Knowledge Base › Microinverters
Hoymiles HMS-1800-4T-NA
Official manufacturer NA verified Sept. 23, 2026
Page 1 of Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America) (https://www.hoymiles.com/uploadfile/1/202506/ddf2f7ae73.pdf)
Identity
| brand | Hoymiles |
| category | microinverters |
| manufacturer | Hoymiles |
| manufacturer_key | hoymiles |
| model | HMS-1800-4T-NA |
| model_key | hms18004tna |
| product_family | Hoymiles HMS series |
| product_status | active |
| region | NA |
| series | HMS-4T-NA (4-in-1 single-phase microinverter, North America) |
Electrical
| ac_phase_count |
1
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| communication_method |
Sub-1G
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| cooling |
Natural convection-No fans
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| dimensions_w_h_d_in |
13.03 x 8.58 x 1.60
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| grid_frequency_hz |
60
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| grid_frequency_range_hz |
55-65
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| grid_voltage_range_v |
240/211-264 and 208/183-228
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| max_ac_current_a |
[6.92, 7.98]
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| max_ac_current_axis |
[240 V nominal, 208 V nominal]
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| max_dc_voltage_v |
65
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| max_input_current_per_input_a |
15
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| max_short_circuit_current_per_input_a |
25
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| maximum_units_per_branch |
{'10 AWG @ 240 V': 3, '10 AWG @ 208 V': 3}
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| monitoring_platform |
S-Miles Cloud
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| mppt_voltage_max_v |
60
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| mppt_voltage_min_v |
16
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| night_power_consumption_mw |
< 50
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| nominal_grid_voltage_v |
[240, 208]
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| nominal_mppt_efficiency_pct |
99.8
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| number_of_mppt |
4
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| number_of_pv_inputs |
4
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| peak_ac_power_va |
1800
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| peak_efficiency_pct |
96.5
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| phase_count | 1 |
| power_factor |
> 0.99 default, 0.8 leading … 0.8 lagging (adjustable)
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| pv_rapid_shutdown |
Listed on the datasheet as a compliance item for all three models in the table
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| rated_ac_power_note |
The NA datasheet prints 'Peak output power (VA)' = 1800 and 'Maximum continuous output power (VA)' = 1660; the continuous figure is recorded as the rated AC power.
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| rated_ac_power_w |
1660
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| recommended_module_power_max_w |
600
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| recommended_module_power_min_w |
360
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| startup_voltage_v |
22
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| strings_per_mppt_distribution |
[1, 1, 1, 1]
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| topology |
Galvanically Isolated HF Transformer
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| total_harmonic_distortion_pct |
< 3
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
| weight_lb |
12.26
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
Environment
| operating_ambient_temperature_f |
-40 to +149
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
Interfaces & connectors
| documented_ports | [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV input 1 (MPPT 1)', 'port_type': 'PV DC input', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Input Data (DC)', 'quote': 'Number of MPPTs: 4; Number of inputs per MPPT: 1; Maximum input current (A): 4 x 15', 'quantity': 1, 'max_voltage_v': 65, 'max_current_a': 15}, {'port_role': 'PV_IN', 'port_label_from_manual': 'PV input 2 (MPPT 2)', 'port_type': 'PV DC input', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Input Data (DC)', 'quote': 'Number of MPPTs: 4; Number of inputs per MPPT: 1; Maximum input current (A): 4 x 15', 'quantity': 1, 'max_voltage_v': 65, 'max_current_a': 15}, {'port_role': 'PV_IN', 'port_label_from_manual': 'PV input 3 (MPPT 3)', 'port_type': 'PV DC input', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Input Data (DC)', 'quote': 'Number of MPPTs: 4; Number of inputs per MPPT: 1; Maximum input current (A): 4 x 15', 'quantity': 1, 'max_voltage_v': 65, 'max_current_a': 15}, {'port_role': 'PV_IN', 'port_label_from_manual': 'PV input 4 (MPPT 4)', 'port_type': 'PV DC input', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Input Data (DC)', 'quote': 'Number of MPPTs: 4; Number of inputs per MPPT: 1; Maximum input current (A): 4 x 15', 'quantity': 1, 'max_voltage_v': 65, 'max_current_a': 15}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'AC output (10 AWG branch)', 'port_type': 'AC trunk connector', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Output Data (AC)', 'quote': 'Maximum units per 10 AWG branch: 3 at 240 V, 3 at 208 V', 'quantity': 1}] |
Protection
| ingress_protection |
Outdoor-NEMA 6 (IP67)
Microinverter Datasheet — HMS-1600-4T-NA / HMS-1800-4T-NA / HMS-2000-4T-NA (North America)
|
Documents
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| builder_completeness | partial |
| region_notes | Hoymiles publishes a separate North America datasheet for the -NA designation with 240 V / 208 V 60 Hz settings and imperial mechanical data. ANMA already holds HMS-2000-4T-NA from the same table. |