched Deye document pairs this microinverter with any hybrid inverter for AC coupling
ac_rated_power_w 300 (M30) / 400 (M40) / 500 (M50)
grid_profiles ['IEC 61727', 'IEC 62116', 'CEI 0-21', 'EN 50549', 'NRS 097', 'RD 140', 'UNE 217002', 'VDE-AR-N 4105', 'G98']
input_to_mppt_mapping 1 physical DC input -> 1 MPPT (1:1). Official row: 'No. of MPP Trackers/No. of String per MPP Tracker | 1/1', one PV module per unit.
max_dc_input_power_w Deye row 'Max. PV Input Power(W)': 210-420 (M30, 1 Piece) / 210-560 (M40) / 210-700 (M50) - this row states the per-module power window, not a single wattage
max_dc_voltage_v 60
max_input_current_a 15 (label 'Max. Operating PV Input Current(A)')
SUN-M30/40/50G4-EU-Q0-I product page (HTML technical specification table) — row 'Max. Operating PV Input Current(A)' = 15
max_short_circuit_current_a 22.5 (label 'Max. Input Short-Circuit Current (A)')
SUN-M30/40/50G4-EU-Q0-I product page (HTML technical specification table) — row 'Max. Input Short-Circuit Current (A)' = 22.5
max_units_per_ac_branch 17 (M30) / 13 (M40) / 10 (M50)
monitoring_protocol built-in WiFi datalogger -> Deye Cloud / SOLARMAN (no external DTU required)
mppt_range_v 25-55
num_mppt 1
SUN-M30/40/50G4-EU-Q0-I product page (HTML technical specification table) — row 'No. of MPP Trackers/No. of String per MPP Tracker' = 1/1
physical_dc_inputs 1
supported_module_power_range_w 210-420 (M30) / 210-560 (M40) / 210-700 (M50); 1 module per unit

Physical / mechanical

cable_entry_positions UNKNOWN
depth_mm 40
enclosure_material UNKNOWN
height_mm 190
housing_color UNKNOWN
mounting_bolt_size UNKNOWN
mounting_hole_spacing_mm UNKNOWN
mounting_type ['rooftop', 'module racking rail']
note 'Cabinet Size (W*H*D)[mm] 212*190*40 (Excluding connectors and brackets)'
torque_specs AC terminal 1.0 N.m (G4 microinverter manual)
weight_kg 2.7
width_mm 212
SUN-M30/40/50G4-EU-Q0-I product page (HTML technical specification table) — row 'Cabinet Size (W*H*D)[mm]' = 212*190*40

Installation

clearance_bottom_mm 13 (manual: 'Allow a minimum of 1.3 cm between the roof and the bottom of the Microinverter to allow proper air flow')
direct_sunlight_restriction manual: 'Do not place the inverters (including DC and AC connectors) where exposed to the sun, rain or snow'
indoor_outdoor outdoor (IP67)
max_installation_altitude_m 2000
mounting_orientation under the PV module on the racking; not specified as orientation-restricted
surface_requirements 'Mount one Microinverter at each of these locations using hardware recommended by your module racking vendor' - Deye publishes no bracket part number
two_person_lift_required False

Environment

cooling_method natural cooling (fanless)
corrosion_class UNKNOWN
fan_replaceable n/a (fanless)
ik_rating UNKNOWN
ip_rating IP 67
max_altitude_m 2000
nema_rating UNKNOWN
noise_level_db <= 25
operating_temperature_c -40 to +65 (>45 derating)
pollution_degree UNKNOWN
relative_humidity 0-100%
salt_mist_resistance UNKNOWN
storage_temperature_c UNKNOWN
uv_resistance UNKNOWN

Interfaces & connectors

ac_terminal_type pre-fitted TC-ER AC lead; Bus AC connector or T-connector system (see accessories)
bluetooth UNKNOWN
can UNKNOWN
cellular False
cloud_api Deye Cloud / SOLARMAN (pro.solarmanpv.com, home.solarmanpv.com)
ethernet False
local_api UNKNOWN (SOLARMAN logger web page at http://10.10.100.254 exists for the built-in datalogger, admin/admin - configuration only, not a documented data API)
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
mqtt UNKNOWN
protocol_notes Grid connection form L/N/PE - single phase only. Deye publishes NO three-phase microinverter.
pv_connector_type UNKNOWN (connector brand/type is not named in any fetched Deye microinverter document)
rs232 UNKNOWN
rs485 UNKNOWN
sunspec UNKNOWN
usb False
wifi built-in WiFi module, 2.400-2.4835 GHz, 20 dBm +/-2 dBm (row 'Communication Interface | Wi-Fi')
zigbee UNKNOWN (Zigbee/PLC exist on the older G3 generation and on the MECD gateway, not stated for G4)

Controls & display

audible_alarm UNKNOWN
buttons none
display_type none
leds status LED (GFDI fault indicated by 4x red flashes per manual)
local_display False
mobile_app SOLARMAN Smart (owner) / SOLARMAN Business (installer); Deye Cloud
touchscreen False
web_interface built-in logger local web page http://10.10.100.254 (default admin/admin)

Protection

afci UNKNOWN
anti_islanding YES (row 'Anti-islanding Protection')
ground_fault_protection UNKNOWN
insulation_monitoring YES (row 'Insulation Impedance Detection')
over_current YES (row 'AC Output Overcurrent Protection')
over_temperature YES (row 'Thermal Protection')
over_voltage YES (row 'AC Output Overvoltage Protection')
overvoltage_category OVC II(DC), OVC III(AC)
protection_class UNKNOWN
rapid_shutdown UNKNOWN
reverse_polarity YES (row 'DC Reverse Polarity Protection')
short_circuit YES (row 'AC Output Short Circuit Protection')
surge_protection TYPE II (AC)

Certifications

emc ['IEC/EN 61000-6-1', 'IEC/EN 61000-6-2', 'IEC/EN 61000-6-3', 'IEC/EN 61000-6-4']
grid_codes ['IEC 61727', 'IEC 62116', 'CEI 0-21', 'EN 50549', 'NRS 097', 'RD 140', 'UNE 217002', 'VDE-AR-N 4105', 'G98']
other ['RED 2014/53/EU', 'RoHS 2011/65/EU']
regional ['CE']
safety ['IEC/EN 62109-1', 'IEC/EN 62109-2']

Warranty & service

conditions product page row 'Warranty [year] | 15 Years'
design_life_years UNKNOWN
field_replaceable_parts []
standard_years 15

Documents

certificate {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} EU Declaration of Conformity SUN-M30-50G4-EU-Q0 — located, not retrieved rev UNKNOWN
datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Datasheet SUN-M30/40/50G4-EU-Q0-I — located, not retrieved rev 20250520
datasheet SUN-M30/40/50G4-EU-Q0-I product page (HTML technical specification table)
installation-manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Installation / User Manual SUN-M30-50G4-EU-Q0 230V Ver1.5 — located, not retrieved rev Ver1.5

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

DC Injection Current<0.5%In
Inverter TopologyIsolated
Max. Efficiency / Euro Efficiency / MPPT Efficiency96.5% / 96.0% / >99%
Max. unit per branch17 / 13 / 10
Power Factor Adjustment Range0.9 leading to 0.9 lagging
Rated PV Input voltage(V)42.5
Total Current Harmonic Distortion THDi<3%

Build a system with this product