category microinverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation —
manufacturer Hoymiles
market_version EU (EN 50549-1:2019 / VDE-AR-N 4105:2018 / VFR2019)
model HMS-1000-2T
mpn —
product_family HMS
product_status active
region EU
release_year —
series HMS-2T (single-phase, two-module)
sku —

Electrical

ac_connection —
ac_voltage_range 180-275 V
battery_capacity_range_kwh —
battery_communication —
battery_max_charge_current_a —
battery_max_charge_power_w —
battery_max_discharge_current_a —
battery_max_discharge_power_w —
battery_nominal_battery_voltage_v —
battery_type N/A - not a battery-capable product
battery_voltage_range_v —
eps_peak_power —
eps_phase —
eps_rated_power_va —
eps_switchover_time_ms —
eps_voltage —
european_efficiency_pct —
external_transfer_switch_required —
frequency_range_hz 45-55
inrush_current —
max_ac_active_power_w —
max_ac_current_a 4.35
max_apparent_power_va 1000
max_backfeed_current_a —
max_dc_input_power_w —
max_dc_voltage_v 65
max_efficiency_pct 96.5
max_input_current_per_mppt_a 16
max_output_fault_current_a —
max_short_circuit_current_per_mppt_a 2 x 25 A
mppt_efficiency_pct 99.8
mppt_voltage_range_v 16-60 V
night_self_consumption_w < 50 mW
nominal_ac_voltage 230 V
nominal_dc_voltage_v —
nominal_frequency_hz 50
number_of_mppt 2
parallel_capability —
phase_count 1
power_factor_range > 0.99 default, 0.8 leading ... 0.8 lagging
rated_ac_power_w —
rated_mppt_voltage_range_v —
startup_voltage_v 22
strings_per_mppt 1
thd_pct < 3

Physical / mechanical

ac_terminal —
cooling Natural convection - No fans
dc_connector —
depth_mm 35.1
dimensions_mm 261 x 180 x 35.1
display —
enclosure_material —
height_mm 180
mounting —
noise_db —
weight_kg 3.2
width_mm 261

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection Outdoor-IP67 (NEMA 6)
max_altitude_m —
operating_temperature_c -40 to +65
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app —
communication ['Sub-1G']
dry_contact —
meter_interface —
monitoring_portal Hoymiles S-Miles Cloud
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Certifications

standards ['EN 50549-1: 2019', 'VDE-AR-N 4105: 2018', 'VFR2019', 'IEC/EN 62109-1/-2', 'IEC/EN 61000-6-1/-2/-3/-4', 'IEC/EN 61000-3-2/-3']

Warranty & service

conditions —
extension_options —
standard_years —

Documents

datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Datasheet HMS-600/700/800/900/1000-2T (EU, EN) - download page — located, not retrieved rev UNKNOWN
product-page HMS-600&700&800&900&1000-2T - All Products - Hoymiles rev UNKNOWN
user-manual Single-phase Microinverter HMS-600-2T / HMS-700-2T / HMS-800-2T / HMS-900-2T / HMS-1000-2T (EU) rev V202302

Recorded conflicts

electrical.max_input_current_per_mppt_a Review required
2 x 16 A — Hoymiles EU manual HMS-600/700/800/900/1000-2T V202302
2 x 14 A — Hoymiles official product page HMS-600&700&800&900&1000-2T (tech specs table, read 2026-09-12)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

CEC peak efficiency96.5%
CEC peak efficiency - column HMS-1000-2T96.5%
Commonly used module power (W)400-670+ W
Commonly used module power (W) - column HMS-1000-2T400-670+
Hoymiles HMS-2T datasheet, row 'Maximum units per 12AWG branch'7 | 6 | 5 | 5 | 4
Isolation typeGalvanically Isolated HF Transformer
Maximum units per 10AWG / 12AWG branch - column HMS-1000-2T7 / 4
Maximum units per 10AWG branch7
Maximum units per 12AWG branch4
Mechanical - column HMS-1000-2T261 x 180 x 35.1 mm; 3.2 kg; natural convection - no fans
Nominal MPPT efficiency / night power99.8% / <50 mW
Number of Inputs per MPPT1
Rated output power (VA)1000
battery.communicationUNKNOWN
battery.max_charge_current_aUNKNOWN
battery.max_charge_power_wUNKNOWN
battery.max_discharge_current_aUNKNOWN
battery.max_discharge_power_wUNKNOWN
battery.nominal_battery_voltage_vUNKNOWN
withheld:ac.max_ac_current_a"UNKNOWN - only 'Rated output current' is printed"
withheld:ac.max_ac_power_w"UNKNOWN - this datasheet prints no peak / maximum output power row"
withheld:dc.max_dc_input_power_w"UNKNOWN - not printed"
withheld:dc.max_module_power_per_input_w"UNKNOWN - the module row is an open-ended 'commonly used' range ending in '+', not a published ceiling"
withheld:safety.max_altitude_m"UNKNOWN - not printed"
withheld:safety.max_branch_current_a"UNKNOWN - not printed"
withheld:safety.overcurrent_protection_requirement_a"UNKNOWN - not printed"
withheld:safety.protection_class"UNKNOWN - not printed"
withheld:topology.ac_output_connector"UNKNOWN - not printed on this sheet"