ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseMicroinverters

Enphase IQ8+

Official manufacturer NA verified Sept. 2, 2026

Identity

category microinverters
generation IQ8
manufacturer Enphase
market_version US/Canada, 240 V split-phase (L-L, 180 deg)
model IQ8+
product_family IQ8 Series Microinverters
product_status active
region NA
sku UNKNOWN (IQ8PLUS-72-2-US family; not printed in the fetched IQ8-series datasheet column)

Electrical

ac_coupling_compatibility UNKNOWN (no Enphase document fetched states third-party AC-coupling certification)
ac_rated_power_w 290
grid_profiles ['CA Rule 21 (UL 1741-SA)', 'IEEE 1547:2018 (UL 1741-SB 3rd Ed.)']
max_dc_input_power_w ~720 (derived from 12A x 60V, not an explicitly stated single figure)
max_dc_voltage_v 60
max_input_current_a 12
max_short_circuit_current_a 25
monitoring_protocol Power line communication (PLC) to Enphase Envoy
mppt_range_v 27-45
num_mppt UNKNOWN (single-input per unit; not explicitly stated as a count)
supported_module_power_range_w 235-440

Physical / mechanical

depth_mm 30.2
enclosure_material Class II double-insulated, corrosion-resistant polymeric enclosure
height_mm 212
mounting_bolt_size 6 mm (1/4 in) or 8 mm (5/16 in) racking hardware
mounting_type ['rooftop']
torque_specs 6 mm (1/4 in): 5 N.m (45-50 in-lb); 8 mm (5/16 in): 9 N.m (80-85 in-lb) - IQ8 series installation manual p.17
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters — installation manual p.17
weight_kg 1.1
DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) — MECHANICAL DATA, '1.1 kg (2.3 lb)'
width_mm 175
DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) — MECHANICAL DATA, 'Dimensions (H x W x D) 212 mm x 175 mm x 30.2 mm'

Installation

clearance_bottom_mm 19
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters — installation manual p.17
clearance_top_mm 13
direct_sunlight_restriction Always place the microinverter under the PV module, protected from direct exposure to rain, sun and other harmful weather events (manual p.17)
indoor_outdoor outdoor, wet-location approved (NEMA 250 type 6)
installation_notes Vertical mount requires >30 cm (12 in) clearance from the edges of the PV module (manual p.17).
mounting_orientation horizontal (bracket side up) or vertical, mounted under the PV module
orientation_allowed ['horizontal (bracket side up)', 'vertical']
orientation_forbidden ['upside down']

Environment

cooling_method natural convection - no fans
ip_rating UNKNOWN (NEMA-rated rather than IP-rated)
nema_rating NEMA 250, type 6
operating_temperature_c -40 to +60
storage_temperature_c UNKNOWN

Interfaces & connectors

ac_terminal_type Enphase IQ Connector on IQ Cable (12 AWG double-insulated outdoor trunk cable)
can False
cloud_api Enphase Enlighten (via IQ Gateway)
ethernet False
powerline_communication proprietary PLC to IQ Gateway (Envoy)
protocol_notes No IP/Modbus/serial interface on the microinverter itself.
pv_connector_type Enphase IQ DC connector; MC4 via Q-DCC-2 adapter cable
rs485 False
wifi False

Controls & display

display_type none
leds flashing green = normal operation + IQ Gateway communication; flashing orange = grid normal but no gateway communication; flashing red = AC grid absent or out of specification; solid red = DC Resistance Low, Power Off (manual p.26)
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters — installation manual p.26
local_display False

Protection

anti_islanding yes (IEEE 1547:2018 / UL 1741-SB 3rd Ed. listing)
ground_fault_protection DC Resistance Low detection (solid red LED)
overvoltage_category Overvoltage class DC port: II
protection_class Class II double-insulated

Certifications

emc ['FCC Part 15 Class B', 'ICES-0003 Class B']
grid_codes ['CA Rule 21 (UL 1741-SA)', 'IEEE 1547:2018 (UL 1741-SB 3rd Ed.)']
DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) — Compliance row of the IQ8 series datasheet
other []
regional []
safety ['UL 62109-1', 'CAN/CSA-C22.2 NO. 107.1-01']

Warranty & service

design_life_years UNKNOWN
standard_years up to 25 (limited warranty per datasheet wording)

Documents

datasheet DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) rev DSH-00412-5.0-EN-2025-10-10
installation-manual Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters
product-page Enphase Microinverters (installer product page)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

AC short circuit fault current over 3 cycles2 Arms
CEC weighted efficiency97 %
DC port backfeed current0 mA
Extended frequency range47-68 Hz
Max continuous output current1.21 A
Max units per 20A branch circuit13
Min/Max start voltage22/58 V
Nominal voltage/range240, split-phase (L-L), 180 deg
Operating range16-58 V
PV array configurationUngrounded array; no additional DC side protection required
Peak output power300 VA

Build a system with this product