⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Microinverters

NEP (Northern Electric Power) BDHX-2000

Official manufacturer GLOBAL verified Sept. 22, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

brand NEP (Northern Electric Power)
category microinverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation —
manufacturer NEP (Northern Electric Power)
manufacturer_key nep
market_version —
model BDHX-2000
model_key bdhx2000
mpn —
product_family BDHX
product_status active
region GLOBAL
release_year —
series —
sku —

Electrical

ac_charge_rated_power_w 2000
NEP-branded BDHX-1000/2000 brochure PDF (hosted on ENF CDN; manufacturer-authored, third-party hosted)
ac_voltage_range —
battery_chemistry LFP
BDHX-1000/2000 - Northern Electric Power technology Inc.
battery_supported True
BDHX-1000/2000 - Northern Electric Power technology Inc.
battery_voltage_max_v 60
BDHX-1000/2000 - Northern Electric Power technology Inc.
battery_voltage_min_v 40
BDHX-1000/2000 - Northern Electric Power technology Inc.
cec_efficiency_pct —
european_efficiency_pct —
frequency_range_hz —
max_ac_current_a 8.69
max_apparent_power_va 2000
max_dc_input_power_w —
max_dc_voltage_v 60
max_discharge_power_w 2000
NEP-branded BDHX-1000/2000 brochure PDF (hosted on ENF CDN; manufacturer-authored, third-party hosted)
max_efficiency_pct —
max_input_current_per_mppt_a —
max_pv_charge_current_a 40
NEP-branded BDHX-1000/2000 brochure PDF (hosted on ENF CDN; manufacturer-authored, third-party hosted)
max_short_circuit_current_per_input_a 40
BDHX-1000/2000 - Northern Electric Power technology Inc.
max_short_circuit_current_per_mppt_a —
mppt_voltage_max_v 55
BDHX-1000/2000 - Northern Electric Power technology Inc.
mppt_voltage_min_v 22
BDHX-1000/2000 - Northern Electric Power technology Inc.
mppt_voltage_range_v 22-55V
nominal_ac_voltage 230V
nominal_frequency_hz [50, 60]
BDHX-1000/2000 - Northern Electric Power technology Inc.
number_of_mppt 1
number_of_pv_inputs —
offgrid_max_ac_output_power_w 3000
BDHX-1000/2000 - Northern Electric Power technology Inc.
offgrid_rated_ac_output_power_va 2000
BDHX-1000/2000 - Northern Electric Power technology Inc.
phase_count 1
rated_ac_output_voltage_v 230
BDHX-1000/2000 - Northern Electric Power technology Inc.
rated_ac_power_w 2000
startup_voltage_v 25
BDHX-1000/2000 - Northern Electric Power technology Inc.
units_per_branch —

Physical / mechanical

ac_terminal —
cooling —
dc_connector —
depth_mm —
dimensions_mm —
display —
enclosure_material —
height_mm —
mounting —
noise_db —
weight_kg —
width_mm —

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection NEMA-6/IP-66/IP-67
max_altitude_m —
operating_temperature_c —
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app —
communication [] disputed
dry_contact —
meter_interface —
monitoring_portal —
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
pv_overvoltage_protection_category II
BDHX-1000/2000 - Northern Electric Power technology Inc.
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Warranty & service

conditions —
extension_options —
standard_years —

Documents

datasheet NEP-branded BDHX-1000/2000 brochure PDF (hosted on ENF CDN; manufacturer-authored, third-party hosted)
directory_listing ENF Inverter Directory - NEP BDHX-1000/BDHX-2000 hybrid micro inverter datasheet page
product-page BDHX-1000 / BDHX-2000 | NEP microinverters
product-page BDHX-1000/2000 - Northern Electric Power technology Inc.
product-page Microinverters | NEP - Northern Electric Power rev UNKNOWN
product_image PRODUCT PHOTO

Recorded conflicts

max_ac_current_a Resolved — regional/revision difference
8.69 —
4.35 —
max_ac_current_a Resolved — regional/revision difference
8.69 —
4.35 —
ingress_protection Review required
NEMA-6/IP-66/IP-67 — value currently stored in ANMA
IP65 — https://eu.northernep.com/proinfo/33.html
document-revision
interfaces.communication Review required
[] — stored value
['Wi-Fi', 'Bluetooth'] — incoming package
Detected during import wave8-saturation-2026-09-batch02

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

ENF directory, 'Max. AC Power' / 'Nominal AC Power'3 kW / 2 kW
ENF directory, 'Max. DC Current'80 A
ENF directory, 'Max. Efficiency' / 'Power Consumption at Night'97.2 % / < 150 W
ENF directory, 'Min. DC Voltage to Start Feed In'22 V
ENF directory, 'Protection Class'IP67
EfficiencyUp to 95.5% CEC
Input Voltage (Max) / Maximum Current60 volts / 12 Amps
Maximum DC input current / Maximum short-circuit current40A (with 4 PV inputs)
NEP Europe / NEP brochure, 'Max DC Short Circuit Current'40 x 2
NEP brochure opening lineCombining PV battery AC coupling on/off-grid NEP offers an all-in-one residential energy solution
Number of PV Inputs4
Operating Temperature-40°F to +185°F
category index card titleBDHX-1000/2000
northernep.com BDHX product page boilerplateV in 60 volts maximum / I max 12 Amps V network / V red 120 Volts AC / up to 95.5% / NEMA-6 IP-66 IP-67 / -40F to +185F
withheld:ac.ac_voltage_range_detail"Published only in the ENF directory listing; NEP's own page prints no AC voltage range. Marked distributor-sourced."
withheld:dc.max_input_current_note"NEP publishes NO operating input-current row for the BDHX at all - only a short-circuit row. The ENF directory's 'Max. DC Current 40 A / 80 A' is a DEVICE TOTAL (it equals the Isc row multiplied out) and was not divided down to a per-input or per-MPPT figure."
withheld:safety.ingress_protection"IP65"
withheld:storage.note"The BDHX is a HYBRID AC-coupled microinverter with integrated battery charge/discharge and a UPS function, not a plain grid-tie microinverter. Recorded for context; these fields are outside the wave's field vocabulary."
withheld:topology.mppt_independence_detail"NOT PUBLISHED, AND THE PRINTED NOTATION IS INTERNALLY AMBIGUOUS. NEP's own EU table gives the BDHX-2000 four PV inputs ('Recommended PV Module Power 600 x 4') but states its short-circuit limit as '40 x 2' - a multiplier of 2 against an input count of 4. The BDHX-1000, with two inputs, is '20 x 2'.