Knowledge Base › Microinverters
NEP (Northern Electric Power) BDHX-1000
Official manufacturer GLOBAL verified Sept. 22, 2026
Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Identity
| brand | NEP (Northern Electric Power) |
| category | microinverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | — |
| manufacturer | NEP (Northern Electric Power) |
| manufacturer_key | nep |
| market_version | — |
| model | BDHX-1000 |
| model_key | bdhx1000 |
| mpn | — |
| product_family | BDHX |
| product_status | active |
| region | GLOBAL |
| release_year | — |
| series | — |
| sku | — |
Electrical
| ac_charge_rated_power_w |
1000
NEP-branded BDHX-1000/2000 brochure PDF (hosted on ENF CDN; manufacturer-authored, third-party hosted)
|
| ac_voltage_range | — |
| battery_chemistry |
LFP
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| battery_supported |
True
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| battery_voltage_max_v |
60
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| battery_voltage_min_v |
40
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| cec_efficiency_pct | — |
| european_efficiency_pct | — |
| frequency_range_hz | — |
| max_ac_current_a | 4.35 |
| max_apparent_power_va | 1000 |
| max_dc_input_power_w | — |
| max_dc_voltage_v | 60 |
| max_discharge_power_w |
1000
NEP-branded BDHX-1000/2000 brochure PDF (hosted on ENF CDN; manufacturer-authored, third-party hosted)
|
| max_efficiency_pct | — |
| max_input_current_per_mppt_a | — |
| max_pv_charge_current_a |
20
NEP-branded BDHX-1000/2000 brochure PDF (hosted on ENF CDN; manufacturer-authored, third-party hosted)
|
| max_short_circuit_current_per_mppt_a | — |
| mppt_voltage_max_v |
55
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| mppt_voltage_min_v |
22
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| mppt_voltage_range_v | 22-55V |
| nominal_ac_voltage | 230V |
| nominal_frequency_hz |
[50, 60]
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| number_of_mppt | 2 |
| number_of_pv_inputs | — |
| offgrid_max_ac_output_power_w |
2000
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| offgrid_rated_ac_output_power_va |
1000
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| phase_count | 1 |
| rated_ac_output_voltage_v |
230
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| rated_ac_power_w | 1000 |
| startup_voltage_v |
25
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| units_per_branch | — |
Physical / mechanical
| ac_terminal | — |
| cooling | — |
| dc_connector | — |
| depth_mm | — |
| dimensions_mm | — |
| display | — |
| enclosure_material | — |
| height_mm | — |
| mounting | — |
| noise_db | — |
| weight_kg | — |
| width_mm | — |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | NEMA-6/IP-66/IP-67 |
| max_altitude_m | — |
| operating_temperature_c | — |
| pollution_degree | — |
| protective_class | — |
| relative_humidity_pct | — |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | [] disputed |
| dry_contact | — |
| meter_interface | — |
| monitoring_portal | — |
| protocols | [] |
Protection
| anti_islanding | — |
| arc_fault | — |
| dc_switch | — |
| insulation_monitoring | — |
| overvoltage_category | — |
| pv_overvoltage_protection_category |
II
BDHX-1000/2000 - Northern Electric Power technology Inc.
|
| rcmu | — |
| reverse_polarity | — |
| surge_protection_ac | — |
| surge_protection_dc | — |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | — |
Documents
directory_listing
ENF Inverter Directory - NEP BDHX-1000/BDHX-2000 hybrid micro inverter datasheet page
product-page
BDHX-1000 / BDHX-2000 | NEP microinverters
product_image
PRODUCT PHOTO
Recorded conflicts
ingress_protection Review required
NEMA-6/IP-66/IP-67 — value currently stored in ANMA
IP65 — https://eu.northernep.com/proinfo/33.html
document-revision
interfaces.communication Review required
[] — stored value
['Wi-Fi', 'Bluetooth'] — incoming package
Detected during import wave8-saturation-2026-09-batch02
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| ENF directory, 'Max. AC Power' / 'Nominal AC Power' | 2 kW / 1 kW |
| ENF directory, 'Max. DC Current' | 40 A |
| ENF directory, 'Max. Efficiency' / 'Power Consumption at Night' | 97.2 % / < 100 W |
| ENF directory, 'Min. DC Voltage to Start Feed In' | 22 V |
| ENF directory, 'Protection Class' | IP67 |
| Efficiency | Up to 95.5% CEC |
| Input Voltage (Max) / Maximum Current | 60 volts / 12 Amps |
| Maximum DC input current / Maximum short-circuit current | 20A (with 2 PV inputs) |
| NEP Europe / NEP brochure, 'Max DC Short Circuit Current' | 20 x 2 |
| NEP brochure opening line | Combining PV battery AC coupling on/off-grid NEP offers an all-in-one residential energy solution |
| Number of PV Inputs | 2 |
| Operating Temperature | -40°F to +185°F |
| category index card title | BDHX-1000/2000 |
| northernep.com BDHX product page boilerplate | V in 60 volts maximum / I max 12 Amps V network / V red 120 Volts AC / up to 95.5% / NEMA-6 IP-66 IP-67 / -40F to +185F |
| withheld:ac.ac_voltage_range_detail | "Published only in the ENF directory listing; NEP's own page prints no AC voltage range. Marked distributor-sourced." |
| withheld:dc.max_input_current_note | "NEP publishes NO operating input-current row for the BDHX at all - only a short-circuit row. The ENF directory's 'Max. DC Current 40 A / 80 A' is a DEVICE TOTAL (it equals the Isc row multiplied out) and was not divided down to a per-input or per-MPPT figure." |
| withheld:safety.ingress_protection | "IP65" |
| withheld:storage.note | "The BDHX is a HYBRID AC-coupled microinverter with integrated battery charge/discharge and a UPS function, not a plain grid-tie microinverter. Recorded for context; these fields are outside the wave's field vocabulary." |
| withheld:topology.mppt_independence_detail | "NOT PUBLISHED. The EU table gives two PV inputs ('600 x 2') and a short-circuit row of '20 x 2', so 20 A is the per-input limit; whether the two inputs sit on one tracker or two is not stated anywhere, so number_of_mppt and the per-MPPT limit remain UNKNOWN." |