⚡ANMASystem BuildingAutomation, Network, Monitoring & Analytics
★PREMIUM

Knowledge Base › Microinverters

NEP (Northern Electric Power) BDM-1200-LV

Official manufacturer GLOBAL verified Sept. 22, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

brand NEP (Northern Electric Power)
category microinverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation —
manufacturer NEP (Northern Electric Power)
manufacturer_key nep
market_version —
model BDM-1200-LV
model_key bdm1200lv
mpn —
product_family BDM-1200-LV / BDM-1600-LV
product_status active
region GLOBAL
release_year —
series —
sku —

Electrical

ac_voltage_range —
cec_efficiency_pct —
european_efficiency_pct —
frequency_range_hz —
max_ac_current_a —
max_apparent_power_va —
max_dc_input_power_w —
max_dc_voltage_v 60
max_efficiency_pct 97
max_input_current_per_input_a 25
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
max_input_current_per_mppt_a —
max_short_circuit_current_per_mppt_a —
mppt_voltage_max_v 55
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
mppt_voltage_range_v 22~55V
nominal_ac_voltage 120V
nominal_frequency_hz —
number_of_mppt 1
number_of_pv_inputs —
phase_count 1
pv_input_voltage_max_v 60
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
pv_input_voltage_min_v 20
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
rated_ac_power_w 1200
startup_voltage_v 25
NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
units_per_branch —

Physical / mechanical

ac_terminal —
cooling —
dc_connector —
depth_mm —
dimensions_mm —
display —
enclosure_material —
height_mm —
mounting —
noise_db —
weight_kg —
width_mm —

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection NEMA 6
max_altitude_m —
operating_temperature_c -40 to +65
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app —
communication [] disputed
dry_contact —
meter_interface —
monitoring_portal —
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Warranty & service

conditions —
extension_options —
standard_years —

Documents

datasheet BDM-1200-LV specification sheet with UL certificates (250723) rev 250723
datasheet NEP BDM-1200-LV / BDM-1600-LV Microinverter Datasheet (250723)
manual NEP [EN_MANUAL] BDM-1200LV User Manual (Technical Data section) rev posted 2025-09
product-page BDM-1200-LV / BDM-1600-LV | NEP microinverters
product-page Microinverters | NEP - Northern Electric Power rev UNKNOWN
product_page NEP Europe BDM-1200-LV/BDM-1600-LV product page (technical data table, both model columns)

Recorded conflicts

max_input_current_per_input_a Review required
None — value currently stored in ANMA
25 — https://eu.northernep.com/proinfo/31.html
document-revision
ingress_protection Review required
NEMA 6 — value currently stored in ANMA
IP66/IP67 — https://northernep.com/wp-content/uploads/2025/09/%5BEN_MANUAL%5DBDM-1200LV%20User%20Manual.pdf
document-revision
startup_voltage_v Review required
25 — value currently stored in ANMA
24 — https://northernep.com/wp-content/uploads/2025/09/%5BEN_MANUAL%5DBDM-1200LV%20User%20Manual.pdf
document-revision
interfaces.communication Review required
[] — stored value
['PLC', 'Wi-Fi'] — incoming package
Detected during import wave8-saturation-2026-09-batch10

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

BDM-1200-LV UL-certs sheet, 'Recommended PV Module Max. Power' / 'Max. PV Current' / 'Start-up Voltage' / 'Rated AC Output Current'600 W x 3 / 25 A x 3 / 25 V / 10 A @ 120 V
BDM-1200LV User Manual mechanical/communication268 x 250 x 46.5 mm; 3.4 kg; PLC or Wi-Fi (2.4G); Night Power Consumption 110 mW
BDM-1200LV User Manual, 'AC Short Circuit Fault Current Over 3 cycles / Arms'15.3
BDM-1200LV User Manual, 'Max. Input Current / A'18 x 3
BDM-1200LV User Manual, 'Recommended PV Module Power Range / W'500 x 3
CEC Efficiency96.5%
Max PV current / No. of inputs25A×3 / No. of inputs: 3
Max. PV Current25 A × 3
Maximum short-circuit current (Isc)NOT PRINTED
NEP Europe efficiency rowsMax MPPT Efficiency 99.9%; Max Efficiency 97.5%
Number of PV inputs3 independent PV inputs
Rated AC Output Current10A
Recommended PV Module Max. Power600 W × 3
Sibling family for context: BDM-1200/1600/2000-WF QUAD manual'four independent DC input ports' / 'four sets of two oppositely sexed DC connectors'; 25A x 4 Isc; no tracker count
category index card titleBDM-1200-LV/BDM-1600-LV
withheld:ac.max_ac_power_w_detail"'Peak Output Power / VA 1200' from the BDM-1200LV User Manual."
withheld:ac.rated_ac_power_w_detail"1200 W, agreeing with ANMA."
withheld:dc.max_input_current_per_input_a25
withheld:dc.startup_voltage_v25
withheld:safety.ingress_protection"IP66/IP67"
withheld:safety.max_branch_current_a20
withheld:topology.max_units_per_ac_branch1
withheld:topology.max_units_per_ac_branch_detail"'Max. Units per 20A Branch 1' - a single unit fills a 20 A branch."
withheld:topology.mppt_independence_detail"NOT PUBLISHED. NEP Europe prints an explicit 'Number of Inputs' row (3 for the BDM-1200-LV) but no MPP-tracker count; the BDM-1200LV User Manual and the BDM-1200-LV UL-certs sheet were both re-read with a verbatim-quote prompt and neither states a tracker count either (the UL sheet's only MPPT rows